Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 16, 2010 FBO #3126
SOLICITATION NOTICE

Z -- North-West Power Extension - W91B4K-10-R-7067

Notice Date
6/14/2010
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
237130 — Power and Communication Line and Related Structures Construction
 
Contracting Office
Department of the Army, Joint Contracting Command, Iraq/Afgahnistan, FENTY RCC (JALALABAD), APO AE, Non-U.S., 09310, Afghanistan
 
ZIP Code
00000
 
Solicitation Number
W91B4K-10-R-7067
 
Archive Date
7/10/2010
 
Point of Contact
Robert A. Cody, Phone: 0793585448, Richard R. Bremer, Phone: 0797664063
 
E-Mail Address
robert.a.cody@afghan.swa.army.mil, richard.bremer@afghan.swa.army.mil
(robert.a.cody@afghan.swa.army.mil, richard.bremer@afghan.swa.army.mil)
 
Small Business Set-Aside
N/A
 
Description
SOLICITATION WITH SOW AND DRAWINGS Requirement The work consists of providing and installing (2) 500kVA transformers, (1) 3Way Sectionalizer, and a (2) 1200amp I-Line Panel and all applicable cabling. The cabling will connect via load break elbows to the existing Primary Switching Center located near the northwest corner of the runway. The cable will run Northwest direct buried crossing under the road through contractor provided conduit and continue running direct buried until reaching the south end of the Contractor Working Dog Compound area. Here (1) 500kVA transformer shall be placed and connected via load break elbows in and out of the transformer. From the transformer(1) 1200amp I-Line panel will be placed and connected. Cabling will then run northwest again until reaching the bridge. At that point the cable will run through contractor provided 6" conduit elbows (incased in concrete) into existing conduit and continue northwest direct buried after exiting the bridge through contractor provided 6"conduit elbows (incased in concrete) until reaching the south edge of the Civil Military Operations compound. Here (1) 3Way Sectionalizer will be placed and connected using load break elbows in and out of the sectionalizer. Cable will then continue running direct buried northwest to the south edge of the parking area. In this area (1) 500kVA transformer will be placed and connected using load break elbows. From the transformer (1) 1200amp I-Line panel will be placed and connected. Additional Information To assure timely and equitable evaluation of proposals, offerors must follow the instruction contained herein. Proposals must be complete, self-sufficient, and respond directly to the requirements of this solicitation. Offerors shall assume that the Government has no prior knowledge of their experience, and will base its evaluation on the information presented in the Offeror's proposal. Part I -Price Proposal Part II - Technical Proposal Part III - Past Performance Information BOTH HARD COPY AND ELECTRONIC PROPOSALS WILL BE ACCEPTED. Hard copy proposals must be dropped off at the Fenty bid drop box located at the Entry Control Point. Electronic file submissions must not exceed 4.5MB in size. All proposals must be received by the contracting office no later than the offeror due date and time listed in block 8 of the SF 1449. The anticipated contract type is Firm-Fixed Price. Period of Performance is 120 calendar days after receipt of the Notice to Proceed. Submittal of questions will be open until 19 June 2010 at 12:00 PM local time (Afghanistan). No questions will be taken after the specified date and time. The North American Industry Classification System (NAICS) code for this procurement is 237130, Tower, Power Distribution and Communication, Construction. The successful Contractor will be selected utilizing lowest price technically acceptable (LPTA) source selection procedures in accordance with FAR 15.101-2. If the lowest priced proposal is found to be unacceptable, the next lowest priced offer will be reviewed, and so on, until one is found to be technically acceptable. To be found technically acceptable the offer must meet all of the specifications listed in the solicitation. The solicitation MUST be downloaded from Federal Business Opportunities (FedBizOpps) at www.fbo.gov. Do not request via fax or mail. No paper copies will be issued. It is important to check this site frequently for any updates/amendments.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/26f4c1cb399c973a4ffc0bb452cc60a9)
 
Place of Performance
Address: FOB - FENTY - JALALABAD AIRPORT, APO AE 09310, Afghanistan
 
Record
SN02177146-W 20100616/100614234909-26f4c1cb399c973a4ffc0bb452cc60a9 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.