SOLICITATION NOTICE
66 -- Gas Detector: instrument must detect ortho-perflourodicyclohexane (oPDCH)
- Notice Date
- 2/12/2009
- Notice Type
- Presolicitation
- NAICS
- 335999
— All Other Miscellaneous Electrical Equipment and Component Manufacturing
- Contracting Office
- Department of Energy, Brookhaven National Laboratory (DOE Contractor), Brookhaven, PO Box 5000, Bldg. No. 355, Upton, New York, 11973
- ZIP Code
- 11973
- Solicitation Number
- 143301
- Response Due
- 2/20/2009
- Archive Date
- 3/7/2009
- Point of Contact
- Jeanmarie Volkmann,, Phone: 6313444929
- E-Mail Address
-
jvolkmann@bnl.gov
- Small Business Set-Aside
- N/A
- Description
- PLEASE SEE ATTACHED PDF FILES CONTAINING PRESOLICITATION NO. 143301 PLEASE DOWNLOAD THE FILES FROM THIS WEBSITE. ALL QUESTIONS, WHETHER TECHNICAL OR CONTRACTUAL, MUST BE SENT ELECTRONICALLY TO JEANMARIE VOLKMANN, JVOLKMANN@BNL.GOV. IF YOU WILL BE RESPONDING TO THIS SOLICITATION, YOU MUST SUBMIT AN EMAIL TO JVOLKMANN@BNL.GOV ACKNOWLEDGING YOUR PARTICIPATION IN THIS PRESOLICITATION. IF ANY QUESTIONS SHOULD ARISE, YOU WILL BE NOTIFIED ELECTRONICALLY. The instrument must detect ortho-perflourodicyclohexane (oPDCH) in soil gas (humid air with up to 90% methane) using cavity enhanced laser absorption spectroscopy that accurately and rapidly measures the concentrations of oPDCH in real time. It must be based on a commercially available platform, simple to operate, portable (less than ¼ cubic meter, 24VDC or household current and less than 75 lbs), and short response time capable of directly measuring absorption spectra of oPDCH in ambient air in a measurement time of less than 30 seconds with a minimum sensitivity of <10 ppbv and a preferred sensitivity of at least 1 ppbv. The platform must contain an external cavity Infrared laser. Manufacturer must provide a calibration curve, software specific for oPDCH and an operations manual. Detection limits must be demonstrated at BNL before delivery/acceptance of the final turn key system. Offerors must provide documentation of no less than three (3) years of proven field deployment of at least 25 units per year.
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=4e255103b0109ff8edcb041dd1f3efd6&tab=core&_cview=1)
- Place of Performance
- Address: Brookhaven National Laboratory, Upton, New York, 11973, United States
- Zip Code: 11973
- Zip Code: 11973
- Record
- SN01749571-W 20090214/090212215844-4e255103b0109ff8edcb041dd1f3efd6 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |