MODIFICATION
J -- RECOVERY--J--Install, Rehabilitation, and Fabrication of Stop-Logs.
- Notice Date
- 6/26/2009
- Notice Type
- Modification/Amendment
- NAICS
- 332312
— Fabricated Structural Metal Manufacturing
- Contracting Office
- Department of the Army, U.S. Army Corps of Engineers, U.S. Army Engineer District, Kansas City, US Army Engineer District, Kansas City, ATTN: CENWK-CT, 700 Federal Building 60l East 12th Street, Kansas City, MO 64106-2896
- ZIP Code
- 64106-2896
- Solicitation Number
- W912DQ09R1026
- Response Due
- 7/6/2009
- Archive Date
- 9/4/2009
- Point of Contact
- WILLIE HODGES, 816 389-3469<br />
- E-Mail Address
-
US Army Engineer District, Kansas City
(willie.e.hodges@usace.army.mil)
- Small Business Set-Aside
- Total HUB-Zone
- Description
- RECOVERY--THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO CONTRACTORS UNDER W912DQ09R1026. This is a revised Sources Sought posting from June 19, 2009. This is a SOURCES SOUGHT SYNOPSIS. This is a Source Sought Synopsis announcement; market survey for information only, to be used for preliminary planning purposes. No proposals are being requested or accepted with this synopsis. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. The U.S. Army Corps of Engineers Kansas City District has been tasked to provide the work in this contract involves fabricating stop-logs without J-bulb seals (which will be referred to as water supply barriers), and rehabilitating existing stop-logs and aperture. Fabricating the water supply barriers, in this contract will require (but is not limited to): precision machining of 8-3 by 3-4 by 1 1 wide steel structure weighing about 1800 lbs each, weldment fabrication by a certified welder meeting AWS D1.1 standards, weldment inspection by a certified weld inspector, and vinyl painting. The rehabilitated stop-logs will require (but are not limited to) the following: removal of galvanized coating, precision machining for 8-3 by 3-4 by 1 1 wide steel structures weighing about 2500 lbs each, J-bulb seal replacement, weld repair to AWS D1.1 standards using prequalified weld procedures, weldment inspection by a certified weld inspector, and hot-dip galvanizing. The rehabilitated aperture is 8-3 by 2-7 by 1 1 wide steel structure weighing about 1000 lbs. It will require (but is not limited to) the following: removal of galvanized coating, weld repair to AWS D1.1 standards using prequalified weld procedures, weldment inspection by a certified weld inspector, and vinyl painting. Removal and/or Installation, by crane, of all steel structures mentioned above is required. American Recovery Reinvestment Act funds will be used for this action. Send a brief resume describing your qualifications for the Scope of Work mention above. Email resume to a Mr. Hodges at willie.e.hodges@usace.army.mil. This is a revised Sources Sought posting from June 19, 2009.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA41/W912DQ09R1026/listing.html)
- Place of Performance
- Address: US Army Engineer District, Kansas City ATTN: CENWK-CT, 700 Federal Building 60l East 12th Street Kansas City MO<br />
- Zip Code: 64106-2896<br />
- Zip Code: 64106-2896<br />
- Record
- SN01858848-W 20090628/090627001632-708f3a5890a615a54caffc61dfea68c4 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |