Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 05, 2009 FBO #2842
MODIFICATION

70 -- RAID STORAGE SYSTEMS (Brand Name or Equal)

Notice Date
9/3/2009
 
Notice Type
Modification/Amendment
 
NAICS
423430 — Computer and Computer Peripheral Equipment and Software Merchant Wholesalers
 
Contracting Office
Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B129, Mail Stop 1640, Gaithersburg, Maryland, 20899-1640
 
ZIP Code
20899-1640
 
Solicitation Number
NB184000-9-06285
 
Archive Date
9/24/2009
 
Point of Contact
Richard Cordero, Phone: 3019753976, Joseph L. Widdup, Phone: (301) 975-6324
 
E-Mail Address
rcordero@nist.gov, joseph.widdup@nist.gov
(rcordero@nist.gov, joseph.widdup@nist.gov)
 
Small Business Set-Aside
N/A
 
Description
The purpose of tamendment one is to correct the description of item number one and to provide clarification to the salient characteristics for the brand name or equal. Part Number: XSS-41400-4801; Description: Xanadu 41.4TB (RAW) Raid Storage Systems, 4Gb FC-SAS/SATA-II Rackmount. Quantity: 2; Unit: Each Salient Characteristics: We need 2 (two) system with 41.4TB (raw) capacity each. Each system must have the following features: -Must have Dual Embedded 4Gb FC to SAS/ SATA-II RAID controllers, 2GB Cache Each (this means JBOD (just-a-bunch-of-disk) is not acceptable) -Must support active-active dual controllers configuration (this means the system requires dual redundant controllers) -Must support hardware RAID 5 and 6 -Must have Dual Hot Swap Redundant Power Supplies and Fans per Chassis -Must have Hot Swap IO Modules, Battery Units, and Management Interface Modules -Must be rack mount SAS / SATA-II Drive Chassis -Must be installed with at least 12 SAS drives with 15000 rpm and 450 GB capacity each (the drive configuration is stated here) -Must be installed with at least 36 SATA-II drives with 7200 rpm and 1TB capacity each (the drive configuration is stated here) -Must have redundant SAS/SATA Expansion (type of expansion chassis that is acceptable) -Must be scalable up to a maximum of 144 SAS/ SATA drives per system (the drive configuration is stated here) -Must have embedded management software that includes email alerts, snmp traps, access control, and path manager (mpio) -Must have dynamic provisioning -Must have parity checks on reads -Must have self healing drive technology -Must have zero rebuild time -Must support MAID (massive arrays of idle disks) energy saver if required -Must support Remote Data Replication if required -Must support Internal Replication & Snapshot if required -Must support Performance Monitor and Optimizer if required -Must have 3 years service agreement that include 24-hour advanced replacement parts
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/NB184000-9-06285/listing.html)
 
Record
SN01939064-W 20090905/090904000315-fc3631e8bfea736c6c22566466446ec7 (fbodaily.com)
 