Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF OCTOBER 12, 2008 FBO #2512
SOURCES SOUGHT

R -- Rehabilitation and Painting of Tainter GatesFort Gibson Lake Dam, Wagner County, OK and Kaw Lake Dam, Kay County, OK

Notice Date
10/10/2008
 
Notice Type
Sources Sought
 
NAICS
562910 — Remediation Services
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, U.S. Army Engineer District, Tulsa, US Army Engineer District, Tulsa, ATTN: CESWT-CT, 1645 South 101st East Avenue, Tulsa, OK 74128-4609
 
ZIP Code
74128-4609
 
Solicitation Number
W912BV-TBD-FTGIBSON
 
Response Due
10/21/2008
 
Archive Date
12/20/2008
 
Point of Contact
Robert Y. Tipton, 918-669-7272<br />
 
Small Business Set-Aside
N/A
 
Description
SOURCES SOUGHT Rehabilitation and Painting of Tainter Gates Fort Gibson Lake Dam, Wagner County, OK and Kaw Lake Dam, Kay County, OK. The purpose of this synopsis is to conduct market research on potential sources for a future acquisition of Structural Rehabilitation and Painting services at Fort Gibson Lake Dam and Kaw Lake Dam, Oklahoma. This is not a request for competitive proposals or quotations. It is anticipated that the following services will be required: Removing debris, laminated rust, pack rust, unclogging drain holes, cleaning out trunnion yokes by removing the Plexiglas cover and clearing out dirt and moss, and blasting to SSPC SP5 (white metal) the downstream and upstream side of each tainter gate. Each gate shall be painted with system no. 5-E-Z. Cleaning and painting shall be so programmed that dust or other contaminants from the cleaning process do not fall on wet, newly painted surfaces. Structural repairs shall be made to the gates to fix corrosion damage. At Ft. Gibson - replacing hoist platform anchor bolts, nuts, and washers, treating pack rust on hoist platform beams with a rust inhibitor to neutralize the rust and to reseal the joint along the edge of the beam. At Ft. Gibson - applying a protective finish coating to the concrete at the pier landings starting from where the tie back beams first jut into the concrete extending along the access hallway to the ladder. At Kaw Lake - replace existing side seal assemblies. Clean all existing Government property including the gates, weirs, and bridge of all blast media and debris resulting from the Contractors construction activities. Potential sources must submit a capability statement of no more than 4 pages in length, which addresses the following key areas: (1) TECHNICAL - Potential sources must submit a list of recent projects that demonstrate their knowledge and past experience relating to all of the varying types of work described above, particularly in the areas of tainter gate painting, structural reapair of hoist anchor components, safety, and quality control. Individual task orders under IDIQ contracts should be listed as separate projects. Submit only current and past project and client information that is no more than 4 years previous and include a brief description, identify the capacity the firm worked in on the project (prime or subcontractor), the contract type (list by task order if IDIQ), contract or task order value, dollar value of work subcontracted, percent complete, if complete date completed, name and title of customer POC and current phone number. (2) BUSINESS SIZE - Potential sources shall identify if they are a large, small, SDB/8a, women-owned or veteran / disabled-veteran owned small business. If the firm is a small business, the response to this synopsis must include how the firm it will meet the Federal Acquisition Regulations (FAR) requirements for limitations in subcontracting for the proposed solicitation (or completed contracts of a similar nature and size) that states &at least 15% of the cost of contract performance incurred for personnel shall be expended for employees of the concern. All interested parties may respond or submit statements of qualifications. This is not a request for competitive proposals or quotations. A determination by the Government not to compete this proposed contract is within the discretion of the Government. All responses are due to US Army Engineering District, Tulsa, District Office, Attention: Susie Mall, 1645 S 101 E Ave, Tulsa, OK 74128, not later than 4:00pm CST on October 21, 2008. This action will be conducted under FSC Code F108, SIC Code 8744, NAICS Code 562910. The size standard is 500 employees. Please direct all questions to US Army Engineer District, Tulsa, Attention: Ms. Susie Mall, Contract Specialist, phone (918) 669-7273, fax: (918) 669-7495, email address: Susie.Mall@usace.army.mil.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=d8bf6641d7ec883b850f68abe190364f&tab=core&_cview=1)
 
Place of Performance
Address: US Army Engineer District, Tulsa ATTN: CESWT-CT, 1645 South 101st East Avenue Tulsa OK<br />
Zip Code: 74128-4609<br />
 
Record
SN01691198-W 20081012/081010215158-d8bf6641d7ec883b850f68abe190364f (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.