SOURCES SOUGHT
J -- MAINTENANCE FOR FIRE SPRINKLER SYSTEM
- Notice Date
- 8/30/2009
- Notice Type
- Sources Sought
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of Veterans Affairs;Veterans Healthcare System of the Ozarks; Purchasing & Contracting (90C);1100 N. College Ave.; Fayetteville AR 72703
- ZIP Code
- 72703
- Solicitation Number
- VA-256-09-RI-0433
- Response Due
- 9/4/2009
- Archive Date
- 11/3/2009
- Point of Contact
- PAUL GERTISERpaul.gertiser@va.gov
- E-Mail Address
-
Purchasing Agent
(paul.gertiser@med.va.gov)
- Small Business Set-Aside
- N/A
- Description
- THIS IS A SOURCES SOUGHT, HOWEVER IF YOUR COMPANY CAN PROVIDE THIS SERVICE, PLEASE PROVIDE A QUOTE FROM THE INFORMATION ON THIS RFI. THIS SERVICE IS FOR THE VA MEDICAL CENTER, FAYETTEVILLE, ARKANSAS 72703 Contract will begin October 1, 2009 through September 30, 2010. STATEMENT OF WORK SPRINKLER SYSTEMS 1.PER JOINT COMMISSION AND NFPA (72) QUARTERLY TESTING OF ALL SUPERVISORY SIGNAL DEVICES; AND OFF PREMISES EMERGENCY FORCES NOTIFICATION EQUIPMENT WRITTEN INSPECTION REPORT DELIVERED THE CHIEF OF ENGINEERING WITHIN 30 DAYS OF TESTING. 2.PER JOINT COMMISSION AND NFPA:SEMI ANNUAL TESTING OF APPROXIMATELY (82) SPRINKLER FLOW AND VALVE TAMPER DEVICES WITH APPROXIMATELY (42) CONTROL MODULES PER RECENT CHANGES TO NFPA DIRECTIVE WATER FLOW TESTING MUST BE COMPLETED UNDER FLOW CONDITIONS. MANUAL ACTIVATION OF THE DEVICE IS NOT ACCEPTABLE. WRITTEN REPORTS OF ALL TESTING AND INSPECTIONS SENT TO CHIEF OF ENGINEERING WITHIN 30 DAYS OF TESTS. 3.PER NFPA 72 REQUIREMENTS SEMI-ANNUAL TESTING OF THE KITCHEN AND CANTEEN EXTINGUISHING SYSTEMS, INSPECT FOR PROPER OPERATIONS. COPIES OF INSPECTION REPORTS SENT TO CHIEF OF ENGINEERING WITHIN 30 DAYS OF TEST. 4.PER NFPA (72) ANNUAL TESTING AS FOLLOWS: ALL DUCT DETECTORS, ELECTROMECHANICAL RELEASING DEVICES, HEAT DETECTORS, MANUAL FIRE ALARM BOXES (INCLUDES APPROXIMATELY (114) PHOTO DETECTORS, (52) HEAT DETECTORS AND (103) MANUAL PULL STATIONS) ALL ALARM NOTIFICATION DEVICES INCLUDING ALL AUDIBLE DEVICES, SPEAKERS, AND VISIBLE DEVICES. SPRINKLER SYSTEM MAIN DRAIN TEST AT ALL RISERS. FIRE ALARM SYSTEM BACKUP BATTERIES TESTED AT FULL LOAD FOR 60 OF FULL DURATION OF ITS CLASS. COPIES OF INSPECTION AND TESTING REPORTS SENT TO CHIEF OF ENGINEERING WITHIN 30 DAYS OF TEST. 5.PROVIDE ALL LABOR, PARTS, MATERIAL AND SUPERVISION TO REPAIR AND MAINTAIN MONITORING EQUIPMENT TO TRANSMIT FIRE ALARM SIGNALS FROM THE VA MEDICAL CENTER TO THE CENTRAL DISPATCH.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/FaVAMC564/FaVAMC564/VA-256-09-RI-0433/listing.html)
- Place of Performance
- Address: VA MEDICAL CENTER;1100 N. COLLEGE AVE.;FAYETTEVILLE, ARKANSAS
- Zip Code: 72703
- Zip Code: 72703
- Record
- SN01933426-W 20090901/090830233107-68dc024375cfbf3318f562ebb508a9ae (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |