C -- Detailed Study and Assessment Report of Computer Center

Notice Date
2/12/2009
 
Notice Type
Sources Sought
 
NAICS
541330 — Engineering Services
 
Contracting Office
Department of Energy, Princeton Plasma Physics Laboratory (DOE Contractor), Princeton University, US Route 1 North at Sayre Drive, P.O. Box CN-17, Princeton, New Jersey, 08543
 
ZIP Code
08543
 
Solicitation Number
RFP09-037F
 
Archive Date
3/13/2009
 
Point of Contact
Larry L. Sutton,, Phone: (609)243-2441, Kevin D. Ranahan,, Phone: 609-243-2011
 
E-Mail Address
lsutton@pppl.gov, kranahan@pppl.gov
 
Small Business Set-Aside
N/A
 
Description
Princeton University Plasma Physics Laboratory (PPPL) a US Department of Energy Prime Contractor has a requirement for a detailed Study of its Computer Center's cooling system by an Assessment Team of individuals with extensive experience in computer data center evaluation and design. Interested qualified parties requested to submit Standard Form 330 Architect-Engineer Qualifications to the PPPL RFP 09-037F Coordinator L. Sutton at lsutton@pppl.gov by 2:00 P.M. Thursday 26 February 2009 for review and technical evaluation. The Computer Center (PPLCC) was established circa 1977 to support the computing requirements for both experimental and business aspects of PPPL. In recent years a significant quantity of high-density servers has replaced older technology servers. Existing computers are air-cooled via Computer Room Air Conditioner (CRAC) units forcing supply air through an under floor air plenum providing the computer racks bottom to top air cooling. These existing units have a rated nominal 80 ton total cooling capacity along with humidification and electric reheat capability. The Study shall include on-site inspection and measurements that include but are not limited to: Computer Room Floor Layout showing electrical and mechanical equipment in a AutoCAD ® or a CAD program that can be translated into AutoCAD ® format; an electrical single-line diagram (power protection and distribution infrastructure sizing and locations); a mechanical single-line diagram (computer room cooling room infrastructure sizing and locations); on-site thermal and electrical load assessments; Computational Fluid Dynamics (CFD) study with computer modeling; an assessment of existing PPLCC conditions listing both pro and cons; assessment of projected computational requirements and existing CRAC units for both condition and efficiency. Study also to include a number of conceptual "what if" recommendations with estimated dollar values.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=fd2667aaabae5133ae3cb23a591c72cb&tab=core&_cview=1)
 
Place of Performance
Address: Work to be performed at Subcontractor's facility. Visits to PPLCC at C-Site, James Forrestal Campus, US Route No. 1 north will be required., Plainsboro, New Jersey, 08536, United States
Zip Code: 08536
 
Record
SN01749751-W 20090214/090212220238-fd2667aaabae5133ae3cb23a591c72cb (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.