SOLICITATION NOTICE
43 -- ROTARY SCREW AIR COMPRESSORS
- Notice Date
- 7/7/2010
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 333912
— Air and Gas Compressor Manufacturing
- Contracting Office
- USACE District, Vicksburg, ATTN: CEMVK-CT, 4155 Clay Street, Vicksburg, MS 39183-3435
- ZIP Code
- 39183-3435
- Solicitation Number
- W912EE-10-T-0054
- Response Due
- 7/21/2010
- Archive Date
- 9/19/2010
- Point of Contact
- Brian T. Gladney, 6016315812
- E-Mail Address
-
USACE District, Vicksburg
(brian.t.gladney@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. Solicitation No. W912EE-10-T-0054 is being issued as a Request For Quote (RFQ) with the intent to award as a simplified acquisition. The solicitation will be competed Un-restricted and evaluated based on Rotary Screw Air Compressor compatibility with the following specifications for name brand or equal. The solicitation document and incorporated provision and clauses are those in effect through Federal Acquisition Circular 2005-42. The NAICS Code for this procurement is 333912 (SIC 3563) with a size standard of 500 employees. The U.S. Army Corps of Engineers (USACE), Vicksburg District has a requirement for (2) AIR COMPRESSORS similar or equal to INGERSOLL RAND UPS-50 125PSI ROTARY SCREW AIR COMPRESSOR in accordance with the Specifications: The two air compressors shall be equal to or similar to the Ingersoll Rand UP6050PE SSR Rotary Screw Air Compressor. The Ingersoll Rand is used as an example or illustration only. It may not be purchased because it is manufactured by a large business and the Rotary Screw Air Compressors to be purchased must be manufactured by a small business as stated in FAR 19.502-2(c). All following specifications must have an Outdoor Modification Option. This will increase the reliability and life of the machines extensively. This option includes NEMA 4 plus additional enclosure panels at the cooling air entrance and exit to prevent water from entering the compressor cabinet. A FULL NEMA 4 PACKAGE must be included. This combination option is intended for those installations requiring protection from dust and/or high humidity. This option includes: NEMA 4 starter cabinet, NEMA 4 control panel, NEMA 4 solenoids and conduit, TEFC main motor, TEFC cooling fan motor, Star-delta starter. The following specifications are critical: 50hp 230/460 volt, 3 phase, 60 hertz, totally enclose fan cooled motor/NEMA 4 controls, 208cfm @125 psi or greater, Low sound enclosure, Ultra coolant, Moisture separator, Dimensions (LxWxH) 67.4 x 54.3 x 52.8 same or smaller, Low sound enclosure (69 dba), Connection Size 1.5 in. The following shall be included in this procurement: Each unit shall be crated for shipping, Delivery to Monroe, La., After installation, a Company representative shall insure proper start up and operation of each unit located at (1)Columbia Lock and Dam &(2)Jonesville Lock and Dam on the Ouachita/Black River in Northern La. These locations may be located as follows: See (Attachment 1), Map of unit delivery locations. The full text of a FAR provision or clause may be accessed electronically at www.farsite.hill.af.mil. The following provisions apply to this acquisition: 52.212-1, Instructions to Offerors-Commercial Items; 52.212-3 Offerors Representations and Certifications- Commercial Items. The following clauses apply to this acquisition: 52.212-4 Contract Terms and Conditions Commercial Items. 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Commercial Items: And the following clauses/provisions within 52.212- 5: 52.219-8 Utilization of Small Business Concerns; 52.222-3 Convict Labor; 52.222-19 Child Labor Cooperation With Authorities And Remedies; 52.222-21 Prohibition of Segregated Facilities; 52-222-26 Equal Opportunity; 52.222-35 Equal Opportunity for Special Disabled Veterans; 52.222-36 Affirmative Action for Workers with Disabilities; 52.222-37 Employment Reports on Special Disabled Veterans, Veterans of the Vietnam Era, and Other Eligible Veterans; 52.222-39 Notification of Employee Rights Concerning Payment of Union Dues or Fees; 52.225-13 Restriction on Certain Foreign Purchases and 52.232-33 Payment by Electronic Funds Transfer-Central Contractor Registration. The following Clauses are also applicable to this acquisition: DFARS 252.204-7004 ALT A, Central Contractor Registration; DFARS 252.212-7000 Offeror Representations and Certifications--Commercial Items; 252.212-7001, Contract Terms and Conditions Required to Implement Statues or Executive Orders applicable to Defense Acquisitions of Commercial Items; 252.232-7010 Levies on Contract Payments. Quotes are due 21 July 2010 not later than 2:00 p.m. at the USACE VICKSBURG DISTRICT, 4155 CLAY STREET, VICKSBURG, MS 39183-3435, ATTN: Brian T. Gladney. For information concerning this solicitation contact Brian T. Gladney at 601-631-5812 or email at Brian.T.Gladney@usace.army.mil. All technical inquiries and questions relating to W912EE-10-T-0054 are to be submitted via Bidder Inquiry in ProjNet at http://www.projnet.org/projnet. To submit and review bid inquiry items, bidders will need to be a current registered user or self-register into system. To self-register go to web page, click BID tab select Bidder Inquiry, select agency USACE, enter Key for this solicitation listed below, and your e-mail address, click login. Fill in all required information and click create user. Verify that information on next screen is correct and then click continue. From this page you may view all bidder inquiries or add inquiry. Bidders will receive an acknowledgement of their question via email, followed by an answer to their question after it has been processed by our technical team. The bidder inquiry key is LY75S4-MIFWZ1. Bidders are encouraged to submit questions at least 5 days prior to the closing/response date of the solicitation in order to ensure adequate time is allotted to form an appropriate response and amend the solicitation, if necessary. Bidders/Offerors are requested to review the specification in its entirety, review the Bidder Inquiry System for answers to questions prior to submission of a new inquiry. For Help with the ProjNet System; the call center operates weekdays from 8AM to 5PM U.S. Central Time Zone (Chicago). The telephone number for the Call Center is 800-428-HELP.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA38/W912EE-10-T-0054/listing.html)
- Place of Performance
- Address: USACE District, Vicksburg ATTN: CEMVK-CT, 4155 Clay Street Vicksburg MS
- Zip Code: 39183-3435
- Zip Code: 39183-3435
- Record
- SN02197737-W 20100709/100707234545-d71e981ad4d57f25c6a7b3860bdeff75 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |