Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 27, 2009 FBO #2678
SPECIAL NOTICE

59 -- Notice of Intent to Sole Source LI-6400XTR

Notice Date
3/25/2009
 
Notice Type
Special Notice
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Agriculture, Agricultural Research Service, Midwest Area Urbana, IL, 1101 West Peabody Drive, Room 180, Urbana, Illinois, 61801
 
ZIP Code
61801
 
Solicitation Number
AG-518P-P-09-AA75
 
Archive Date
4/23/2009
 
Point of Contact
Randa Plotner,, Phone: 217-244-3262
 
E-Mail Address
randa.plotner@ars.usda.gov
 
Small Business Set-Aside
Total Small Business
 
Description
Statement of Work: We need a gas exchange system that is identical to the existing LI-COR 6400 systems that are currently used in our research laboratories. We need system that will be used to investigate the responses of leaf photosynthesis, as measured with both gas exchange and chlorophyll fluorescence, to a range of environmental conditions. The use of this equipment will help us to determine the impact of various stress events, genetic modifications, environmental changes, or other effects on plant photosynthesis. The specifications are as follows: System: Type: Absolute, open path, non-dispersive infrared gas analyzer. Range: 0-3000 µmol mol-1. Bandwidth: 10 Hz. Signal Noise: Typically 0.3 µmol mol-1 peak-to-peak at 350 µmol mol-1 with 1 second signal averaging; 0.8 µmol mol -1 maximum. With 4 second signal averaging, signal noise is typically 0.2 µmol mol-1 peak-to-peak. Accuracy: Maximum deviation: ± 5 µmol mol-1 from 0 to 1500 µmol mol-1 ± 10 µmol mol-1 from 1500 to 3000 µmol mol-1. Sensor: Solid state. Minimal sensitivity to motion. Orientation Sensitivity: ± 1 µmol mol-1 at 350 µmol mol-1 from any orientation. H2O Analyzer Type: Absolute, open path, non-dispersive infrared gas analyzer. Range: 0-75 mmol mol-1, or 40°C dew point. Bandwidth: 10 Hz. Signal Noise: Typically 0.04 mmol mol-1 peak-to-peak at 20 mmol mol-1 with 1 second signal averaging; 0.06 mmol mol-1 maximum. With 4 second signal averaging, signal noise is typically 0.03 mmol mol-1 peak-to-peak. Accuracy: Maximum deviation: ± 1.0 mmol mol -1 from 0-75 mmol mol-1. Temperature Operating Temperature Range: 0°C to 50°C. Optical Housing Block and Air Temperature: Sensor Type: 3-wire thermistor. Range: -10 to 50°C. Accuracy: Maximum error < ± 0.5°C. Typical Error: < ± 0.25°C. Temperature Control: Leaf chamber can be heated or cooled ± 6°C from ambient. Control Range: 0 to 50.0°C. Set point Resolution: 0.2°C. Leaf Temperature Thermocouple: Type: E. Range: ± 50°C of reference. Reference: Optical housing block thermistor. Accuracy: ± 10% of T difference between sample and reference junctions with amplifier zeroed; typically < 0.2°C. Output RS-232: Hardwired DTE. Expansion Slot : Supports either Compact Flash or Ethernet card adapter. Compact Flash Card: Industrial Grade (included) Ethernet Card Adapter: Type 1 CF Ethernet card, 10/100 Mbps (included) Air Flow Flow rate: 0 to 700 µmol s-1 with 6400-01 CO2 injector and 150 to 1000 µmol s-1 without CO2 injector. Pressure Pressure Range: 65 to 110 kPa absolute. Accuracy: ± 0.1% of full scale. Resolution: 0.002 kPa. Signal Noise (peak-to-peak): 0.002 kPa typical. System Console Processor: 400MHz Intel XScale Memory: 128 MB RAM for operation; 64 MB flash memory for data storage. Display: Adjustable contrast, backlit, 8 line x 40 character (240 x 64 dot) LCD graphic display. Keyboard: Full ASCII keypad, sealed from dust and moisture with membrane overlay. Power Requirement: 10.5 to 15 VDC; 4A maximum (current draw dependent upon system operation). < 10A momentary peak. 6400-01 CO2 Injector CO2 Mixing Range: < 50 µmol mol-1 to > 2000 µmol mol-1. Operating Temperature Range: 0-50°C. CO2 Source Assembly: Type: 12g pure liquid CO2 cylinder. Lifetime: 8 hours after activation regardless of use. CO2 Tank Connector Block: Minimum Pressure: 1250 kPa (180 psig). Maximum Pressure: 1500 kPa (220 psig). Usage Rate: constant at ~10 sccm. Light Measurement PAR Internal and External Chamber Sensors: Range: 0 to > 3000 µmol mol-1. Resolution: < 1 µmol mol-1. Calibration Accuracy: ± 5% of reading, traceable to NIST. 6400-02B LED Light Source Output Range: 0 to 2000 µmol m-2 s-1 at 30°C. Minimum Fraction Blue: 5% (photon basis). Typical Fraction Blue: 100 µmol m-2 s-1, 13%, 1000 µmol m-2s-1, 10%, 2000 µmol m-2 s-1, 7%. Red Peak Wavelength: 665 nm ±10 nm at 25°C. Blue Peak Wavelength: 470 nm ±10 nm at 25°C. Power Consumption at 2000 µmol m-2 s-1: 8W. Operating Temperature Range: 0-50°C. Size: 5.2H x 5.6W x 7.3D cm (2.0 x 2.2 x 2.9 in.). Weight: 0.2 kg (0.44 lb.). 6400-40 Leaf Chamber Fluorometer Specifications Measuring (Modulated) Light: Red LEDs, 630 nm, software controlled intensity, software selectable modulation frequencies of 0.25, 1, 10, and 20 kHz Actinic Light: Blue and Red LEDs, 470 and 630 nm, respectively, independent software control of blue and red intensity, 0 to 100 µmol m-2 s -1 PAR for the blue LEDs, 0 to 3000 µmol m-2 s -1 PAR for the red LEDs Saturation Light: Blue and Red LEDs, 470 and 630 nm, respectively, software controlled intensity, 0 to 7000 µmol m-2 s -1 PAR Far-Red Light : Far-Red LED, 740 nm, software controlled intensity Fluorescence Signal Temperature Dependence: < 1% drift with 10 °C change in temperature User Interface: LI-6400/6400XT console and remote Windows® and Macintosh® interface F Data Output (Analog): ±5V analog output for external data acquisition Power Consumption:< 6W during saturation pulse Leaf Area: 2.0 cm2 This notice is a being published pursuant to our intent to purchase items using a total small business set-aside. Only Small Businesses should respond with proposals. This Notice is being published as an Intent to Sole Source under FAR 6.302-1, (ii) Supplies may be deemed to be available only from the original source in the case of a follow-on contract for the continued development or production of a major system or highly specialized equipment, including major components thereof, when it is likely that award to any other source would result in- (A) Substantial duplication of cost to the Government that is not expected to be recovered through competition; This Notice is being published as an Intent to Sole Source only and does not obligate the Government. Please direct any inquiries to the following. Interested parties are encouraged to send their proposals for equipment which meets or exceeds the above Statement of Work and Minimum Requirements Specification on their company letterhead along with any pertinent attachments, brochures or literature to: USDA/ARS, Randa Plotner, Purchasing Agent, 1101 W. Peabody Drive, 180 NSRL, Urbana, IL 61801, phone: 217-244-3262 Fax: 217-244-7703, e-mail address: randa.plotner@ars.usda.gov
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=b1bad64ae86eecd14ef330dece7d87a8&tab=core&_cview=1)
 
Place of Performance
Address: USDA/ARS, 193 ERML, 1201 W. Gregory Drive, Urbana, Illinois, 61801, United States
Zip Code: 61801
 
Record
SN01777407-W 20090327/090325215933-b1bad64ae86eecd14ef330dece7d87a8 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.