SOLICITATION NOTICE
54 -- WALK-IN COOLER FACILITY KIT - RFQ for Walk-In Cooler Facility Kit
- Notice Date
- 6/29/2009
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 332311
— Prefabricated Metal Building and Component Manufacturing
- Contracting Office
- Department of the Air Force, Air Combat Command, 1st CONS, 74 Nealy Avenue, Suite 100, Langley AFB, Virginia, 23665
- ZIP Code
- 23665
- Solicitation Number
- W91B4K-09-T-3021
- Archive Date
- 7/25/2009
- Point of Contact
- Christina Gunderman,
- E-Mail Address
-
christina.gunderman@afghan.swa.army.mil
(christina.gunderman@afghan.swa.army.mil)
- Small Business Set-Aside
- N/A
- Description
- Specifications for Walk-In Cooler Facility Kit Solicitation for Walk-In Cooler Facility Kit Overall facility: 2600 square feet and/or 26000 cubic feet Freezer: 1300 square feet and/or 13000 cubic feet Refrigerated: 800 square feet and/or 8000 cubic feet Dry storage/vestibule: 500 square feet or 5000 cubic feet Operating Conditions: Facility must operate in outdoor ambient 120 degrees Fahrenheit at average 60% relative humidity, maintaining freezer temperature of -10F degrees, refrigerated storage of +35F, and dry storage/vestibule temperature of +70F degrees. Some product will enter the facility at ambient outdoor temperature, some will enter at chilled temperature. Construction Materials: Facility must be a “kit” that can be installed by construction personnel not necessarily trained in erection of this particular type of structure. Facility shall consist of all materials and be self-contained for erection in a harsh outdoor climate (does not need to be placed inside of another facility). At a minimum, facility shall have a sloped roof and be able to withstand sun/wind/precipitation/extreme heat and cold. Facility shall include all materials, engineered drawings, and instruction manuals necessary for preliminary foundation/slab construction and erection of facility to include minimum components: structural, insulation, doors, controls, cooling systems (to include refrigerant). Interior and exterior surfaces shall have a rigid and glossy finish in order to facilitate cleaning Electrical Power Source: 3-phase, 60 Hz Lighting: Facility must include an interior lighting system. Doors: Facility kit shall include a necessary number of minimum 8 foot wide bi-parting powered sliding doors. Access to the refer/freezer should be only from the dry storage/vestibule area to minimize air transfer. (2) hinged doors shall also be included, in accordance with the attached conceptual drawings. Shipping: Facility “kit” shall be shipped in shipping containers and include shipping to nearest military port facility for transportation through military channels to Afghanistan.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/ACC/1CONS/W91B4K-09-T-3021/listing.html)
- Place of Performance
- Address: FOB Fenty, Jalalabad, Afghanistan, APO, Non-U.S., 09310, United States