MODIFICATION
66 -- DIGIAL AUTOCOLLIMATOR
- Notice Date
- 7/28/2009
- Notice Type
- Modification/Amendment
- NAICS
- 333314
— Optical Instrument and Lens Manufacturing
- Contracting Office
- NASA/Goddard Space Flight Center, Code 210.M, Greenbelt, MD 20771
- ZIP Code
- 20771
- Solicitation Number
- NNG09303309Q
- Response Due
- 7/31/2009
- Archive Date
- 7/28/2010
- Point of Contact
- Rogenia Burton-Pendergast, Simplified Acquisition Specialist, Phone 301-286-7587, Fax 301-286-1720, Email Rogenia.M.Burton-Penderga@nasa.gov - Eric Jackson Newman, Contracting Officer, Phone 301-286-1892, Fax 301-286-1720, Email Eric.J.Newman@nasa.gov<br />
- E-Mail Address
-
Rogenia Burton-Pendergast
(Rogenia.M.Burton-Penderga@nasa.gov)
- Small Business Set-Aside
- Total Small Business
- Description
- THIS NOTICE CONSTITUTES AMENDMENT NO. ONE (1) TO THE COMBINED SYNOPSIS/RFQ FORDIGIAL AUTOCOLLIMATOR.Companies shall acknowledge all amendment(s) in their quote. Thisnotice serves as the official amendment to subject synopsis/RFQ and a written amendmentwill not be issued.The purpose of this amendment is to respond to vendor questions.The due date for receipt of offers is not extended.Q1. Working with a manufacturer who raised the points below regarding the autocollimatoryou are requesting. And in order to provide you with the best quote possible quote, Ihope you can follow-up with me.The T160HR is not the model that is recommended for a target that is only 5 mm. TheT160HR beam diameter is 30 mm so only a very small % reflection would be obtained from a5 mm mirror. Instead, recommendation is for a mirror of at least 50 mm for use with aT160HR. For a 5mm target at 2 meters, the recommendation is for a TL160HR. This autocollimatoruses a laser light source with a 10 mm diameter emitted beam.A 5mm diameter target isstill not ideal but should at least provide an adequate signal. It should have a rangeof about +/- 300 arc-seconds at a working distance of 2 meters.All of the data acquisition is done via the E3 controller which has analog outputs foreach axis, an RS-232 serial interface and a digital display. For measurements up to 500readings-per-second the RS-232 can be used. For readings up to 4000 readings-per-secondthe analog outputs should be used.Of course, the T160HR can be provided, but I wanted to make you aware of these points andask your thoughts.A1: The TL160 HR would be acceptable, and would meet our requirements.Companies shall provide the information stated in the synopsis/RFQ posted on the NASAAcquisition Internet Service (NAIS) on 07/16/2009. Documents related to this procurementare available over the Internet. These documents reside on a World Wide Web (WWW) serverwhich may be accessed using a WWW browser application. The Internet site, or URL, for theNASA/GSFC Business Opportunities home page ishttp://prod.nais.nasa.gov/cgi-bin/eps/bizops.cgi?gr=D&pin=51
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/NASA/GSFC/OPDC20220/NNG09303309Q/listing.html)
- Record
- SN01890642-W 20090730/090729000800-3f94f6b11540d27dd822b24cad3b2229 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |