SOURCES SOUGHT
J -- DRY PIPE INSPECTION FOR FIRE CONTROL
- Notice Date
- 8/30/2009
- Notice Type
- Sources Sought
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of Veterans Affairs;Veterans Healthcare System of the Ozarks; Purchasing & Contracting (90C);1100 N. College Ave.; Fayetteville AR 72703
- ZIP Code
- 72703
- Solicitation Number
- VA-256-09-RI-0434
- Response Due
- 9/2/2009
- Archive Date
- 11/1/2009
- Point of Contact
- PAUL GERTISERpaul.gertiser@va.gov
- E-Mail Address
-
Purchasing Agent
(paul.gertiser@med.va.gov)
- Small Business Set-Aside
- N/A
- Description
- THIS IS A SOURCES SOUGHT, HOWEVER IF YOUR COMPANY CAN PROVIDE THIS SERVICE, PLEASE PROVIDE A QUOTE FROM THE INFORMATION ON THIS RFI. THIS SERVICE IS FOR THE VA MEDICAL CENTER, FAYETTEVILLE, ARKANSAS 72703 Contract will begin October 1, 2009 through September 30, 2010. STATEMENT OF WORK DRY PIPE SYSTEM 1.PROVIDE ALL LABOR - MATERIAL - EQUIPMENT AND SUPERVISION TO TEST THREE (3) DRY PIPE SYSTEMS - WITH COPIES OF TESTING REPORT SENT TO CHIEF OF ENGINEERING WITHIN 30 DAYS 2.TEST FLOW RATE ON ALL FIRE HYDRANTS - SEND COPIES OF TESTING REPORT TO CHIEF OF ENGINEERING WITHIN 30 DAYS OF TEST. 3.QUARTERLY INSPECTION OF SIX (6) WET FIRE SPRINKLER SYSTEMS WITH COPIES OF TESTING REPORTS SENT TO CHIEF OF ENGINEERING WITHIN 30 DAYS OF TEST. 4.PERFORM ANNUAL DRY TRIP TEST WITH WRITTEN REPORT SENT TO CHIEF OF ENGINEERING WITHIN 30 DAYS OF TEST. 5.ANNUAL TESTING OF TWENTYFOUR BACK (24) FLOW PREVENTORS WITH TESTING REPORTS SENT TO CHIEF OF ENGINEERING WITHIN 30 DAYS OF TEST. 6.ANNUAL FIRE PUMP FLOW TEST SHALL BE CONDUCTED UNDER MINIMUM RATED AND PEAK FLOW CONDITIONS BY CONTOLLING THE FLOW OF WATER THROUGH AN APPROVED TEST DEVICE AS OUTLINED IN NFPA 25 PARAGRAPGH 5-3.31(A), B, OR C. AT ZERO FLOW THE PUMP COOLING FLOW AND SYSTEM RELIEF VALVE (IF INSTALLED) SHALL BE CHECKED FOR PROPER OPERATION. AT ALL FLOW CONDITIONS THE PUMP DRIVER OPERATING CONDITIONS WILL BE OBSERVED AND RECORDED. (ELECTRIC UNITS, ANP, VOLTS AND SPEED -- DIESEL UNITS OIL PRESSURE, WATER TEMPERATURE, AND SPEED). PUMP SUCTION AND DISCHARGE PRESSURE AND FLOW RATES WILL BE RECORDED. ALL ALARMS AND INDICATORS WILL BE OBSERVED AND ANY ABNORMALITIES RECORDED. AT RATED LOAD, BEARING VIBRATION READINGS WILL BE TAKEN AND RECORDED (ELECTRIC UNITS ONLY). AT PEAK LOAD, PUMP BEARING TEMPERATURES WILL BE RECORDED. TEST RESULTS WILL FIELD ACCEPTANCE TEST OR PREVIOUS YEARS FLOW TEST WHEN AVAILABLE TO DETERMINE THE ADEQUACY OF THE PUMP ASSEMBLY, AND ANY CHANGES IN ITS PERFORMANCE. 4 COPIES OF THE TEST REPORTS WILL BE DELIVERED TO THE ENGINEERING OFFICE FOR APPROPRIATE DISTRIBUTION. 7.WORK TO BE ACCOMPLISHED IN AUGUST OF FISCAL YEAR AND COMPLETED ON A SATURDAY FOR LOWEST INTERRUPTION OF VA MEDICAL CENTERS BUSINESS.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/FaVAMC564/FaVAMC564/VA-256-09-RI-0434/listing.html)
- Place of Performance
- Address: VA MEDICAL CENTER;11OO N. COLLEGE AVE.;FAYETTEVILLE, ARKANSAS
- Zip Code: 72703
- Zip Code: 72703
- Record
- SN01933425-W 20090901/090830233107-f4c0c34440f39391b305e49d67331b92 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |