Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 12, 2011 FBO #3456
DOCUMENT

Y -- Electrical and Structural Repairs to Wharf F, PNBC Annex (Navy Yard), Philadelphia, PA. - Attachment

Notice Date
5/10/2011
 
Notice Type
Attachment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
N40085 NAVFAC MID-ATLANTIC Naval Facilities Engineering Command, Mid-Atlantic Code AQ, 9742 Maryland Avenue Norfolk, VA
 
Solicitation Number
N4008511R7254
 
Response Due
5/20/2011
 
Archive Date
6/3/2011
 
Point of Contact
Philip J. Cole (757) 341-1970
 
E-Mail Address
philip.j.cole@navy.mil
(philip.j.cole@navy.mil)
 
Small Business Set-Aside
N/A
 
Description
This project will provide for repairs to Wharf F electrical and structural repairs thereby insuring a return to customary operational level. Repairs consist of replacing the deck, piles, electrical components and structural element. This will enable the Wharf to accommodate the future and current berthing requirements of inactive vessels that Navy Inactive Ships maintenance Office (NISMO) will have berthed at PNY Annex. Demolition shall consist of the structure, pile caps and timber piles. The Wharf F shall be demolished to accommodate the driving of concrete piles and replacement of existing concrete deck with new pre-stressed concrete deck Pile supported Wharf shall be built to replace the existing Wharf F. The driving of these concrete piles shall be integral to the existing timber piles. A concrete pile cap and concrete decking for each weight handling equipment in loading/unloading areas shall be repaired according to standard civil engineering practices with various sized rebar framing. The UFC 4-152-01, "Piers and Wharves" provide minimum facility planning and design criteria for efficient home porting facilities of Naval Vessels. All design criteria efforts shall follow ACI, AISC and AF7PA Codes to complete a safe and efficient structure. Mooring hardware is in poor condition requiring repair or repair by replacement and therefore shall be demolished with the existing structure. Electrical work shall consist of a ship to shore stations, necessary transformers along with associated breakers and cabling.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N62470HR/N4008511R7254/listing.html)
 
Document(s)
Attachment
 
File Name: N4008511R7254_N40085-11-R-7254_SourcesSought_RM189-08.docx (https://www.neco.navy.mil/synopsis_file/N4008511R7254_N40085-11-R-7254_SourcesSought_RM189-08.docx)
Link: https://www.neco.navy.mil/synopsis_file/N4008511R7254_N40085-11-R-7254_SourcesSought_RM189-08.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: PNBC Annex (Navy Yard), Philadelphia, PA
Zip Code: 19112
 
Record
SN02444418-W 20110512/110510234923-766b004fcbdb931cb17aa6ccab7c0480 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.