Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 15, 2009 FBO #2788
SPECIAL NOTICE

A -- Sole Source Purchase of a FT-Raman Spectrometer "MultiRam"

Notice Date
7/13/2009
 
Notice Type
Special Notice
 
NAICS
541380 — Testing Laboratories
 
Contracting Office
Department of Agriculture, Forest Service, Forest Products Laboratory, One Gifford Pinchot Drive, Madison, Wisconsin, 53705-2398
 
ZIP Code
53705-2398
 
Solicitation Number
301302
 
Archive Date
8/20/2009
 
Point of Contact
John M Belovsky, Phone: 608-231-9285
 
E-Mail Address
jbelovsky@fs.fed.us
(jbelovsky@fs.fed.us)
 
Small Business Set-Aside
N/A
 
Description
We intend to purchase a MultiRam and RamScope III from Bruker Optics, Inc., 19 Fortune Drive Billerica, MA 01821with accessories. The required salient qualities are: 1 RFS27 FT-Raman Spectrometer "MultiRam" Flexible rapid scanning spectrometer for FT-Raman applications in the analytical and research laboratory. Equipped with an extensive analytical software package. The spectrometer is suitable for the collection of Raman spectra with laser excitation at 1.064μm. To make up a complete system the following components are required: - Filter set F452 - Laser for Raman-excitation with adaptations, R510-N (500mW) or R513-1000/R (1W) - Detector with adaptations D424/0 or D418-T/R27(A detector of D418 type is highly recommended). Optionally the instrument can be configured with a second measurement channel for a second excitation line, for details see Multiram specifications and options. For control of the spectrometer optics and signal processing a PC-based data system which might be quoted below is required (we recommend to order the data system with the spectrometer optics in order to make sure that the system performes flawlessly). The requirements for a suitable data system are available on request. Raman: Sources 2 R513-1000/R Nd:YAG LASER, diode pumped, P=1000mW 1220004716 Recommended: - Laser safety goggles, see R573-1064DL5 Depending on measurement device and application leaking of Laser radiation is possible. In case of Laser class 3B and 4 products the operating company has to cater for appropriate protective equipment. Raman: Detectors 3 D418-T/R27 Ge detector (liquid N2 cooled), long hold time, NIR, high sensitivity design, liquid nitrogen hold time >5days incl. adaptations Raman: Filters 4 F452 Laser rejection filter system for filtering the exciting laser radiation and for suppression of the laser radiation mixed into the Raman signal (primary and secondary filter) for 1064 nm excitation (for use in channel 1 only) 5 R201 Extension of spectral range to 50cm-1 Stokes Shift Raman: Ext. Measurements. Channels 6 R353/R Input port for Raman radiation (E3) via fiber optic cable SMA connector, computer controlled 7 R356-1/R Exit Port for Laser Radiation (X6), computer controlled Raman: Focusing Units 8 R531/R Expansion of laser beam for reduction of the power density of the exciting laser radiation for use with highly absorbing materials. The accessory is operated under computer control. Raman: Sample Stage 9 R313MHRU Upgrade to motorized xyz-sample stage; motorized translation stage, translation 9.5mm for each axis, stepsize 50μm vertical and horizontal sample holder; requires R348/R or R348-VA/R for horizontal sample holder in lieu of standard sample stage, surcharge 1220004716 Raman: Focusing units mic. 10 R293-F1 Servo-assisted z-Control including Autofocus-Function required: computer controlled stage R293-U Raman: Microscope 11 R590/R RAMANSCOPE III, FT-Raman microscope For the investigation of small sample areas with the NIR-FT-Raman technique (operating with 1064nm laser radiation). The microscope is designed to be easily connected to the BRUKER FT-Raman module FRA106/S, RAMII or the FT-Raman spectrometers MultiRam, RFS100/S via fiber optic cables. Maximum distance between spectrometer and Raman microscope: 1.5m (other distances available on request) The Ramanscope III includes: 1. Olympus BX51 reflected light microscope with: - DF/BF illuminator - trinocular head with eye pieces• - digital color video camera - manual XY stage - 40x objective mounted on quintuple nosepiece 2. Raman microscope attachment with: - Coupling module for use with 1064nm excitation, - optical fibers for guiding radiation from Raman laser and Raman scattering, - enclosure: Class 1 Laser Safety with interlocks, (the RAMANscope III is classified as a Laser Class 1 device in standard configuration) 3. OPUS/VIDEO Required: - R353/R and R356-1/R for connection with MultiRam or RAMII; - R354 and R355 for connection with FRA106; - R353/0 and R355/0 for RFS100 - Detector D418-T - Data system with USB 2.0 port Raman: Sample Stage Microscope 12 R293-SU Computer controlled sample stage Adjustment range: 75mm x 50mm Adjustment accuracy: 0.1μm Repeatability: better 1μm 1220004716 Requires: OPUS/MAP and OPUS/3D software in lieu of standard (manual) stage, surcharge OPUS Spectroscopy Software 13 O/IR+ OPUS/IR, FT-IR Spectroscopy Software Package This software package is included in the delivery of a spectrometer. 14 O/3D-N OPUS/3D, Software package for 3D data processing, 1GB RAM recommended 15 O/MAP-N OPUS/MAP, software package for control of x-y sample stages. 16 O/SR-N OPUS/SEARCH, Extended Search Software Package For editing structures and structure search the OPUS/STRUCTURE package is required. Data Systems 17 CS81/21-E Data system, "intel" Core 2 Quad processor, >2,4GHz, 2GB RAM and 250GB HDU or better, 16x DVD+/-RW Drive, 19" TFT display, 2 network interfaces, Windows XP Professional. (only available with oder of spectrometer) Services with orders 18 S950+ Installation on-site included in the price of the system (including travel charges, inland) 1220004716 OPTIONAL ACCESSORIES: Raman: Polarizers 19 R566/R Polarizing accessory for RAMII and Multiram including a computer controlled filter changer W103/R with 2 NIR polarizers F441 Note: Use of a half wave plate (R595/x) is recommended. 20 R595/R 1 PCE 4,118.00 Half waveplate, 1064nm with computer controlled rotation unit. Note: The use of a polarization accessory R566/R is recommended. Raman: Focusing Units 21 R530/R 90° Excitation of Sample; computer controlled switching Raman: Var. Temp. Units 22 A599 Heatable sample stage; can also be used inside the sample compartment, maximum temperature: 180°C Controller with RS232-interface and interface cable are included. The temperature of the sample can be controlled manually or by the OPUS software. Accessory can be used for Raman or FT-IR Microscopy. For use with FT-Raman sample compartment A599-HM is required (for FRA106 or RFS100 R599-H). A set of BaF2-windows and an O-ring are included. 23 R495/R Raman low temp.cell (ambient -120°C) for NMR-tubes flow through control Includes: 30l dewar, heater, flow regulator and custom sample compartment lid. Requires liquid N2, R495-H (for capillaries only) 24 R599-HM Adaption of A599 to MultiRAM and RAM II, including motorized x-translation stage R311-M Raman: Automation Units 25 R315/R Mapping stage xy, 50 x 75 mm, for TLC measurements requires: R348/R or R348-VAR OPUS/MAP OPUS/3D 26 R315-HTS 1220004716 HTS-Mapping Stage X, Y-Mapping Stage for High Throughput Raman Applications including mirror objective. The stage accepts well plates in standard sizes (127.8mm x 85.5mm). Samples are analyzed from below. Required: - OPUS/MAP - OPUS/3D - OPUS/LAB - A754-96 27 A754-96 Microplate, 96 wells (5 pieces), black plastic with glass bottom, for transmission measurements in the NIR and FT-Raman measurements Raman: Objectives 28 R348-VAR Video Accessory The FT-Raman Video Accessory displays an image of the sample on the PC display. It allows viewing of the sample mounted on a horizontal sample stage while the sample compartment lid is closed. Both, laser radiation incident on the sample and the sample can be seen simultaneously. The accessory includes a CCD camera attached to a mirror objective with 33mm focal length, Frame grabber and sample illumination. Requirements: R313-MH computer controlled/motorized xyz stage or R315/R TLC FT-Raman stage Data system with USB-interface OPUS vers. 6.5 SP1 or higher Optional: O/VID-N OPUS/Video Specifications: Field of view: ca 9mm dia. Available with instrument order only Warranty All standard products sold and manufactured by Bruker Optics Inc (hereinafter called "BOPT") carry a limited warranty, subject to the terms and conditions hereby set forth. Spectrometer systems are warranted for one year to be free of defects in material and workmanship. Services, parts, and accessories purchased separately from systems are warranted for 90 days. The applicable warranty period for Products shall begin upon demonstration of specifications but not more than 18 months from delivery. The applicable warranty period for Accessories (other than those purchased with a complete system) shall begin upon delivery. Installation Systems include installation unless otherwise noted. Parts and accessories do not include installation unless otherwise noted. If there are any potential vendors that have the afore mentioned salient qualities or better and are interested in being considered, contact Mr. Mike Belovsky prior to the deadline. Be prepared to present your product for consideration.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USDA/FS/5680/301302/listing.html)
 
Place of Performance
Address: USDA, Forest Service, Forest Products Laboratory, One Gifford Pinchot Drive, Madison, Wisconsin, 53726, United States
Zip Code: 53726
 
Record
SN01873616-W 20090715/090713235847-0d20659fde207e6eecdaa4f59b317450 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice