SOLICITATION NOTICE
Z -- Pittsburgh PA NDC Electrical Loadcenter - Qualification Statement
- Notice Date
- 3/9/2010
- Notice Type
- Presolicitation
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- United States Postal Service, Facilities Purchasing, Eastern Facilities Service Office, PO Box 27497, Greensboro, North Carolina, 27498-1103
- ZIP Code
- 27498-1103
- Solicitation Number
- 362575-10-A-Q002
- Point of Contact
- Cindy G Shepherd, Phone: 336/605-3536
- E-Mail Address
-
cindy.g.shepherd@usps.gov
(cindy.g.shepherd@usps.gov)
- Small Business Set-Aside
- N/A
- Description
- Contractor Qualification Statement - Solicitation Number 362575-10-A-Q002 The Postal Service is seeking Qualification Statements from construction companies wishing to be pre-qualified for award of a Fixed Price Contract for construction at the USPS Pittsburgh NDC. The facility is located at 300 Brush Creek Rd, Warrendale PA. Primary factors to be considered are background, past performance, experience, financial stability, capacity to perform, and safety. Qualification Statements will be evaluated by qualified personnel selected by a USPS contracting officer. All firms will be notified within 30 days of receipt of their Qualification Statement as to pre-qualification status. Contractors selected as being the most qualified will be placed on the pre-qualification list for this project. A Request for Proposal will be issued to pre-qualified firms at a later date. DESCRIPTION OF WORK: The work includes: 1. Replace four (4) obsolete double-ended unit substations (A, B, C & D) with new unit substations. 2. Each double ended unit substation shall consist of medium voltage interrupter switches, close-coupled transformers, and low voltage draw-out type secondary switchgear sections. 3. Three (3) of the four (4) replacement substations (B, C & D) shall be located in the same position as the existing. Due to minor dimensional issues with the new substations the existing housekeeping pads will be required to have extensions along the two sides and along the entire front. 4. One (1) replacement substation (A) cannot be relocated in its exact location due to NEC working space requirements. This new substation (A) shall be relocated to a new extension of the existing penthouse. This substation (A) shall be installed on a steel floor. 5. A temporary panelboard shall be required and is described in detail on the contract drawings. Extra rating plugs, size as specified, shall be provide as to make the temporary panelboard capable of being used to handle all of the temporary feeds required through the duration of the replacement process. The temporary panelboard shall be installed at a permanent location in the facility at the completion of the substation replacement. 6. Provide a complete addition to the existing penthouse structure as indicated on the contract drawings. This includes, but not limited to, supplying prefabricated penthouse wall and roof panels to match existing, roofing, structural support, and reinforcement steel. 7. Provide all scaffolding, man-lifts, and/or any other approved means of accessing the area below the existing loadcenters/substations so not to interfere with the facility’s normal operation. All means of access shall be OSHA approved and certified as safe for USPS employees to work under. Drawings and specifications defining the Scope of Work will be provided by USPS to selected prequalified contractors during construction solicitation phase. Total period of the project will be 550 calendar days. Estimated cost range is between $1,000,000 and $2,000,000. MINIMUM REQUIREMENTS: To be considered for prequalification: the company must be financially capable; possess and provide copy of applicable license(s) at the city/county level as required by the state of Pennsylvania for this type of work; home office located within a 100 mile radius of the construction site; have (5) consecutive years experience as an electrical construction company; and have completed or ongoing two (2) comparable projects within the past five (5) years. Comparable projects are defined as electrical system load center/switchgear replacement at or exceeding $1,500,000. QUALIFICATION STATEMENTS: Interested firms that meet the requirements may complete the attached Qualification Statement or contact Cindy Shepherd at cindy.g.shepherd@usps.gov to obtain the Qualification Statement. Please reference the solicitation number. Qualification statements will not be returned.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USPS/FP/MAFSO/362575-10-A-Q002/listing.html)
- Place of Performance
- Address: Pittsburgh PA Network Distribution Center, 300 Brush Creek Road, Warrendale, Pennsylvania, 15095-1002, United States
- Zip Code: 15095-1002
- Zip Code: 15095-1002
- Record
- SN02087172-W 20100311/100309235116-733147bc4becf09c14b6851c693f532d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |