SOLICITATION NOTICE
Y -- Project 528A9-09-852, Replace 1000 T Absorber
- Notice Date
- 3/9/2010
- Notice Type
- Presolicitation
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of Veterans Affairs;Samuel S. Stratton VA Medical Center;113 Holland Avenue;Albany NY 12208-3410
- ZIP Code
- 12208-3410
- Solicitation Number
- VA-528-10-IB-0097
- Archive Date
- 5/8/2010
- Point of Contact
- Rachael RoneyContract Specialist
- E-Mail Address
-
Contract Specialist
(Rachael.Roney@va.gov)
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- Replace 1000 Ton AbsorberStratton VA Medical Center The Samuel S. Stratton VA Medical Center (hereafter "The VA" or "VA"), located at 113 Holland Ave., Albany NY 12208, intends to release a competitive Invitation for Bid (IFB) numbered VA-528-10-IB-0097, for a project entitled "Replace 1000 Ton Absorber" on or about the week of March 29, 2010. Unless additional notice is given or this notice is modified, the full IFB will be posted to the Government-wide Point of Entry (www.fbo.gov). The current intention of the VA is to procure these services competitively via a 100% Service-Disabled Veteran Owned Small Business (SDVOSB) set-aside. The applicable NAICS code will be 238220, with an applicable small business size standard of $14 Million. The estimated construction value of this project falls within the range of $500,000 and $1,000,000. Bid, performance and payment bonding will be required to respond to this IFB once released. This is a pre-solicitation notice synopsizing an upcoming competitive solicitation to satisfy the requirements of FAR 5.201 and 5.203. The work to be performed Replacing the 1000 Ton Absorber, Chiller Plant Building 54 and includes, but not limited to, the following: 1.Removing condenser pumps, chemical treatment system, steam piping, chilled water piping, condenser piping steam regulator, VFD'S, cooling tower fan motors, chilled water motors, concrete housekeeping pad and other items described in drawings and specifications. 2.Perform selective mechanical work to install a 1,000 ton chiller, two condenser pumps, two pump motor starters, 2 VFD controllers, two cooling tower motors, refurbish the cooling tower, replace PVC fill for each cell of cooling tower. Also install concrete housekeeping pad, chemical treatment system, DDC controls, chilled water piping, condenser water piping, pipe fitting, pipe hangers, wiring, electric controls, water balancing, BTU meter, flow meter and label all piping. 3.Tie-in new components with the existing finishes, mechanical/HVAC systems, electrical system, and plumbing. The Contracting Officer will not be able to answer any questions to this notice until a Invitation for Bids is issued and only by Request for Information (RFI's)
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/AlVAMC500/AlVAMC500/VA-528-10-IB-0097/listing.html)
- Record
- SN02087554-W 20100311/100309235435-aa0dcd0eca75b611b5b40d471615e659 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |