SOLICITATION NOTICE
54 -- Updated Statement of Work
- Notice Date
- 4/15/2009
- Notice Type
- Modification/Amendment
- NAICS
- 238390
— Other Building Finishing Contractors
- Contracting Office
- Department of the Army, National Guard Bureau, 141 ARW/LGC, WASHINGTON AIR NATIONAL GUARD CONTRACTING OFFICE, 141 ARW/LGC, Washington Air National guard Contracting Office, 2 South Olympia Avenue, Fairchild AFB, WA 99011-9439
- ZIP Code
- 99011-9439
- Solicitation Number
- F6T8SR9043A002
- Response Due
- 4/21/2009
- Archive Date
- 6/20/2009
- Point of Contact
- Matthew Richard, 509-247-7223<br />
- Small Business Set-Aside
- Total Small Business
- Description
- This is the updated statement of work This will supercede all other Statement of Works Direct all questions to matthew.richard@ang.af.mil or (509) 247-7223 Bid Close date is still April 21, 2009 @ 4:00 P.M. PST All other rules and regulations pertaining to the FAR still apply STATEMENT OF WORK FOR THE PURCHASE AND INSTALLATION OF WALL PARTITIONS Revised 15 Apr 2009 1.0 SCOPE 194th Intelligence Squadron (IS) requires the purchase and installation, connection and finish work to complete a total of eight complete private office spaces of various sizes with doors to include allowance for a single electrical/network box per wall and allowance to route wiring from floor. See below diagram for approximate power/network drop locations. Existing ceiling is approximately 8 ft suspended utilizing 2ft x 4 ft drop in tiles. Existing structural beams do exist in the perimeter walls and have potential to impact configuration and installation. Note: All, final measurements shall be verified by awarded contractor prior wall installation. 2.0 BACKGROUND 2.1 The contractor will determine suitable partition wall materials for this project in accordance with this SOW. The partitions must have the following options: multiple segmented, sound damping, raceway panel configurations, with options of multiple complementary fabrics, wood laminates, vented, or whiteboard surfaces, partitions must make complete, floor to ceiling private office spaces with locking full width doors, and reception stations. All connections are integral to the extruded aluminum frame. Universal connector posts work for all same- and multi-height connections, to allow for reconfiguration of partitions. Less than ceiling height panel-to-panel locking plates are covered with curved top caps. All trim is painted metal to ensure color matching. The contractor will be responsible for the installation of the partitions, system, wiring and necessary components in accordance with industry standards. Floor diagram drawings will be provided at the site visit. It will be the responsibility of the winning contractor to ensure all measurements are accomplished prior to installation. If the walls do not fit once at the site, the contractor will take full responsibility to ensure the walls fit accordingly. 2.2 The following requirements are deemed necessary for the purchase and installation of the system: - Partitions will have as a minimum the following characteristics: -- sound damping -- locking full width doors -- demountable / reconfigurable -- raceway panel configurations -- fabrics complementary to the existing wall color (white) --- cherry wood laminates or other similar dark woods --- vented --- may have optional tackable surfaces, whiteboard surfaces, etc. -- Installed from floor to ceiling in a secure manner but not a permanent installation - Minimum requirement for power/network drop is for an allowance only (i.e one power and one network single-gang box per location as approximately indicated by the below diagram and requisite allowance to route appropriate wiring from the floor to the network/power box) -- See below diagram for approximate power/network drop locations. - Wall color scheme to follow existing walls in the area. - Walls need to be appropriate to an office environment. - Door hardware will accept Best Lock cores to conform with the established base lock and key plan (figure 8 style). - Installation to occur on or around 4 May 2009 2.3 See attached diagram for approximate location for wall installation. The attached drawing is not to any scale. Field measurements are required for wall positioning as well as height. The partitions will need to be located to ensure they do not conflict with ceiling diffusers (each room needs a supply and return air vent), lights, motion detectors, windows, or sprinkler heads. At the perimeter walls on the north side of the building, there is a light soffit, structural beam, and cross bracing that obstructs a smooth connection between the partition and the wall. The partition installation will need to address this irregularity. 2.4 Documentation. The contractor shall provide the operation and maintenance documentation for the partitions after completion of the project in both paper and searchable electronic format. Contractor will also provide As Installed drawings at the time of project completion. 2.5 Integration. The contractor shall perform all acceptance testing of the partitions to ensure operational capability in all areas. 2.6 Contractor personnel will require installation passes due to project being accomplished in a DOD environment. The contractor may provide required documentation to Camp Murray security in order to obtain base passes. 2.7 Period of Performance The project is required to be completed within 60 calendar days after contract award (this will include the manufacturing, delivery and installation). If the contractor cannot meet the required deadline, bid shall be considered non-responsive. 3.0 PROGRAM MANAGEMENT 3.1 Warranty. The contractor shall provide the required commercial warranty for a minimum of one year after installation of equipment.
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=f6c4758a290b92602f51c7e5f0c61ef6&tab=core&_cview=1)
- Place of Performance
- Address: 141 ARW/LGC Washington Air National guard Contracting Office, 2 South Olympia Avenue Fairchild AFB WA<br />
- Zip Code: 99011-9439<br />
- Zip Code: 99011-9439<br />
- Record
- SN01793443-W 20090417/090415222811-f6c4758a290b92602f51c7e5f0c61ef6 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |