SPECIAL NOTICE
41 -- Cleveland 24CEA10 Electric kitchen Steamer
- Notice Date
- 9/7/2010
- Notice Type
- Special Notice
- NAICS
- 423740
— Refrigeration Equipment and Supplies Merchant Wholesalers
- Contracting Office
- Fort Myer DOC, Bldg 205, Room 213, 204 Lee Avenue, Fort Myer, VA 22211-1199
- ZIP Code
- 22211-1199
- Solicitation Number
- W91QF7-10-T-0191
- Archive Date
- 12/6/2010
- Point of Contact
- mohamed.h.abdelghany, 703-696-7063
- E-Mail Address
-
Fort Myer DOC
(mohamed.h.abdelghany@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- REQUEST FOR QUOTATION The Mission and Installation Contracting Command-Myer Directorate of Contracting has a requirement to Cleveland 24CEA10 Electric kitchen Steamer on Fort McNair, Washington, D.C. This is a combined synopsis / solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This procurement is a small business set-aside; any responsible source may submit an offer. This announcement constitutes the only solicitation; quotes are being requested and a separate written solicitation will not be issued. Solicitation number W912PQ-10-T-0191 applies and is issued as a Request for Quotation. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-13 and Defense Acquisition Circular 91-13. The applicable North American Industry Classification System (NAICS) code is 423740 with a size standard of 100 employees. Please see the attached ITEM LIST for the agency need. All interested parties shall submit clear and convincing documentation demonstrating the capabilities to satisfy the requirement listed below to Mr. Mohamed Abdelghany via email at Mohamed.h.Abdelghany @us.rmy.mil or fax to (703) 696-7063, or by mail at the following address: 101 Bloxon stree STE 213A BLDG 205, Fort Myer,VA 22211. All responses are due by 12 PM (Eastern Standard Time) on Thursday, September 9, 2010. Performance Statement of Work Cleveland 24CEA10 Electric kitchen Steamer Fort McNair, Washington, D.C. Project: Kitchen Steamer Location: Building 64, National Defense University, Ft. McNair, DC Work Request: AC-01902-0J SCOPE OF WORK: The scope of the project is limited to procurement of the electric steamer, electric kettle and related accessories. The scope does not include installation of the equipment and providing the power supply, and other accessories to make the units completely tested and being functional. Notify project manager (PM) as soon as the electric steamer and electric kettle are procured. The contractor shall perform a site visit to note all as-built construction particulars pertaining to this project and verify proposed units will meet the needs of the facility. Provide the equipment based on the following criteria: 1.Convection electric steamer, floor model Cat # Cleveland Range Inc, Model #24CEA10 or approved equal. It shall include the following: a.Steamcraft Gemini 10, Pressureless Steamer, electric, 2 compartments with individual generators, (5) 12X20X2 pans/compartment capacity, electro-mechanical 60 minute timers, s/s construction, 6 s/s legs, twin 16kw, total 32kw. b.One year limited warranty, standard c.(2) 16.5kw steam generators standard d.(VOS2) 480v/60/3-ph, 39.8 amps, 3-wire e.9797-21 Kleensteam II, Water Filter Assembly, for floor model steamers, includes (1) CV cartridge, (1) AR-10 filter cartridge, dip tube & ScaleKleen 2.2-lb packet, wall-mounting bracket & gauge assembly 2.Electric Kettle, Table Top Cat # Cleveland Range Inc, Model #TKET-12-T or approved equal. It shall include the following: a.Kettle, Electric, Table Top, twin 12 gallon capacity, tilt type, center support console, two-thirds steam jacket, stainless steel construction b.One year limited warranty, standard c.Standard wattage d.(VOK2) 480v/60/3-ph, 26.1kw, 31.4 amps e.DPKT Double Pantry Faucet, with swing spout & mounting bracket for tilting kettles f.ST55T Equipment Stand, open base with sliding drain drawer & splash screen, 55X26, 18 high, stainless steel top and legs, allows unit to be hard piped to a floor drain. Provide labor and materials to repair walls, floors and other surfaces damaged due to the work performed under this work request. All damaged areas shall be restored to meet or exceed facility standards. Notes: All construction shall comply with the NEC (National Electric Code) and applicable building codes.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/f8e593c1fd838c5f0e81572e2a4dedaf)
- Record
- SN02270682-W 20100909/100908063015-f8e593c1fd838c5f0e81572e2a4dedaf (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |