MODIFICATION
59 -- Circuit Boards
- Notice Date
- 11/12/2009
- Notice Type
- Modification/Amendment
- NAICS
- 334418
— Printed Circuit Assembly (Electronic Assembly) Manufacturing
- Contracting Office
- RDECOM Contracting Center, Aberdeen Installation Contracting (RDECOM-CC), Directorate of Contracting, 4118 Susquehanna Avenue, Aberdeen Proving Ground, MD 21005-3013
- ZIP Code
- 21005-3013
- Solicitation Number
- W91ZLK-10-T-0013
- Response Due
- 11/16/2009
- Archive Date
- 1/15/2010
- Point of Contact
- Susan Sowa, 410-278-0888
- E-Mail Address
-
RDECOM Contracting Center, Aberdeen Installation Contracting (RDECOM-CC)
(susan.sowa@us.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- Amendment W91ZLK-10-T-0013 0002 is issued to provide answers to additional questions. The closing date of the solicitation has been extended through November 16, 2009 @ 5:00 PM Eastern Standard Time. Please SUBMIT YOUR QUOTATIONS to Ms. Sowa at the RDECOM Contracting Center Aberdeen Installation Contracting Division, 4118 Susquehanna Avenue, Aberdeen Proving Ground, MD 21005-3013. Quotations may be submitted via email to: susan.sowa@us.army.mil or Fax 410-306-3726. Quotations must be signed, dated, and received by the closing date. For questions concerning this Request for Quotations contact Susan Sowa Contracting Specialist @ email susan.sowa@us.army.mil Additional questions must be received no later than November 10, 2009 @ 3:00 PM. Question 6: Is there an assembly print available for this PCB assembly that would list out any specific notes or requirements on the assembled board? Answer: 5-15-32419 is the BAWS Control Circuit Board Assembly and the PL5-15-32419 is the BOMs that goes with this drawing. Question 7: Regarding item number 15 on the BOM (P/N PR020000205109JR500). Is there a suitable replacement for this part? Answer: ITEM # 15 is available in digikey. PLEASE NOTE THAT ITEM #15 HAS THE PART NUMBER CORRECT BUT THE DESCRIPTION HAS AN ERROR. IT SHOULD BE 51 OHMS, NOT 51K OHMS. ANY 51 OHMS, 2W RESISTOR AND HAS EQUIVALENT SPECS AS PR020000205109JR500 THAT WOULD FIT THE FOOTPRINT WOULD WORK. Question 8: Is the wire length specified on the assembly spreadsheet located on the ASFI website (Additional documentation)in inches? The wire length is listed in the BOM (PL5-15-32419); for example, ITEM 18 requires 18 inches of wire. The same spreadsheet makes reference to many NOTES which are not available on the documentation presented at the ASFI website. Can you direct me to where I can find these NOTES? Answer: If you are talking about the notes reference in the parts list(PL5-15-32419) then the notes can be found in drawing 5-15-32419. Question 9: Is there a gerber file associated with these drawings? This will affect our bid, because it is more expensive to recreate the schematic for the PCB's without this file. Answer: The Gerber files were uploaded with Amendment W91ZLK-10-T-0013 0001. Question 10: The drawings and bill of materials refer to notes (ex. See note 1). Are these additional notes posted anywhere, and if not, will we be able to get them. Answer: The notes is listed in 5-15-32419, the BOM and 5-15-32419 goes together.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/5a51e171168c6344aaa8ce84ee54af6b)
- Place of Performance
- Address: RDECOM Contracting Center, Aberdeen Installation Contracting (RDECOM-CC) Directorate of Contracting, 4118 Susquehanna Avenue Aberdeen Proving Ground MD
- Zip Code: 21005-3013
- Zip Code: 21005-3013
- Record
- SN02002774-W 20091114/091112235413-5a51e171168c6344aaa8ce84ee54af6b (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |