SOLICITATION NOTICE
41 -- Remove and Replace 4 Glycol Condensing Units
- Notice Date
- 9/8/2009
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of the Air Force, Air Combat Command, 1st CONS, 74 Nealy Avenue, Suite 100, Langley AFB, Virginia, 23665
- ZIP Code
- 23665
- Solicitation Number
- FA4800-09-Q-BD08
- Archive Date
- 9/26/2009
- Point of Contact
- Beverly A. Turman-Dawson, Phone: 7577644918, Steve F Pillo, Phone: 757-764-2930
- E-Mail Address
-
Beverly.Dawson.ctr@langley.af.mil, steven.pillo@langley.af.mil
(Beverly.Dawson.ctr@langley.af.mil, steven.pillo@langley.af.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- PERFORMANCE WORK STATEMENT TO REPLACE EXISTING GLYCOL UNITS BLDG 25 Langley AFB, VA 23665 Scope of Work: The contractor shall provide non-personal services to furnish all labor, tools, equipment, transportation, materials, testing and supervision to remove and replace 4 existing Glycol Condensing units and all the associated components in Bldg 25. 1. Removal: Remove 4 existing outdoor condenser units and 4 existing glycol cooled indoor condensing units. Contractor shall recover all the glycol from the existing units and dispose of according to all Federal, State and local requirements. 1.1. The contractor shall provide all necessary equipment to remove units from the roof of B25. The contractor shall dispose of all removed material, parts and system components in accordance to all Federal, State and local requirements. 2. Replacement: The contractor shall provide all necessary equipment to: 2.1. Install 4 new Data Aire Model DAFC-4034 nominal 40 ton fluid condensers with factory mounted, wired and piped glycol pumps, pump enclosures and 10 gallon expansion tanks. 2.2. Install 4 Data Aire Model DAGD-1634 nominal 16 ton glycol cooled condensing units with downflow airflow, hot water reheat, 3-way water regulating valves, floorstands with turning vanes, vibration isolation pads and 4 inch 60% efficiency filters with 1 inch prefilters. Voltage is 460/60/3. 3. Inspection: The contractor shall test all equipment for but not limited to leaks, freeze protection and flow. The contractor shall provide system specifications and written test results to the government representative prior to inspection. All work will be inspected by 1 CES prior to acceptance. 4. Warranty: Standard warranty is for this type of work is one year parts and labor.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/ACC/1CONS/FA4800-09-Q-BD08/listing.html)
- Place of Performance
- Address: Bldg 25, Langley AFB, Virginia, 23665, United States
- Zip Code: 23665
- Record
- SN01945366-W 20090910/090909084459-26574d612f0c21c9af69da2d613a2a40 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |