Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF NOVEMBER 27, 2009 FBO #2925
SOLICITATION NOTICE

J -- Gen & transfer switch maintenance

Notice Date
11/25/2009
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
VA Northern California HealthCare System;5342 Dudley Blvd. Bldg 98;McClellan Business Park CA 95652
 
ZIP Code
95652
 
Solicitation Number
VA-261-10-RQ-0055
 
Response Due
11/30/2009
 
Archive Date
12/30/2009
 
Point of Contact
maria.teodoro@va.gov
 
E-Mail Address
Contract Specialist
(maria.teodoro@va.gov)
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis-solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested and a written solicitation will not be issued.The Solicitation number is VA-261-10-RQ-0055 with a due date of November 30, 2009 by 4pm. The solicitation is a Request for Quote (RFQ) for generator and transfer switch at VA Medical Central in Reno, Nevada. This solicitation is a Set-Aside for Small Businesses only. The NAICS code is 811310, size standard of $7.0 million. Product Service code of J099 applies. All questions must be submitted through email to maria.teodoro@va.gov. Any amendment issued against this RFQ will be available from www.fedbizopps.gov. Contractor is responsible for submitting all documents required in accordance with the RFQ, including any amendments which will be posted on this website. This action is also subject to availability of funding. Quotations shall be valid for 60 days from offer due date. The following provisions and clauses apply plus any addenda: FAR 52.212-1 Instructions to Offerors - Commercial Items (JUN 2008) FAR 52.212-2; Evaluation - Commercial Items (JAN 1999) For the purposes of this clause the evaluation factors will be price, technical and past performance. Evaluation factors are listed in descending order of importance. Technical and past performance, when combined, are approximately equal to price. FAR 52.212-3 Offeror Representations and Certifications - Commercial Items (AUG 2009) FAR 52.212-4 Contract Terms and Conditions - Commercial Items (MAR 2009) FAR 52.212-5 Contract Terms and Conditions to Implement Statutes or Executive Orders - Commercial Items (AUG 2009) FAR 52.217-8 Option to Extend Services (NOV 1999) FAR 52.233-2 Service of Protest (SEP 2006) FAR 52.232-18 Availability of Funds (APR 1984) FAR 52.247-34 F.O.B. Destination (NOV 1991) VAAR 852.203-70 Commercial Advertising (JAN 2008) VAAR 852.216.70 Estimated Quantities (APR 1984) VAAR 852.233-70 Protest Content (JAN 2008) VAAR 852.233-71 Alternative Protest Procedure (JAN 1998) VAAR 852.237-70 Contactor Responsibilities (APR 1984). VAAR 852.270-1 Representatives of Contracting Officers (JAN 2008) VAAR 852.273-70 Late Offers (JAN 2003) VAAR 852.273-74 Award Without Exchanges (JAN 2003) VAAR 852.273-75 Security Requirements for Unclassified Information Technology Resources (OCT 2008) VAAR 852.273-76 Electronic Invoice Submission (OCT 2008) This RFQ and incorporated provisions and clauses are those in effect through FAC 2005-36. Offeror shall submit all information with offer as required in 52.212-1; a completed copy of provisions 52.212-3 Offeror Representations and Certifications and the Contract Terms and Conditions - Commercial items applies to this acquisition. Offeror may obtain copies of the referenced provisions and clauses at http://arnet.gov/far and http://www.va.gov/oa&mm/vaar/ or by sending an email to the Contracting Officer at maria.teodoro@va.gov. The Contracting Officer may add any additional contract requirements or terms and conditions (such as contract financing arrangements or warranty requirements) determined by the Contracting Officer to be necessary for this acquisition and consistent with customary commercial practices. Quotations can be electronically send to maria.teodoro@va.gov Web based offers will not be accepted. Price/Delivery Schedule DESCRIPTION OF QTY U/P Total SUPPLIES/SERVICES CONTRACTOR TO PROVIDE ALL NECESSARY SUPERVISION, LABOR, TOOLS, TRAVEL, EQUIPMENT AND MATERIALS TO ACCOMPLISH EMERGENCY GENERATOR AND TRANSFER SWITCH MAINTENANCE ON SEVEN (7) GENERATORS AT THE VA MEDICAL CENTER IN RENO, NV. SERVICE TO INCLUDE ANNUAL AND QUARTERLY INSPECTIONS, A 4 HOUR LOAD TEST AND RENTAL UNIT AS REQUIRED. 1 JB STATEMENT OF WORK Contractor to provide all necessary supervision,labor, tools, travel, equipment, and materials to accomplish emergency generator and transfer switch maintenance on seven(7) generators at the VA Medical Center in Reno, Nevada. Service to include Annual and Quarterly Inspections, a 4 hour load test and rental unit as required. GENERATOR ANNUAL P.M. SERVICE (to include): Before Starting Engine: "Check engine oil level and coolant level. "Check block heater to maintain coolant temp. (Approximately 90 Deg. F in the block) "Check fuel level in storage tank advise when main fuel tank is below full. "Check fuel day tank pump manually for proper operation if applicable. "Check battery water level and top as necessary. "Check battery voltage. (13 - 14 VDC or 26 - 27 VDC) "Check battery terminals for corrosion and connections for tightness (clean if necessary) "Check visually engine/generator electrical wiring harnesses and terminal connections "Check engine/generator control panel gauges and alarm lights. "Check equipment mounting (vibration isolators) and accessory mounts. "Check radiator for plugging, level switch if applicable, and leaks. "Check engine governor controls (linkage) if applicable. "Check air induction system including turbocharger Engine Running: "Check oil pressure, fuel pressure, belt driven accessory drives. "Check oil level and add oil as required. "Check generator frequency (including stability), voltage, temperatures and pressures "Check for leaks or unusual noises. "Check engine exhaust system "Check engine cooling fan After Stopping Engine: "Check/verify all switches are in proper positions for automatic start. "Check fuel level in tank. "Record battery charger volts, check for proper operation. "Remove, clean and reinstall all battery connections if necessary. "Inspect generator for cleanliness. "Drain crankcase oil and replace with new oil. Take oil samples for analysis. "Remove and replace oil and fuel filters. "Inspect air filter(s) "When load test portion of maintenance proposal is accepted the following applies. oStart engine and operate using resistive load bank for a period of two hours. oCheck generator output-voltage, frequency, amperage, temperatures and pressures every 15 minutes (record onto chart) Reporting: "Provide service report for each visit and advise customer of potential problems which will require further attention. Emergency Servicing: "Provide emergency phone numbers of all technicians "Provide 24-hour emergency repair coverage. INSPECTION SERVICE-Monthly, Quarterly or Semi-Annual (to include): General Inspection "Visually check complete engine/generator set "Check equipment mounting (vibration isolators) and accessory mounts. Engine Controls and Control Panel "Check engine/generator control panel gages and alarm lights. "Check instruments for normal operation "Verify controls are set in automatic mode if applicable. Engine Lubrication System "Check oil level and add oil as required. "Check oil pressure using equipment mounted gauge Engine Cooling System "Check engine coolant level, concentration of coolant conditioner (inhibitor) "Check engine cooling fan and radiator condition "Check condition of belts, hoses, and plumbing connections "Check jacket water heater temperature Engine Fuel System "Check fuel levels in day tank and main tank "Check fuel pressure using equipment mounted gauge "Check fuel piping for leaks Engine Air Induction System "Check air intake system piping, air cleaner and air restriction gauge "Check engine exhaust system including after treatment devices Engine Governor "Check linkage and ball joints (if applicable) "Check air/fuel ratio control (if applicable) "Check for leaks, oil level (if applicable) Engine Electrical Starting System "Check visually batteries and connections, water level and correct if necessary "Check battery cap vents (if applicable) "Check battery charging system for proper operation Generator and Generator Switchgear "Check generator frequency, voltage, amperage using building load (if applicable) "Check air screen, leaks or unusual noises. "Inspect generator for cleanliness. "Operate generator circuit breaker (if applicable)
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANCHCS/VANCHCS/VA-261-10-RQ-0055/listing.html)
 
Record
SN02011497-W 20091127/091125234806-0fdd6f363ef6f439f7a40bc568809599 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.