SOURCES SOUGHT
Z -- Elevator Replacement/Repair - USPO Courthouse / Galveston, TX
- Notice Date
- 2/8/2010
- Notice Type
- Sources Sought
- NAICS
- 238290
— Other Building Equipment Contractors
- Contracting Office
- General Services Administration, Public Buildings Service (PBS), Acquisition Services (7PMO), 819 Taylor St. Room 12B01, Fort Worth, Texas, 76102
- ZIP Code
- 76102
- Solicitation Number
- RTX10016ELEV
- Point of Contact
- Sylvia Garza,
- E-Mail Address
-
sylvia.garza@gsa.gov
(sylvia.garza@gsa.gov)
- Small Business Set-Aside
- N/A
- Description
- Service/Prisoner Elevator No. 3 This elevator was in the basement when the basement was flooded, the water was over the top of the elevator cab. All of the cab, platform, hoist ropes, car doors, hoistway doors and entrance, door operators (2), safeties, wiring and fixtures must be replaced or repaired to like new condition. All of the hoistway wiring and all devices that are in the elevator hoistway below the first floor landing must be replaced. Basically, everything on the elevator except the controller and hoist machine will need replacement. All Marshal's security equipment, i.e. camera's keypad, etc., shall replaced by the USMS security contractors and is not a part of the elevator work. Also provide a pit flood monitoring device conforming to the following specification. PIT FLOOD ALARM: Provide a two-stage pit flood device. Stage I shall operate when the water level exceeds two inches above the pit floor, and shall activate a bell mounted in the pit. 1. Stage II shall operate when the water level exceeds six inches above the pit floor, and shall activate a circuit which shall initiate Emergency Fire Service Recall Phase I to recall to the second (alternate fire) landing, and remove the elevators from operation until the pit flood device has been reset. 2. The lowest level car call shall be blocked on Emergency Fire Service Phase II only on pit flood alarm operation to prevent operation into a flooded pit. Sallyport Elevator No. 4 This elevator was also in the basement when flooded, but the hydraulic elevator machine room is also located in the basement. This elevator and ALL of the associated equipment was destroyed by floodwater. The cab, platform, hoistway doors, car doors, door operator, jack, pump unit and all piping, wiring and fixtures must be replaced or repaired to like new condition. The only part of the elevator that can remain is the guide rails. A complete new elevator will be required. All Marshal's security equipment, i.e. camera's keypad, etc., shall replaced by the USMS security contractors and is not a part of the elevator work. Also provide a pit flood monitoring device conforming to the following specification. PIT FLOOD ALARM: Provide a two-stage pit flood device. Stage I shall operate when the water level exceeds two inches above the pit floor, and shall activate a bell mounted in the pit. 1. Stage II shall operate when the water level exceeds six inches above the pit floor, and shall activate a circuit which shall initiate Emergency Fire Service Recall Phase I to recall to the second (alternate fire) landing, and remove the elevators from operation until the pit flood device has been reset. 2. The lowest level car call shall be blocked on Emergency Fire Service Phase II only on pit flood alarm operation to prevent operation into a flooded pit.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/7PMO/RTX10016ELEV/listing.html)
- Place of Performance
- Address: U.S. Post Office Courthosue, 601 Rosenbert St., Galveston, Texas, 77550, United States
- Zip Code: 77550
- Zip Code: 77550
- Record
- SN02060841-W 20100210/100208234938-0d852f8a67727a0856d71245dfd3053c (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |