SOURCES SOUGHT
68 -- MEDICAL GRADE LIQUID BULK OXYGEN (VISN 7)
- Notice Date
- 2/25/2010
- Notice Type
- Sources Sought
- NAICS
- 325120
— Industrial Gas Manufacturing
- Contracting Office
- Department of Veterans Affairs;Central Alabama Health Care System;West Campus;215 Perry Hill Road;Montgomery AL 36109-3798
- ZIP Code
- 36109-3798
- Solicitation Number
- VA-247-10-RI-0086
- Response Due
- 3/4/2010
- Archive Date
- 3/19/2010
- Point of Contact
- James A RoseContract Specialist
- E-Mail Address
-
Contract Specialist
(James.Rose3@va.gov)
- Small Business Set-Aside
- N/A
- Description
- DESCRIPTION: This is a sources sought to determine the availability of potential sources having the skills and capabilities necessary to perform/provide the SPECIFIED REQUIREMENT. All interested vendors are invited to provide information to contribute to this market survey/sources sought including, commercial market information. THIS IS NOT A SOLICITATION ANNOUNCEMENT. This is a sources sought synopsis only. Questions should be submitted by email to James.Rose3@va.gov. Provide only the requested information below. The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classification (Service Disabled/Veteran Owned Small Business (SDVOSB/VOSB), Hub-zone, 8(a), small, small disadvantage, woman-owned small business, or large business) relative to NAICS 325120, Industrial Gas Manufacturing (size standard 1000 employees). Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought synopsis, a solicitation announcement may be published on the FBO website. Responses to this sources sought synopsis are not considered adequate responses to the solicitation announcement. All interested offerors will have to respond to the solicitation announcement in addition to responding to this sources sought announcement. SPECIFIED REQUIREMENT: VA Southeast Network (VISN) 7 is seeking sources for a potential contract to provide distribution and supply of medical-grade liquid bulk oxygen for a base period with four (4) one-year option periods which may be exercised by the Government. All medical gas manufacturers and fillers of medical-grade liquid bulk oxygen must be registered with FDA as drug manufacturers. All oxygen shall be manufactured, processed, packed, transported, and stored according to FDAs Current Good Manufacturing Practices (CGMP) regulations, and all labeling shall comply with FDAs labeling regulation (21 CFR Part 201). Liquid bulk oxygen delivered shall be medical-grade and shall meet or exceed the standards cited in the current edition of the United States Pharmacopoeia/National Formulary (U.S.P.). Contractor-owned equipment shall be installed, inspected, and maintained by the contractor without additional cost to the Government. Through the duration of the contract, the contractor shall be liable for the integrity, suitability, and safety of contractor-owned tank(s) that will insure compliance with applicable regulations, standards and normal good practices. Manifold, cylinders for the reserve supply, liquid converter, alarm switch, regulator, valves, level indicator, and any other devices or connections required for proper tie-ins with the facility's gas system shall be furnished by the contractor, without cost to the Government. The manifold or liquid converter shall deliver gas at a pressure and rate of flow adequate to supply the system. Each liquid oxygen storage container shall have an outlet that allows access for testing the purity of the oxygen. Prior to first filling, contractor must perform in-service training to include the following facets for contractor-owned systems: the refill procedure, any preventive maintenance support requirements that may be needed from the medical center systems, and an explanation of all the volume alarm and low pressure set-points. The contractor will provide written procedures and training for VA staff for protocols to accomplish emergency shutdowns or other sudden, unplanned termination of the refilling process. Prior to first filling, and annually thereafter, alarm set-point testing and written verification must be presented through the use of a qualified third party expert per NFPA 99, 2002 Edition for contractor-owned systems. Any code deficiencies in the Medical Center's existing system, as defined by NFPA 50, 1.3.3, "Bulk Oxygen System", must be identified by the contractor. A detailed explanation of these deficiencies must be presented in writing to the Contracting Officer Technical Representative (COTR). Receipt of this written explanation must be signed for by the COTR. Prior to first filling, and annually thereafter, the contractor must verify, in writing, the accuracy of all gauges on contractor-owned tanks. VISN 7 facility shall provide a suitable location and foundation for the installation of the contractor-owned bulk oxygen tank(s). Additionally, VAMCs facility shall provide access to an electrical power source and hook-up to a facility-maintained alarm system. Contractor will provide 24/7 emergency contact name(s) and telephone number(s). Responses must be emailed to James.Rose3@va.gov no later than 4:00pm CST, March 04, 2010. Your response should include both the STATEMENT OF CABABILITY and BUSINESS SIZE AND SOCIO-ECONOMIC STATUS information as explained below. Please place "Attention: Medical-grade liquid bulk oxygen" in the subject line of your email. This notice is to assist the VA in determining sources only. A SOLICITATION IS NOT CURRENTLY AVAILABLE. If a solicitation is issued it will be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this announcement. REQUESTED INFORMATION: (1) STATEMENT OF CABABILITY: Submit a brief description [three (3) pages or less] that shows your company can provide distribution and supply of medical-grade liquid bulk oxygen. Include past experience in performing these services for the VA, other Government (Federal or State) agency, or for a private medical facility. Please specify your availability to start date. Please indicate your address (2) BUSINESS SIZE AND SOCIO-ECONOMIC STATUS: (a) Indicate whether your business is large or small (b) If small, indicate if your firm qualifies as a small, emerging business, or small disadvantaged business (c) If disadvantaged, specify under which disadvantaged group and if your firm is certified under Section 8(a) of the Small Business Act (d) Indicate if your firm is a certified Hub-zone firm (e) Indicate if your firm is a woman-owned or operated business (f) Indicate if your firm is a certified Service-Disabled Veteran Owned Small Business (SDVOSB) or Veteran Owned Small Business (VOSB) (g) Include the DUNS number of your firm. (h) State whether your firm is registered with the Central Contractor Registration (CCR) at http://www.ccr.gov and/or the VetBiz Registry at http://vip.vetbiz.gov/. If not, please NOTE: any future solicitation could only be awarded to a contractor who is registered in CCR and to receive award based on VOSB or SDVOSB status you must be registered in the VetBiz Registry. Contracting Office Address: Department of Veterans Affairs: Central Alabama Veterans Healthcare Systems (90C) 215 Perry Hill, Bldg. 6, Room 207, Montgomery, AL 36109 Place of Performance: Tuscaloosa VAMC, 3701 Loop Road East, Tuscaloosa, Alabama 35404. Birmingham VAMC, 700 South 19th Street, Birmingham, Alabama 35233. CAVHCS VAMC, 215 Perry Hill, Montgomery, Alabama, 36109. CAVHCS VAMC, 2400 Hospital Road, Tuskegee, Alabama 36083. Columbia VAMC, 6439 Garners Ferry Road, Columbia, South Carolina 29209. Atlanta VAMC, 1670 Clairmont Road, Decatur, Georgia 30033. Augusta VAMC, 800 Bailie Drive, Augusta, Georgia 30901. Augusta VAMC, 1 Freedom Way, Augusta, Georgia 30904. Dublin VAMC, 1826 Veterans Blvd., Dublin, Georgia 31020 Point of Contact(s): James A. Rose, Contract Specialist 478-274-5866 Fax
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/MoVAMC/VACAHCS/VA-247-10-RI-0086/listing.html)
- Place of Performance
- Address: VISN 7 VA MEDICAL FACILITIES;215 PERRY HILL ROAD;MONTGOMERY, AL
- Zip Code: 36109
- Zip Code: 36109
- Record
- SN02076145-W 20100227/100226094151-aa04b4461c083fd6458a80178d78df26 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |