MODIFICATION
Y -- RECOVERY - Maintain Roof, Research Equipment Storage Building 4444
- Notice Date
- 6/11/2009
- Notice Type
- Modification/Amendment
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, 95 CONS, 5 South Wolfe Avenue, Edwards Air Force Base, California, 93524
- ZIP Code
- 93524
- Solicitation Number
- FA930104D0025-FSPM051371
- Point of Contact
- Cheryle E Armstrong, Phone: 661-277-8356
- E-Mail Address
-
cheryle.armstrong@edwards.af.mil
(cheryle.armstrong@edwards.af.mil)
- Small Business Set-Aside
- 8a Competitive
- Description
- RECOVERY - THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO CONTRACTORS UNDER THE SIMPLIFIED ACQUISITION ENGINEER REQUIREMENTS (SABER) CONTRACT NUMBER FA9301-04-D-0025. Contractor: Ace Engineering, Inc. 1800 Wright Avenue, La Verne, CA 91750-5824. It is the Contracting Squadron's intent to award firm-fixed price task orders to the above contractor. Davis-Bacon wages presently in effect for California. CA070013 (Modification 13) dated 11/23/2007 and CA070031 (Modification 17) dated 11/23/2007 will prevail. These acquisitions are subject to the North American Industry Classification Code 238990 and the annual size standard is $14.0 million. FSPM051371 - Maintain Roof, Research Equipment Storage Building 4444 THE PROJECT DESCRIPTION IS AS FOLLOWS: The work to be accomplished to furnish all labor, materials, equipment, and supervision required to repair the built-up/shingle roof Building 4444. Remove existing built up/shingle roof and insulation, asbestos containing roof mastic, unused penetrations (including curbs) and drip edges. Replace damaged wood deck areas and install new plywood deck. Install tapered insulation system with a minimum of R-19. Install 1/4" dens-deck. Install single ply PVC roofing system. Replace metal flashings and drip edges with new prefinished metal. Paint roof equipment (Marble Cream) and facia (Redwood). Roof mastics around penetrations are positive for asbestos. For roofs with a slope of 2:12 or less - "Use roofing materials having a Solar Reflectance Index (SRI) equal to or greater than 78. "For roof with a slope greater than 2:12 - "Use roofing materials having a Solar Reflectance Index (SRI) equal to or greater than 29". This facility is located at Edwards Air Force Base, California.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/12345/FA930104D0025-FSPM051371/listing.html)
- Place of Performance
- Address: 5 South Wolfe Avenue, Edwards AFB, California, 93524, United States
- Zip Code: 93524
- Zip Code: 93524
- Record
- SN01842264-W 20090613/090611235344-58bdd1f33c6a84f067e46cb326e4f153 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |