SOLICITATION NOTICE
65 -- digital ultrasound equipment and accessories
- Notice Date
- 9/21/2010
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- Department of Veterans Affairs;North Texas Veterans Health Care Center;4500 S. Lancaster Road;Dallas TX 75216
- ZIP Code
- 75216
- Solicitation Number
- VA25710RQ0403
- Response Due
- 9/24/2010
- Archive Date
- 9/29/2010
- Point of Contact
- Lynn Pettit
- E-Mail Address
-
ettit@va.gov<br
- Small Business Set-Aside
- Total Small Business
- Description
- The Department of Veterans Affairs, VA North Texas Health Care System (VANTHCS), Dallas, TX has a requirement for a digital ultrasound machine with an imaging probe. VANTHCS requires brand name or equal to the Sonosite M-Turbo 1.3 (with accessories). The contractor shall provide as part of the firm fixed price: installation, training and warranty. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, in conjunction with FAR 13.5 and 19.5, as applicbale, and as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. Proposals are being requested and a written solicitation will not be issued. Solicitation number is VA-257-10-RQ-0403 and is issued as an RFQ. The acquisition is solicited as total set aside for small business for NAICS 334510, 500 employees. Only qualified and responsible sources may submit a quotation. The Department of Veteran Affairs, VA North Texas Health Care System, VISN 17 requires the following items, Brand name or equal, quantity of 1 each: L05323 “ M-Turbo 1.3 P07271 - M-Turbo color Option -Olympic Mist P08592 - Standard Application Software Package M-Turbo P08293 - Color Doppler and Velocity Color P13269 - MSK Worksheets P08298 - Clips Storage P07693 - HFL50x/15-6 MHZ Transducer Biopsy Compatible PO7680 - C60X/ 5-2 MHZ Transducer Biopsy Compatible L12163H - Universal Stand P12819 - DICOM Bundle M-Turbo L00016 - SONY UP 897 MD Black and White video printer P04764 - Connect with quick disconnect SPECIFIC REQUIREMENTS 1. A high resolution, digital ultrasound system with at least a 10 ¯ digital display with 8GB memory that can retain over 40 scans with software that has Tissue Harmonic Imaging (THI), a capability in which the system transmits at one frequency and receives at a higher harmonic frequency to reduce noise and clutter and improve resolution. System should include Broadband, multi-frequency imaging, which is required with 2D / Tissue Harmonic Imaging. 2. Velocity color doppler, color power, and tissue dopplers are required. 3. Image processing should include tissue optimization, high level imaging technology, and multi-beam technology. 4. The transducers (or probes) should be Broadband and multi-frequency and include: linear array, curved array, phased array, multi-plane transesophageal echocardiogram, and Micro-Convex. C60x / 5-2 MHz multi-frequency, broadband, 60 mm curved array transducer for general purpose, abdominal, obstetric, gynecology, and nerve exams. HFL50x / 15-6 MHz multi-frequency, broadband, 50mm linear array transducer for small parts, breast, and musculoskeletal that supports 2D machines. 5. A single frequency cardiac static pencil is required. 6. A three-transducer module for mobile docking that allows connection up to 3 transducers simultaneously is required. 7. A complete rolling universal stand with power supply and DVI mini-dock. Requires isolation transformer base and mounts or kit. 8. The software is required to have the capability to interface with the PACS network, with the complete offering of DICOM Print, Store, Worklist, storage commit, and modality perform procedure step. 9. A medical grade, monochrome video printer and interface cables are required. New equipment only. No remanufactured or gray items. All items must be covered by manufacturer ™s warranty. No partial shipments are permitted. Delivery date shall be no more than 30 days from date of award. Place of Delivery: VA North Texas Health Care System, 4500 S. Lancaster Rd., Warehouse, Building 44, Dallas, TX 75216 The selected offeror must comply with the following commercial item terms and conditions, which are incorporated herein by reference: FAR 52.212-1 - Instructions to Offerors “Commercial Items, FAR 52.212-3 “ Offeror Representations and Certifications “ Commerical Items- selected offeror must submit a completed copy of the listed representation and certifications, FAR 52.212-4, Contract Terms and Conditions “ Commercial Items, FAR 52.212-5, Contract Terms and Conditions - Required to Implement Statutes or Executive Orders “ Commercial Items, paragraph (b) 52.204.10, 52.219-28, 52.222-3, 52.222-19, 52.222-21, 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.225-1, 52.225-3 52.225-13, 52.232.34, VAAR 852.246-70 - Guarantee, 852-246-71 “ Inspection, 852-211-73 Brand Name or Equal, 852-211-70 - Service Data Manuals, 852-203-70 Commercial Advertising. The full text of FAR VAAR Clauses may be accessed electronically at http://www.acquisition.gov/far/index.html http://www.va.gov/oamm/oa/ars/policyreg/vaar/index.cfm Shipping must be free on board (FOB) destination CONUS (Continental US). The seller must deliver the goods on its conveyance to the destination specified by the buyer. The seller is responsible for the cost of shipping and risk of loss prior to actual delivery to the specified destination. Quotations will be accepted beginning on the date this solicitation is posted and will end on 9-24-1010 12PM CST. Interested offerors must submit any questions concerning this solicitation by electronic mail to Lynn Pettit at Lynn.Pettit@va.gov.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANTHCS/VANTHCS/VA25710RQ0403/listing.html)
- Record
- SN02291236-W 20100923/100921235805-bdd36ff866c3c6bbe4e35e918511e996 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |