SOLICITATION NOTICE
28 -- Replacement Programmable Logic Controllers
- Notice Date
- 9/1/2009
- Notice Type
- Cancellation
- NAICS
- 335314
— Relay and Industrial Control Manufacturing
- Contracting Office
- Department of the Navy, Naval Air Systems Command, Naval Air Warfare Center Aircraft Division Pax River, Building 441, 21983 Bundy Road Unit 7, Patuxent River, Maryland, 20670, United States
- ZIP Code
- 20670
- Solicitation Number
- 1300132264
- Archive Date
- 10/1/2010
- Point of Contact
- Carol L. Thomas, Phone: 3013426865, Susan M Holmes, Phone: 301-757-9744
- E-Mail Address
-
carol.thomas1@navy.mil, susan.holmes@navy.mil
(carol.thomas1@navy.mil, susan.holmes@navy.mil)
- Small Business Set-Aside
- N/A
- Description
- The Naval Air Warfare Center (NAWC) Aircraft Division intends to issue a contract on a SOLE SOURCE basis, under the Authority of FAR Part 13, to Rockwell Automation, 1 Allen-Bradley Drive, Mayfield Heights, OH 44124-6118 to purchase Allen Bradley Programmable Logic Controllers and other miscellaneous appurtenances. Delivery is required FOB destination to Propulsion Systems Evaluation Facility, Patuxent River Naval Air Station, Building 2360, 22229 Elmer Road, Patuxent River, MD 20670 no later than 30 November 2009. The Propulsion System Evaluation Facility (PSEF) is upgrading the testing capability in the Rotor Spin Facility (RSF) due to new requirements and obsolescence of most of the equipment. The RSF performs endurance tests of aircraft engine rotor and rotor assemblies. Currently, four test chambers in the RSF use 1980’s technology, Allen Bradley Programmable Logic Controllers (PLC) to control and monitor testing conditions and maintain system operational safety. Compatibility with the existing RSF’s Allen Bradley PLCs is mandatory. The Allen Bradley’s ControlLogix PLC is the latest generation of controller and is designed to connect and communicate with all the existing test hardware and support systems that work with it. The PSEF has internal support for the programming and maintenance of the Allen Bradley Control Logix PLC systems. All of the PLC equipment currently installed in the RSF is the older Allen Bradley products. These PLC systems are made up of power supplies, backplanes, input/output modules, etc. with wiring and consoles in place to support them. The new replacement Allen Bradley Control Logix PLC’s are the direct replacement controllers assuring compatibility and familiarity of control systems. In addition, all of the current PLC programs are written with proprietary software specifically for Allen Bradley PLC’s. For the safety of the test articles, test equipment and facility, the same PLC code is being used and the same type of system will be used due to compatibility. The Navy will be severely impacted should a failure occur due to usage of incompatible equipment and programs. Equipment under this contract will include: Model NumberDescription Qty. 1756-L63Logix5563 Processor with 8MGBYTE Memory4 1756-A44 Slot Controllogix Chassis 4 1756-PA72 85-265 VAC Power Supply (5V @ 10 AMP)4 1756-ENBTCLX Ethernet/IP 10/100 Bridge Module - Twisted Pair4 1756-N2Empty Slot Filler Card (1 card/pkg) 12 1794-AENTFLEX Adapter, Enet I/P 8 1794-IE8FLEX Analog, 12 BIT, 8 IN 8 1794-OE4FLEX Analog, 12 BIT, 4 OUT 8 1794-IB16FLEX 24VDC, 16IN SINK 8 1794-OW8FLEX Relay, 8 OUT, ISOL 8 1794-OB8EPFLEX 24VDC, 8OUT SRCE, Fuse, PROT 4 1794-TB3FLEX Terminal Base, 3-wire screw 36 1794-PS3FLEX PS, 24VD 3 AMP 8 1794-CE1FLEX EXT Cable, 1 ft 4 9355-WABGWENERSLINX Classic Gate CVB, English 4 1492-JT3M terminal block (pkg of 50 ) 2 1492-EBJ3TMEnd Barrier (pkg 20 ea.) 1 1492-PPJD3Partition Plate (pkg 20 ea.) 1 This synopsis is for informational purposes only. No RFP is available for competitive bidding; however, interested parties may submit a statement of capability for satisfying this requirement, to include descriptive literature to the contact person listed above. No phone calls. No split awards will be made. See note No. 22.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVAIR/N00421/1300132264/listing.html)
- Place of Performance
- Address: Propulsion System Evaluation Facility, Patuxent River Naval Air Station, Building 2360, 22229 Elmer Road, Patuxent River, Maryland, 20670, United States
- Zip Code: 20670
- Zip Code: 20670
- Record
- SN01935788-W 20090903/090902004515-864982bede6c84c8d69dc96e173a0ef0 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |