SOURCES SOUGHT
65 -- SYSTEM WITH HEAT SANITIZABLE REVERSE OSMOSIS MACHINE
- Notice Date
- 4/29/2010
- Notice Type
- Sources Sought
- NAICS
- 333319
— Other Commercial and Service Industry Machinery Manufacturing
- Contracting Office
- Department of Veterans Affairs;Brecksville Division;Cleveland VA Medical Center;10000 Brecksville Road;Brecksville Brecksville 44141
- ZIP Code
- 44141
- Solicitation Number
- VA-250-10-RQ-0162
- Response Due
- 5/14/2010
- Archive Date
- 7/13/2010
- Point of Contact
- Glen JohnsonContract Specialist
- E-Mail Address
-
P.O.C.
(Glen.Johnson@va.gov)
- Small Business Set-Aside
- N/A
- Description
- Date: 4/27/2010Closing Date: 5/14/2010 at 9am (Local Time) RFI (Seeking Sources Only) From: VISN 10 Contracting Activity 10000 Brecksville Road Brecksville, Ohio 441 41 The Louis Stokes Cleveland Veterans Affairs Medical Center (LSCVAMC) is seeking potential sources for the purchasing and installation of a Reverse Osmosis Water Treatment System. The proposed North American Industry Classification System (NAICS) is 333319, Other Commercial and Service Industry Machinery Manufacturing, and size standard is 500. Responders should identify if they are a small business or small disadvantaged business concern, based on this NAICS code. A general statement of work is provided on pages 2 and 3 of this notice. This is not a solicitation announcement. The purpose of this RFI is to gain knowledge of potential qualified sources. Responses to this notice shall be e-mailed. Other supporting material may be mailed or faxed to the attention of Glen Johnson 90(C), VISN 10 Contracting Activity, 10000 Brecksville Rd, Brecksville, OH, 44141. E-mail address is Glen.Johnson@va.gov; Fax: 440-838-6052. Telephone inquires will not be accepted. Responses must be received in writing no later than Friday, May 14, 2010 at 9am (Local Time). Response to this RFI is not considered adequate responses to any future solicitation announcements. Response to this RFI is not a request to be added to a prospective bidders list or to receive a copy of future solicitations. LINE ITEMDESCRIPTIONQUANTITY 1"Water Tempering Valve with Built-In Cold Water By-Pass and Analog Temperature Gauge1 2"Depth Filter for Particle Removal with By-Pass oCartridge 5 Micron1 3"Exchangeable Carbon Tanks Sized for 10 Minute Empty Bag Contact Time1 4"Softener Tank Sized to Remove 12 Grains Per Gallon1 5"Brine Tank for Softener Tank1 6"5 Micron Pre-RO Filter1 7"Dual Alternating Reverse Osmosis Unit oHeat Disinfect Tolerant 8"200 - 250 gallon storage tank for RO Unit oHeat disinfect tolerant 9"Distribution Pumps oDuel Alternating oSized 3 Feet Per Second oMulti Staged oHeat Disinfect Tolerant2 10"Flow Switches for Pump Protection1 11"DI Manifold Plumbed with By-Pass oDry DI tanks as standby oSize minimal 12 hours of operation based a incoming water analysis of1 12"Ultra-Filtration for Endo-Toxin Removal oHeat disinfect tolerant1 13"Resistivity for DI Tanks oDigital readout monitor oRevert to drain dump value for poor water quality1 14"Distribution Loop oPFA Teflon Piping o3 Feet Per Second Flow velocity oFlow Meter at Beginning and End of Distribution Loop1 15"Recessed Dialysis wall box oSeven (7) in treatment room oOne (1) in repair room oWater hookup shutoff valve oTreated water to wall box oFittings to be compatible with the Fresenius 2008K Dialysis Machine oTwo (2) dialysis machine water connections in water treatment room8 16"Bicarb Mixer o50 Gallon Tank1 17"Remote Monitor Box in Patient Treatment Room1 18"Water Connections1 19"Installation1 20"Testing oMust meet AAMI Standards oMust meet FDA Class II Medical Device Requirements1 21"Training oOverview/ Operation with Dialysis Staff oTo be Coordinated with Chief Tech1 The Reverse Osmosis Water Treatment System will be installed in the near future, with the exact date to be determined once an award is made and the corresponding construction project contractor submits a construction schedule. The Reverse Osmosis Water Treatment System will be tested before acceptance and payment. ADDITIONAL REQUIREMENTS: Following are the additional requirements: 1)Installation must be coordinated with construction contractor, VA Engineering Service and Dialysis Staff. 2)A Site Specific Safety Plan (SSSP) will be required to be submitted after ten (10) days after award and approved before work can begin. 3)Shop drawings well need to be submitted for review and approved by LSCVAMC staff before work can begin. Shop drawings will need to be coordinated with the A/E staff of the medical center and the A/E of the corresponding project. 4)As-Builds will be required at contract completion and before final payment can be made. 5)Must submit FDA 510K
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BreVAMC/VAMCCO80220/VA-250-10-RQ-0162/listing.html)
- Place of Performance
- Address: Louis Stokes Va Medical Center;10000 Brecksville Road;Brecksville, Ohio
- Zip Code: 44141
- Zip Code: 44141
- Record
- SN02135830-W 20100501/100429234823-0bfb31eb55462f837ddc837dfad35f47 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |