Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JANUARY 16, 2010 FBO #2975
SOURCES SOUGHT

65 -- Hospital Beds - Sources Sought Amendment 0001 ***Contact freddie.beaulieux@va.gov for Specifications and Entrapment specifics ***

Notice Date
1/14/2010
 
Notice Type
Sources Sought
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
National Acquisistion Center;National Contract Service;PO Box 76, Building 37;Hines, IL 60141
 
ZIP Code
60141
 
Solicitation Number
VA-797-09-RI-0043
 
Response Due
1/15/2010
 
Archive Date
1/21/2010
 
Point of Contact
freddie.beaulieux@va.gov
 
Small Business Set-Aside
N/A
 
Description
SpecificationsHospital Beds January 2010 All offered beds must meet the following minimum specifications in order to be evaluated and considered for award: 1.Minimum Weight Capacity -- 400 pounds 2.Power -Electric head and foot sections both elevate independently and height of bed raises and lowers independently by electric controls. Will be tested with rails in locked and upright position. Must be capable of this function regardless of which type of rail is on the bed (i.e. full, half, or split rails.) 3.Head/Foot Boards - Interchangeable 4.Rails - Beds must be able to accept full, half and split rails. 5.Minimum clearance height between floor and bed frame -5 inches 6.Maximum bed height from the floor to the top of the bed's side frame without mattress -15 inches 7.Width of frame - minimum 35 inches. 8.Maximum overall length measured from the outside of the headboard and footboard - 90 inches 9.Motors- for head control, foot control, and elevation control - all motors must be interchangeable. 10.The motors must be double insulated. 11.The power cord plug must be suitable for a two-slot ungrounded outlet. 12.All motors that control the functions of the bed must have hand crank capability 13.Trapeze Mount - must accept bed mounted trapeze 14.Crank provided. 15.One person set-up and transport. This must be demonstrated by a representative of the offeror and accomplished within one hour. 16.Must meet "2006 FDA Hospital Bed System Dimensional and Assessment Guidance to Reduce Entrapment". (The bed will be tested with the pressure reduction mattress and rails provided by the offeror.) CONTACT freddie.beaulieux@va.gov FOR ENTRAPMENT GUIDELINES 17.Must meet ANSI/AAMI ES60601-1:2005, Medical electrical equipment-Part 1: General requirements for basic safety and essential performance 18.Wheels/Casters - Four total - Either two wheels with two locking casters or four wheels with locking casters. 19.Hand control for all electric functions 20.Must have no pinching or sharp outside edges or other physical hazards to patient safety. The following accessory items must be available to be ordered with bed or at a later time: "Full, half and split rails "Trapeze "Mattress - Foam Pressure Reduction with a minimum sleep surface of 36 by 80 inches. Mattress must be in compliance with all federal and state fire codes and regulations. Literature must be submitted and marked clearly.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANAC/VANAC/VA-797-09-RI-0043/listing.html)
 
Record
SN02042498-W 20100116/100114234537-2972b99085a331e0c4113e99d107ac5f (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.