Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 14, 2009 FBO #2637
SOLICITATION NOTICE

41 -- TWO AIR HANDLER UNITS FOR TCU

Notice Date
2/12/2009
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
423730 — Warm Air Heating and Air-Conditioning Equipment and Supplies Merchant Wholesalers
 
Contracting Office
Department of Veterans Affairs, VA North Texas Health Care System, Department of Veterans Affairs No. Texas Health Care System, Department of Veterans Affairs;North Texas Veterans Health Care Center;4500 S. Lancaster Road;Dallas TX 75216
 
ZIP Code
75216
 
Solicitation Number
VA-257-09-RQ-0117
 
Response Due
2/23/2009
 
Archive Date
3/25/2009
 
Point of Contact
Elton SticherContract Specialist<br />
 
Small Business Set-Aside
Total Small Business
 
Description
COMBINED SYNOPSIS / SOLICITATION McQuay Air Handling Units, Models AHU 16500 and AHU 17500 or Equal (1 Each). Dallas VA Medical Center, Dallas TX (1)This is a combined synopsis/solicitation for a commercial item prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. (2)This solicitation is issued as a request for quote (RFQ). Submit written quotes (oral quotes will not be accepted) on RFQ reference number VA-257-09-RQ-0117. (3)This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-27. (4)This procurement is being issued as a 100% small business set-aside. The North American Industry Classification System (NAICS) code is 423730 with a small business size standard of 500 employees. (5)Description as follows: McQuay Air Handling Units, Models AHU 16500 and AHU 17500 or Equal (1 Each). (All "or equal" submittals must come with technical specifications to be considered responsive.) See Information Below for Salient Characteristics. (6)Delivery shall be no later than 10 weeks after receipt of order, FOB Destination, at the following address: VA Medical Center 4500 South Lancaster Road Building # 44 Dallas, TX 75216 The Dallas VA is requesting bids for two Air Handler Units. Both new units must fit on existing pad area. Total dimensions should be approx. 104" wide x 168" long, no more than 70"tall. New unit will be horizontal discharge, and return air will drop vertically to top of unit. Facing unit; discharge on left, intake on right, coil connection on rear, doors on front. A/C EQUIPMENT: Salient Characteristics. 1.Air Handler unit #1; Quantity One Each $ _____________ 17500CFM @ 3.4" total static press., External static pressure- 2.0" Shall have; sections including OA/RA mixing box, filters, hot water preheat, chill water coil, and blower. Double wall construction, built of 18 gauge exterior, and 22 gauge interior galvanived metal 2" R13 or better foam insulation. Stainless steel double sloped drain pan. Access doors at service side of blower, filters, and between coils. Chill water coil needs to be a 15deg.coil, total cap. Of approx. 695338 btu/h. Chill water coil have stainless steel casing. Preheat coil is hot water, approx. 555038 btu/h Blower section will have a premium effiency 20hp motor. 208v 3ph. All sections will be mounted on a 6" base rail. Unit to be shipped in sections to accommodate installation. Marine lighting to be mounted in blower section and access sections. 2.Air Handler Unit #2; Quantity One Each $______________ 16500 cfm @ 3.4" TSP, External static pressure 2.0" Unit to be built in sections to include Blower, Chill water coil, preheat coil, filter, and RA/ OA mixing box w/dampers. Double wall construction of 18 gauge exterior and 22 gauge interior galvanized metal. 2" R13 or better foam insulation. Stainless steel double sloped drain pan. Access doors at service side of blower, filters, and between coils. Chill water coil needs to be a 15deg. Coil, total cap. approx 652627 btu/h. Chill water coils will have stainless steel casing. Preheat coil is hot water approx. 543561 btu/h Blower will have a 208v, 3ph, 20hp Premium efficiency motor.Section will be mounted on 6" base rail. Sections shipped separate to accommodate installation. Blower and access sections to have marine light fixture. Technical Questions, please call Robert Inman at 214-857-1026. Shipping will be FOB Destination. Descriptive literature must be included with each bid. Brand name or equal to McQuay.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=f2589bc7e2ae2ee86fa5de05a7edb227&tab=core&_cview=1)
 
Place of Performance
Address: VA Medical Center;4500 South Lancaster Road;Dallas, TX<br />
Zip Code: 75216<br />
 
Record
SN01749546-W 20090214/090212215819-f2589bc7e2ae2ee86fa5de05a7edb227 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.