Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 30, 2009 FBO #2803
AWARD

Y -- RECOVERY--Y--ROOF REPAIR BUILDING P-4475 ARMY FORT DRUM

Notice Date
7/28/2009
 
Notice Type
Award Notice
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Army, Army Contracting Agency, North Region, ACA, Fort Drum, ACA, Fort Drum, Directorate of Contracting, 45 West Street, Fort Drum, NY 13602-5220
 
ZIP Code
13602-5220
 
Solicitation Number
EC-00509-9J
 
Response Due
7/27/2009
 
Archive Date
9/25/2009
 
Point of Contact
Barbara Hunt, 315-772-9050<br />
 
E-Mail Address
ACA, Fort Drum
(barbara.hunt@us.army.mil)
 
Small Business Set-Aside
N/A
 
Award Number
W911S2-06-D-0005-0056
 
Award Date
7/24/2009
 
Awardee
Chugach Industries Incorporated<BR>3800 Centerpoint Drive, Suite 601<BR>Anchorage, AK 99503
 
Award Amount
3,135,965.17
 
Line Number
2001
 
Description
This contract action was accomplished using other than competitive procedures because this is an order under an existing contract that was awarded using non-competitive procedures. RECOVERY: This firm fixed price task order number 56 was awarded under Contract W911S2-06-D-0005 to Chugach Industries Incorporated and funded by the American Recovery and Reinvestment Act (ARRA) of 2009. Rationale for this action is as follows: The existing contract is one of two contracts awarded under the authority of the SBA 8 (a) program for the repair, rehabilitation and construction services. The contract is one of the primary means of providing quick and responsive contract support to accomplish installation minor construction workload priorities and surges. To ensure the intent of the Recovery Act is met, this contract provides the most expeditious and efficient method of expending Recovery Act funds. Numerous subcontracting opportunities are associated with this contract. The work shall include all work in connection with roof repair Building P-4475 Army Fort Drum, New York. Work shall include, but is not limited to replacing the overhead doors, replace all exterior personnel doors and frames, replace one light pole in the storage yard, upgrade the central bathroom ( mens and womens) by installing new toilets, toilet partitions, urinals, sinks, mirrors, light showers and bring the bathroom up to ADA capable. Roofs to be replaced will be EPDM on two (2) buildings with the metal slope roof dropping into a roof gutter. The existing lube pits shall be upgraded by adding fiberglass grate and lighting shall be updated to include fluorescent lighting units in the pit. The ceilings, walls and floor surfaces shall be painted. The floor in the warehouse shall be primed with epoxy mastic paint and slip resistant. Acoustical ceiling shall be removed including the grid system and replaced with new acoustical ceiling tile. The floor tile shall be removed and replaced with new 1/8 vinyl composition tile with the color to be picked by Public Works. The vinyl base shall be installed where VCT tile is installed. The electrical interior portion includes removing lights as indicated on the concept drawing and replaced with new. The exterior pavement around the VMF shall be milled down (asphalt only) 1.5 inches, tack coat placed and asphalt top placed. In the existing repair bays where water and compressor air is available, install new hose reels at existing locations to accommodate a water and compressed air reel and fan at each bay. In the existing repair bays at each overhead door install a new vehicle exhaust reel (2 per bay) similar to the ones installed in VMF 10265, remove existing ductwork for each vehicle exhaust and remove and fix and seal outlets to the outside. One of the bays shall be designed as a welding bay and welding curtains and exhaust fan shall be installed similar to the welding bay in VMF 10265. In the repair bay the existing boiler shall be replaced with a KN brand sized to the area to be heated. The fire detection system shall be upgraded to current NFPA, 70, NFPA, 72, NFPA, 101 and UFC-3-600-01 standards to include smoke detectors, fire alarm panel, pull stations, emergency lighting, visual signals, and mass notification system. The out buildings that are not connected to the fire alarm system shall be updated. The damaged siding on the overhead doors shall be replaced with similar metal siding and the color to match existing. The damaged bollards shall be straightened or replaced and a plastic cover placed over them. Five (5) gates shall be replaced and 400 lineal feet of fence. The eye wash/shower stations in the hallway by the west vestibule and in Room 106 shall be removed shall not be replaced. The eye wash/shower stations to be replaced are located in the following areas; (one (1) in the warehouse, two (2) in each maintenance bay, one (1) at each lube pit and one (1) in the west battery Room 131. Fire extinguishers shall be installed per code throughout the building. In the two oil water separator rooms on the south end of the repair bays, replace the oil water skimmers. In the entrance vestibule, remove and replace the grating with new including cleaning under the grating of any soil or debris before replacing new grate. Remove existing wire cage in the area of the maintenance bay by the pit to allow access to the used oil and used antifreeze storage area.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/DABJ/DABJ17/EC-00509-9J/listing.html)
 
Record
SN01890841-W 20090730/090729001032-57e435fc69c557d684dc1648660d5e56 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.