MODIFICATION
Y -- Construction of Structures and Facilities
- Notice Date
- 7/13/2010
- Notice Type
- Modification/Amendment
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- N40085 NAVFAC MID-ATLANTIC Naval Facilities Engineering Command, Mid-Atlantic Code AQ, 9742 Maryland Avenue Norfolk, VA
- ZIP Code
- 00000
- Solicitation Number
- N4008510R5329
- Response Due
- 7/29/2010
- Archive Date
- 8/13/2010
- Point of Contact
- Ray Hinman 757-322-8398
- Small Business Set-Aside
- N/A
- Description
- THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSALS. THERE WILL NOT BE A SOLICITATION, SPECIFICATIONS, OR DRAWINGS AVAILABLE AT THIS TIME. The Naval Facilities Engineering Command, Mid-Atlantic is seeking small eligible business firms capable of performing requirements for Bachelor Enlisted Quarters (BEQs), Courthouse Bay. Project numbers are P-1251 and P-1254. All construction work will be accomplished at Camp Lejeune, NC MCB. DESCRIPTION OF WORK: Project Number 1251: Construct two 100 room multi-story bachelor enlisted quarters (BEQs) with interior and exterior concrete masonry unit walls on pile foundations with structural steel framing, reinforced masonry walls, brick veneer, reinforced concrete foundation and floors, and standing seam metal roofs. Built-in equipment for each BEQ building includes: Americans with Disabilities Act compliant passenger/freight elevator, fire pump with generator backup, spectrally selective window glazing, energy monitoring control system, and a mass notification system. Information systems include telephone, local area network, and NGEN support in each BEQ. Electrical utilities include: electrical distribution and fire alarm system. Mechanical utilities include: water distribution, fire protection system, and HVAC. Supporting facilities include: site lighting; paved parking and roadways; sidewalks; miscellaneous concrete pads; staging and drying area for field equipment; stormwater retention pond; clearing and grubbing; earthwork; building and roadway signage; landscaping; and an upgrade of a portion of the Amphibious Assault Vehicle (AAV) trail near the project site. The project also includes operation and maintenance support information and environmental mitigation. Project Number 1254: Construct two 100 room multi-story bachelor enlisted quarters (BEQs) with interior and exterior concrete masonry unit walls on pile foundations with structural steel framing, reinforced masonry walls, brick veneer, reinforced concrete foundation and floors, and standing seam metal roof. Built-in equipment for each BEQ building includes: Americans with Disabilities Act compliant passenger/freight elevator, fire pump with generator backup, spectrally selective window glazing, and energy monitoring control system. Electrical systems include: power, lighting, and fire alarm. Mechanical systems include: plumbing, fire protection, and HVAC. Information systems include telephone, data, local area network, voice and data communication, and mass notification. This project will require NGEN support in each BEQ building. Supporting facilities include: site lighting, paved parking and roadways, sidewalks, miscellaneous concrete pads, staging and drying area for field equipment, stormwater management system, clearing and grubbing, earthwork, access roads, lighted basketball and volleyball courts, picnic shelter and barbecue pit, landscaping, and building and roadway signage. Site utility distribution systems include: electrical power, domestic water, fire protection water, sanitary sewer, stormwater management, steam, fire alarm, telephone communication, fiber optics, and cable television. The project will conform to anti-terrorism/force protection standards and follow LEED and Federal Energy Acts compliance criteria for design, development, and construction of the project. Low Impact Development will be included in the design and construction of this project. This project includes operation and maintenance support information, environmental mitigation, and Geospatial Data Survey and Mapping. Project Number 1255 (Option FY12): CANCELLED These projects will conform to anti-terrorism/force protection standards and follow LEED and Federal Energy Acts compliance criteria for design, development, and construction of the project. Low Impact Development will be included in the design and construction of this project. All service-disabled veteran-owned small businesses certified HUBZone, small businesses and certified 8a small business are encouraged to respond. Upon review of industry response to this notice, the Government will determine whether a set-aside acquisition in lieu of full and open competition is in the Governments best interest. This is a market research tool being used to determine the availability and adequacy of potential small business sources prior to determining the method of acquisition and issuance of an award. The Government is not obligated to and will not pay for any information received from potential sources as a result of this synopsis. It is requested that interested small businesses submit to the contracting office a brief capabilities statement package (no more than 25 pages in length, single-spaced, 12-point font minimum) demonstrating ability to perform the requested services. This documentation shall address, as a minimum the following: (1) Relevant Experience to include experience in performing efforts of similar size, scope and complexity within the last five years, including contract number, indication of whether a prime or subcontractor, contract value, Government/Agency point of contract and current telephone number, and a brief description of how the contract referenced relates the technical services described herein; (2) Company Profile, to include number of employees, office location(s), available bonding capacity up to $83,000,000.00, DUNS number, CAGE code, and statement regarding small business designation and status. RESPONSES ARE DUE, THURSDAY, JULY 29, 2010 BY 2:00 PM. LATE RESPONSES WILL NOT BE ACCEPTED. The package shall be sent by mail to the following address: Commander Naval Facilities, Mid-Atlantic, North Carolina IPT (ATTN: Ray Hinman); 6506 Hampton Blvd., Bldg. C, Room 1036; Norfolk, VA 23508. Electronic submission of the Statement of Capabilities Packages WILL NOT be accepted. Questions or comments regarding this notice may be addressed via e-mail to Ray Hinman, e-mail: ray.hinman@navy.mil, Tele: 757-322-8398.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N62470HR/N4008510R5329/listing.html)
- Record
- SN02204131-W 20100715/100713235127-fb3bb1e162d634f871d791bab679e2c6 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |