SPECIAL NOTICE
Y -- Please see the admendment to the Presoliciation Notice/Synopsis W912LC-11-R-0001
- Notice Date
- 2/15/2011
- Notice Type
- Special Notice
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- USPFO for Colorado, ATTN: Mail Stop 53, 660 South Aspen Street, Building 1005, Aurora, CO 80011-9511
- ZIP Code
- 80011-9511
- Solicitation Number
- W912LC-11-R-0001
- Response Due
- 3/22/2011
- Archive Date
- 5/16/2011
- Point of Contact
- daniel.j.pagone, 720 847 8679
- E-Mail Address
-
USPFO for Colorado
(daniel.j.pagone@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- Amendment to Synopsis of Solicitation W912LC-11-R-0001 This Amendment to the Synopsis of Solicitation W912LC-11-R-0001 is hereby added in full The Government has the following Optional Line Items (OLI) listed below. The Government reserves the right to exercise these Optional Line Items according to the terms of the Solicitation. Option 1: Provide 4 stories of billeting rooms in Area 1. 12 rooms per floor for a total of 48 billeting rooms. Option 2: Provide 4 stories of billeting rooms in Area 2. 8 rooms per floor for a total of 32 billeting rooms. Option 3: Provide 4 stories of billeting rooms in Area 4. 8 rooms per floor for a total of 32 billeting rooms. Option 4: Provide a complete and fully functional Guard House with associated site components. Option 5: Provide a complete Direct Digital Control (DDC) for the billeting rooms provided under the Base Line Item. Option 5a: If OLI 1 and OLI 5 are accepted by the Government, provide a complete Direct Digital Control (DDC) for the billeting rooms provided under the OLI 1. Option 5b: If OLI 2 and OLI 5 are accepted by the Government, provide a complete Direct Digital Control (DDC) for the billeting rooms provided under the OLI 2. Option 5c: If OLI 3 and OLI 5 are accepted by the Government, provide a complete Direct Digital Control (DDC) for the billeting rooms provided under the OLI 3. Option 6: Provide a 600kW/750kVA Prime Rated engine-generator set and associated accessories in lieu of the 500kW/650KvA Standby Rated engine generator set. Deduct load-shedding devices provided under the Base Line Item
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/NGB/DAHA05/W912LC-11-R-0001/listing.html)
- Record
- SN02380672-W 20110217/110215234643-f32a2256ed4c54f249f8d029d37e3a14 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |