SOURCES SOUGHT
J -- TO PERFORM GENERATOR LOAD BANK TESTING FOR 11 EACH EMERGENCY GENERATORS.
- Notice Date
- 8/4/2009
- Notice Type
- Sources Sought
- NAICS
- 541330
— Engineering Services
- Contracting Office
- Department of Veterans Affairs, Coatesville VAMC, Department of Veterans Affairs Medical Center, Department of Veterans Affairs;VAMC Coatesville;1400 Blackhorse Hill RD;Coatesville PA 19320
- ZIP Code
- 19320
- Solicitation Number
- VA-244-09-RQ-0377
- Response Due
- 8/14/2009
- Archive Date
- 8/24/2009
- Point of Contact
- Joseph SmithContract Specialist<br />
- E-Mail Address
-
Contact Contract Specialist
(Joseph.smith2@va.gov)
- Small Business Set-Aside
- Total Small Business
- Description
- The Coatesville VA Medical Center 1400 Blackhorse Hill Road, Coatesville, PA., intends to award this contract for generator maintenance and load bank testing services. The solicitation will be available ON or ABOUT August 10, 2009 to the Federal Business Opportunity Website.Notice of Set-Aside for Small Business Concerns: (a) the proposed contract is 100% set aside for small business concerns. Offers or proposals from other than small business concerns will be considered as back-up only. Statement of Work Emergency Generators Generator maintenance and load bank testing services are to be provided for the following generators. Generator maintenance will be conducted prior to load bank testing to allow time to correct any deficiencies identified (11generators). Located at VA Medical Center campus located at 1400 Blackhorse Hill Road Coatesville, PA 19320. BUILDING 75(1977) Kohler Generator Set - 120/208 3 Phase-Nameplate Rating -799 AMPS BUILDING 81(1977) Kohler Generator Set - 120/208 3 Phase-Nameplate Rating = 799 AMPS BUILDING 139 (1986) Onan Generator Set - 277/480 3 Phase-Nameplate Rating = 400 AMPS BUILDING 138 (1981) Empire Generator Set - 120/208 3 Phase Nameplate Rating = 570 AMPS BUILDING 71 (1977) Kohler Generator Set - 120/208 3 Phase-Nameplate Rating = 799 AMPS BUILDING 100 (1985) Onan Generator Set - 277/480 3 Phase-Nameplate Rating = 600 AMPS BUILDING 14(2001) Detroit Diesel Generator Set - 277/480 3 Phase-Nameplate Rating = 800 AMPS BUILDING 79 (1977) Kohler Generator Set - 120/208 3 Phase-Nameplate Rating = 799 AMPS BUILDING 63 (1990) Onan Generator Set - 277/480 3 Phase-Nameplate Rating = 750 AMPS BUILDING 1(1994) Onan Generator Set - 120/208 3 Phase-Nameplate Rating = 799 AMPS BUILDING T-21 Spectrum Detroit portable generator, Model 220DSE Load Bank Testing Fiscal Year 10-1-09 thru 9-30-10 Work to be completed prior to 2-28-10 Work to be performed between the hours of 8am thru 4:30pm Monday thru Friday load bank testing on the generators listed above. Load bank testing to meet Joint Commission on the Accreditation of Healthcare Organizations (JCAHO). JCAHO requirements 25% of the name plate rating for 30 minutes 50% of the name plate rating for 30 minutes 75% of the name plate rating for 1 hour 30% of the name plate rating for 2 1/2 hours Total 4 '/2 hour load bank test for each generator Provide 2 copies of all load bank testing reports to the General Properties Supervisor. Generator Maintenance Fiscal Year 10-1-09 thru 9-30-10 Work to be completed prior to 1-30-10 Work to be performed between the hours of 8am thru 4:30pm Monday thru Friday Maintenance on the generators listed above. Timing to be checked and set if necessary Equipment to be lubricated Oil and oil filters changed Fuel tanks and fuel lines to be inspected for excessive sludge, rust, water or deterioration fuel filters to be changed, sediment bowls cleaned Inspect entire units for fuel and water leaks Provide 2 copies of all recommended maintenance required to he completed prior to the load bank testing that is not required by this contract to the General Properties Supervisor.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/CoVAMC542/CoVAMC542/VA-244-09-RQ-0377/listing.html)
- Place of Performance
- Address: Department of Veterans Affairs;VAMC Coatesville;1400 Blackhorse Hill RD;Coatesville PA<br />
- Zip Code: 19320<br />
- Record
- SN01898562-W 20090806/090805000055-1aa952b3deaaa2100755eaf5eb527375 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |