MODIFICATION
K -- Engine Test Cell Upgrade & Sustainment, Building 100, USCG Aviation Logistics Center, Elizabeth City, NC - Photos of T700 Coupling Shaft
- Notice Date
- 11/18/2009
- Notice Type
- Modification/Amendment
- NAICS
- 488190
— Other Support Activities for Air Transportation
- Contracting Office
- Department of Homeland Security, United States Coast Guard (USCG), Commanding Officer, USCG Aviation Logistics Center, HU25, HH65, H60J, C130, ESD, IOD, ISD, CASA or ALD, Elizabeth City, North Carolina, 27909-5001, United States
- ZIP Code
- 27909-5001
- Solicitation Number
- HSCG38-10-R-410009
- Point of Contact
- Ginger G Woodington,
- E-Mail Address
-
ginger.g.woodington@uscg.mil
(ginger.g.woodington@uscg.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- T700 Coupling Shaft T700 Coupling Shaft T700 Coupling Shaft T700 Coupling Shaft PLEASE NOTE: PLEASE READ THE SYNOPSIS/SOLICITATION, STATEMENT OF OBJECTIVES (SOO), AND OTHER ATTACHMENTS - MANY OF THE QUESTIONS BEING ASKED ARE ALREADY COVERED IN THESE DOCUMENTS. THE SOO APPROACH HAS BEEN USED TO ALLOW MAXIMUM FLEXIBILITY FOR EACH OFFEROR TO PROVIDE ITS OWN INNOVATIVE APPROACH/SOLUTION IN RESOLVING THE GOVERNMENT'S OBJECTIVES. Q80: Can you please post pictures of the T700 coupling shaft. A80: Yes. Four photos have been attached for review. Q81: What are the current maintenance schedules? A81: Weekly, monthly, semiannual and annual preventive maintenance schedules, and calibration every 6 months. Q82: The ATF3 test cell supports the HU-25 Falcon Jet which is currently being phased out with a twilight date of 2014. The SOO states that "all software must have the ability to be reprogrammed to accommodate a new engine type in the event the USCG re-engines the HU-25 Falcon." Which future engine is under consideration? A82: The future engine selection has not been determined. Q83: What is the capacity of the water reservoir? A83: The current water reservoirs for the cooling tower and pump house are a 2000 gallon hot water reservoir and a 4000 gallon cold water reservoir. See facilities drawing number 400185; C4, T18, and T24. Q84: Because of the volume of questions and that many have not yet been answered following the industry day event and because of the close time period between the Thanksgiving holiday and the proposal due date; we would like to respectfully request a two week extension on the proposal due date. A84: A two-week extension is not possible. As explained at the Industry Day, the Coast Guard has a very limited time frame in which to obligate the funds for this project. Questions were due by close of business on November 16, 2009, and are being responded to in a timely manner. All questions received by the due date will be answered by close of business on November 20, 2009. Q85: The FBO notice issued on 6 November indicates Sytronics has issued an appeal to the Office of Hearing and Appeals concerning the NAICS code assigned to the solicitation. Does this mean the Government is considering changing the NAICS Code? If so what is the alternative NAICS code the Government and/or Sytronics is requesting to be used? A85: The Coast Guard does not intend to change the NAICS Code. However, the Coast Guard stands ready to fully comply with the findings of the SBA OHA. A response is expected from the OHA by close of business on November 20, 2009. Q86: Since Sytronics has requested the Office of Hearing and Appeals to make a ruling on a new NAICS code for this solicitation, do potential offerors have a chance to provide comments to the OHA on the potential NAICS code change? A86: SBA OHA rules of practice and other information can be found at www.sba.gov/oha. Q87: Does the proposal Technical Volume 100 page limit include Factors II, III, and IV? A87: As per Para 6 of the Proposal Submittal Instructions, "proposals, excluding pricing and manufacturer data sheets, shall not exceed 100 pages."
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DHS/USCG/USCGARSC/HSCG38-10-R-410009/listing.html)
- Place of Performance
- Address: United States Coast Guard Base, 1664 Weeksville Road, Elizabeth City, North Carolina, 27909, United States
- Zip Code: 27909
- Zip Code: 27909
- Record
- SN02006212-W 20091120/091118235223-376c3c6f4e735e8e71a99486a56d4f01 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |