SOLICITATION NOTICE
J -- USCGC BLOCK ISLAND (WPB-1344) 10 DRYDOCK REPAIRS
- Notice Date
- 12/18/2009
- Notice Type
- Presolicitation
- NAICS
- 336611
— Ship Building and Repairing
- Contracting Office
- Department of Homeland Security, United States Coast Guard (USCG), Commanding Officer (vpl), USCG Maintenance and Logistics Command - Atlantic, 300 East Main Street, Suite 600, Norfolk, Virginia, 23510-9102
- ZIP Code
- 23510-9102
- Solicitation Number
- HSCG80-10-Q-P45D25
- Archive Date
- 5/28/2010
- Point of Contact
- Louis J Romano, Phone: (757)628-4651, Tomeka Evans, Phone: 757-628-4666
- E-Mail Address
-
louis.j.romano@uscg.mil, tomeka.evans@uscg.mil
(louis.j.romano@uscg.mil, tomeka.evans@uscg.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- The U.S. Coast Guard is setting aside this acquisition for Small Business concerns. The Coast Guard intends to conduct this procurement in accordance with Federal Acquisition Regulation (FAR) Part 12, Acquisition of Commercial Items and FAR Subpart 13.5, Test Program for Certain Commercial Items. The NAICS Code is 336611 and the SIC is 3731. The acquisition is for drydock repairs to the USCGC BLOCK ISLAND (WPB-1344), a 110 FOOT "C" CLASS PATROL BOAT, at the contractor's facility. The simplified acquisition will be issued as a Best Value Request for Quotes (RFQ), on or about 13 January 2010 with quotes due on or about 02 February 2010 via the Federal Business Opportunities (FEDBIZOPPS) web page at https://fbo.gov. This requirement will be evaluated using past performance as an evaluation factor. It is incumbent upon contractors to monitor the FEDBIZOPS web page for the RFQ release and all subsequent amendments. FEDBIZOPS also contains an option for automatic notification service. Hard copies of the specification and solicitation will not be issued. A CD-ROM containing all applicable drawings is available free of charge to contractors upon request not later than three (3) days from the solicitation issuance. The CD-ROM(s) contain WINDOWS compliant raster/vector formats (e.g.*.DWF, etc). The home pier of the vessel is 2301 East Fort Macon Road, Atlantic Beach, NC 28512. The vessel's availability is for Forty-two (42) calendar days, starting on or about 12 April 2010. This requirement is geographically restricted to a facility within 500 nautical miles, one-way or 1,000 nautical miles, round-trip of the vessels homeport of Atlantic Beach, North Carolina. The scope of this acquisition is for the dry docking, overhauling, cleaning and repairing of various items aboard the USCGC BLOCK ISLAND (WPB-1344). Provide all labor, material and equipment necessary to perform dry dock repairs, including but not limited to the following: routine drydocking, provide temporary logistics, clean and inspect fuel service tanks, clean and inspect fuel stowage and overflow tanks, clean and insect oil and oily waste tanks, clean and insect sewage collection and holding tank, clean and inspect grey water collection and holding tanks, clean sewage piping system, clean grey water piping system, clean and disinfect potable water tanks, preserve sewage collection and holding tanks - 100%, preserve sewage collection and holding tank - partial, preserve grey water collection and holding tank - partial, preserve oil and oily water tanks - 100%, preserve oil and oily water tanks - partial, remove, inspect and reinstall propellers, repair propeller root erosion, remove, inspect and reinstall propeller shafts, overhaul mechanical shaft seal assemblies, renew water-lubricated propeller shaft bearings, renew sea valves and pumps, overhaul duplex sea strainers, overhaul stabilizing fins, overhaul steering gear components, remove, inspect and reinstall rudder assemblies, inspect and maintain cathodic protection system, renew capastic fairing, renew Dopler speed log and overhaul Doppler valve, renew depth indicating transducer, preserve underwater body - 100%, preserve underwater body - partial, inspect mde exhaust system, preserve forward peak compartment, preserve forward void, preserve forward auxiliary machinery space, install new gray water pumps and piping, improve ship's ventilation, perform aluminum hull and structural repairs - ¼" plate, perform aluminum hull and structural repairs - 5/16" plate, perform hull and structural plating repairs - crack (aluminum), perform hull and structural plating repairs -eroded weld (aluminum), perform hull and structural plating repairs - overlay welding (aluminum), perform steel hull and structural plating repairs (5-pound), perform hull and structural plating repairs (6.0-pound or 5.63 pound), perform steel hull and structural plating repairs (7.5-pound or 7.65-pound), perform hull and structural plating repairs - corrugated plate (4.0 pound), perform steel structural member repairs - 1" x 3" Steel T-bar framing, perform hull and structural plating repairs - crack (steel), perform hull and structural plating repairs - eroded welds (steel), perform hull and structural plating repairs - overlay welding (steel), install hot water on-demand unit, install new life rafts, install new searchlight, replace reverse osmosis watermakers, modify oily water separator piping, ultrasonic thickness measurements, preserve weather decks, renew structural closures, renew pilothouse windows, renew various interior deck drains, renew latex terrazzo deck covering systems, install new deck covering systems, fabricate and install new canopy, renew fuel transfer piping, composite labor rate, GFP report and lay days. All welding and brazing shall be accomplished by trained welders who have been certified by the applicable regulatory code performance qualifications procedures. For further information or questions regarding this solicitation or a copy of the CD -ROM, please contact Mr. Louis Romano at (757) 628-4651, or by e-mail to Louis.J.Romano@uscg.mil.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DHS/USCG/COUSCGMLCA/HSCG80-10-Q-P45D25/listing.html)
- Place of Performance
- Address: This requirement is geograhically restricted to a facility within 500 nautical miles, one-way or 1,000 nautical miles, round-trip of the vessels homeport of Atlantic Beach, North Carolina., United States
- Record
- SN02028001-W 20091220/091218235759-453b6bce7f59f2bac72f2a52806c5a8d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |