Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 19, 2009 FBO #2762
SPECIAL NOTICE

70 -- Portable Multifunctional Data Acquisition System

Notice Date
6/17/2009
 
Notice Type
Special Notice
 
NAICS
334515 — Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
 
Contracting Office
Department of the Army, Army Contracting Agency, South Region, ACA, White Sands Missle Range, ACA, White Sands Missile Range, Directorate of Contracting, Bldg 143, 2nd Floor, Crozier Street, White Sands Missile Range, NM 88002-5201
 
ZIP Code
88002-5201
 
Solicitation Number
W9124Q-09-P-0183
 
Archive Date
9/15/2009
 
Point of Contact
Monica E. Barrera, 575-678-1371<br />
 
E-Mail Address
ACA, White Sands Missile Range
(monica.e.barrera@us.army.mil)
 
Small Business Set-Aside
N/A
 
Description
The Mission & Installation Contracting Command at White Sands Missile Range, NM 88002 intends to award Contract No. W9124Q-09-P-0183 under NAICS code of 334515 to a small business set aside in the amount of $48,975.00, under the authority of FAR 13.106-3 (a)(1), to Dewetron, Inc., 10 High Street, Ste K, Wakefield, RI 02879 to purchase a DEWE-5000 Portable Multifuncitonal Data Acquisition System CLIN 0001. Qty. 1 DEWE-5000, Portable multifunctional data acquisition system, 16 internal amplifier slots for DEWETRON DAQ / PAD series modules, SUB-D-37 socket for digital signals of 1st installed DEWE-ORION card, Lemo EGG.1B.304 socket for EPAD, 17 TFT display 1280 x 1024 pixel, 2 GHz Intel Core2Duo processor, 1 GB RAM, 400 GB HDD, DVD +-RW drive 4 x USB, 1x RS-232, 2x LAN Ethernet, Power supply 115 / 230 VAC, Microsoft Windows XP Professional operating system, 5 free PCI slots (4 full length and 1 half length), A/D card(s) and DAQ / PAD modules must be ordered separately. Qty. 1 ORION-1624-200, 16 channel DEWETRON PCI A/D card, 24-bit resolution, simultaneous sampling, 204.8 kS/s per channel, anti-aliasing filters; 8 synchronous TTL digital I/Os; 2 synchronous advanced TTL counter / encoder or 8 TTL digital inputs; Qty. 1, IRIG-CLOCK-INT, IRIG synchronized clock source for A/D boards, installed inside a new DEWETRON base unit, Frequency range: 10 Hz to 10 MHz, Clock accuracy IRIG locked: without drift, Clock accuracy IRIG unlocked: 1 ppm, Input: IRIG code A or B, AM or DC, Occupies one USB interface, Requires DEWESOFT-x-PROF (or higher). Qty. 1, DEWESoft-6-PROF Complete turn-key data acquisition software package, PROFESSIONAL version. Easy to use, optimized for DEWETRON systems, includes recorder, scope, trigger capabilities, FFT analysis, data storage and export, data analysis and report functions. Drivers for DEWETRON, National Instruments, Data Translation, Spectrum and Microstar DAP boards. Supports multiple A/D cards of the same type. Supports hardware synchronized video support, supports multiple video cameras of the same type. Qty. 1 DEWESoft-OPT-NET DEWESoft Network data acquisition including remote control allows complete remote controlled setup as well as forward the raw data of selected channels via the network; Requires DEWESOFT-x-PROF, Note: Each Dewetron measuring instruments which are intended to be used in a DEWE-NET topology need to have DEWESoft-6-PROF (or higher) plus DEWESOFT-OPT-NET software installed. If the Dewetron measuring instruments have a common time sync, then a separate computer also running DEWESoft as a master client can control the measuring instruments remotely, and pick combinations of channel(s) from any of them for display on the client (up to the aggregate bandwidth of the network). Neither the master client nor any view clients, require these Dewesoft software licenses -- however the licenses are needed on each Dewetron measuring instrument. Qty. 16, DAQP-LV-BNC Medium voltage input module, ranges and filters programmable, isolated voltage inputs, selectable ranges 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2.5, 5, 10, 25, 50 V, bipolar or unipolar, AC or DC coupling, bandwidth DC to 300 kHz, selectable filters 10, 30, 100, 300 Hz, 1k, 3k, 10k, 30k, 100k and 300 kHz, filter characteristic butterworth or bessel (300 kHz Bessel only), accuracy typ. 0.05 %, connector: BNC; plus shipping cost, CLIN 0002. The contract award date is set for 18 June 2009. This is not a request for quotations. No Solicitation or RFQ will be forthcoming. Interested parties must respond by 2:00 PM MST, 18 June 2009 to the point of contact Monica Barrera by facsimile at (575) 678-5107 or email monica.e.barrera@us.army.mil.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/DABK/DABK39/W9124Q-09-P-0183/listing.html)
 
Record
SN01847730-W 20090619/090617235506-62285946dc1888c28ea4cd84a33ec82f (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.