SOLICITATION NOTICE
41 -- Replace (12) Non-CLA HVAC Units - Solicitation
- Notice Date
- 10/15/2010
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 333415
— Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Contracting Office
- Department of the Army, U. S. Army Materiel Command, Anniston Chemical Agent Disposal Facility (ANCDF), 3580 MORRISVILLE ROAD, Anniston, Alabama, 36201, United States
- ZIP Code
- 36201
- Solicitation Number
- ANCDF-RFQ-W10-2546
- Archive Date
- 11/19/2010
- Point of Contact
- Ashley Rollins, Phone: 256-238-0721 x 131
- E-Mail Address
-
ashley.rollins@wancdf.com
(ashley.rollins@wancdf.com)
- Small Business Set-Aside
- N/A
- Description
- Solicitation •§ Certified contractor to perform the replacement of HVAC units for buildings located outside of the CLA. The replacement HVAC units shall be provided by ANCDF to the subcontractor. •§ Contractor to provide all labor and materials to replace Non-CLA HVAC units. •§ This scope shall include any re-wiring or re-routing of the electrical service to each unit as necessary to provide power to the units including the materials required for that effort. •§ The PVC condensate drains from each unit, where currently installed, shall be maintained or restored to current functionality and appearance. •§ The metal siding of the buildings and the interior of the buildings shall be maintained or restored as necessary to maintain a presentable appearance upon completion. •§ Contractor shall be responsible for recovering refrigerant from old units for disposition. •§ Contractor shall be responsible for proper disposition of old units. •§ All work shall be performed to applicable codes and professional standards with proper and current licensing and certification. The non-CLA units to be replaced are as followed: Number AC Unit Tag Number Description Model 1 03-PSB-HVAC-117-SC BARD exterior wall mount self contained A/C unit R-410A W36A1-A10XXXXXE 2 03-PSB-AIRH-901-SC Sanyo Duct Free Split A/C unit R-410A C2672R (Outdoor) KHS2672r (Indoor) 3 03-BIZOP-HVAC-003-SC BARD exterior wall mount self contained A/C unit R W48A1-A10XXXXXE 4 03-BIZOP-HVAC-004-SC BARD exterior wall mount self contained A/C unit R W48A1-A10XXXXXE 5 03-MLF-HVAC-001-SC BARD exterior wall mount self contained A/C unit R-410A W36A1-A10XXXXXE 6 03-WA-HVAC-006-SC BARD exterior wall mount self contained A/C unit R-410A W36A1-A10XXXXXE 7 03-WA-HVAC-007-SC BARD exterior wall mount self contained A/C unit R-410A W36A1-A10XXXXXE 8 03-PMOC-AIRH-900-SC Sanyo Duct Free Split A/C unit R-410A C3672R (Outdoor) KHS3672R (Indoor) 9 03-OSOANNEX-HVAC-001-SC BARD exterior wall mount self contained A/C unit R-410A W36A1-A10XXXXXE 10 03-OSOANNEX-HVAC-002-SC BARD exterior wall mount self contained A/C unit R-410A W36A1-A10XXXXXE 11 03-OSO-HVAC-003-SC BARD exterior wall mount self contained A/C unit R W48A1-A10XXXXXE 12 03-OSO-HVAC-004-SC BARD exterior wall mount self contained A/C unit R W48A1-A10XXXXXE The work order will have the following information included: •§ Include ANCDF Lift Plan Form MNT-4.01-0001FRM.R001 in work order. •§ Include Attachment Property Disposition Request Form PROP-14.01-001.FRM.R001 in work order. •§ Adhere to Work Control Program MNT-2.01. •§ Follow LO/TO (Lockout/Tagout) Procedure SAF-2.25. Work order activities will include: •1. LO/TO AC Unit to be replaced. •2. Obtain ANCDF provided replacement AC unit from ANCDF designated storage area. •3. Disconnect power wiring, control wiring and condensate drain connection (where applicable). •4. Remove existing AC unit. •5. Install new AC unit provided by ANCDF. •6. Re-connect power wiring, control wiring and condensate drain connection (where applicable). •7. Restore metal siding of the buildings and the interior of the buildings to pre-replacement condition and to maintain a presentable appearance upon completion. •8. Ensure units are fully ready for operation (filters installed, thermostat correctly wired, control power set to correct tap voltage, no obvious signs of physical damage, etc.). •9. Remove LO/TO. •10. Perform PMT (post maintenance testing) to ensure proper AC operation. During PMT, note, record and report any and all deficiencies on Subcontractor Daily Report. •11. Recover refrigerant from old units for disposition preparation. Properly label with Refrigerant Removal Tag. •12. Disposition old AC unit to specified location with properly completed paperwork.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/f52064d8648ffc053b9487a911aaf1ed)
- Place of Performance
- Address: 3580 Morrisville Road, Anniston, Alabama, 36201, United States
- Zip Code: 36201
- Zip Code: 36201
- Record
- SN02311671-W 20101017/101015233743-f52064d8648ffc053b9487a911aaf1ed (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)