Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 07, 2010 FBO #3056
SOLICITATION NOTICE

70 -- Back-up Maintenance Service - Solicitation

Notice Date
4/5/2010
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
541519 — Other Computer Related Services
 
Contracting Office
Library of Congress, Contracts Services, Contracts Services, 101 Independence Ave SE, Washington, DC, 20540-9411
 
ZIP Code
20540-9411
 
Solicitation Number
QS-LCITS10Q0126
 
Point of Contact
Dianne Lovett, Phone: 202-707-3175
 
E-Mail Address
dlov@loc.gov
(dlov@loc.gov)
 
Small Business Set-Aside
N/A
 
Description
Soliciation QS-LCITS10Q0126 Maintenance on the telecom power systems at Madison, Adams, Jefferson, Landover and Taylor for 2010 - 2011 (POP 6/4/2010 to 6/3/2011) List of equipment needing maintenance Landover 1Power One Xscend DC Power System 1300ah Batteries and rack 13kva Inverter Adams & Jefferson 2Power One Xscend DC Power System 2200ah Batteries and rack Taylor Street 1Power One Xscend DC Power System 13kva Inverter Madison 1Power One Integrity DC power system 4750ah Batteries and racks 17kva scalable to 10.5 kva inverter Semi-Annual Battery Maintenance Procedures Procedures---twice per year: •Check individual batteries (12 volt blocks) float voltages •Check battery temperature for each battery rack •Record Battery Room Temperature •Inspect battery jars and racks •Check battery connections and torque where required •Perform a one-hour discharge capacity test using the system load (Note: manufacturer recommends discharge test if required). •Record available battery backup times •Alert customer if available battery backup times are less than 8 hours Semi-Annual Power Plant Maintenance Procedures Procedures---twice per year: •Check and record rectifier float voltage settings and adjust where required •Check and record plant load current •Check and record battery float current •Verify adequate recharge capability (minimum 1.45) •Verify adequate load coverage •Check rectifier current limiting capabilities during battery test •Check Major and Minor Alarm at originating and terminating ends •Check Voltage Threshold levels and adjust as required: 1.Low Voltage Alarm 2.High Voltage Alarm 3.Low Voltage Disconnect Voltage Level 4.Low Voltage Reconnect Voltage Level •Inspect load connections for tightness
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/LOC/CS/CS/QS-LCITS10Q0126/listing.html)
 
Place of Performance
Address: Library of Congress, 101 Independence Avenue, S. E., Washington, DC 20540-9410, Washington, District of Columbia, 20540, United States
Zip Code: 20540
 
Record
SN02112877-W 20100407/100405234936-9dd757e610b52f82db70e33fe2122607 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers