Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 24, 2008 FBO #2341
SOLICITATION NOTICE

66 -- ENVIRONMENTAL CHAMBER

Notice Date
4/22/2008
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Labor, Mine Safety and Health Administration, Acquisition Management Branch (WV), 1301 Airport Road, Beaver, West Virginia, 25813-9426
 
ZIP Code
25813-9426
 
Solicitation Number
464-08MR-1560
 
Point of Contact
ALEISHA T MOORE, Phone: 304-256-3215
 
E-Mail Address
MOORE.ALEISHA@DOL.GOV
 
Small Business Set-Aside
Total Small Business
 
Description
MSHA IS SEEKING QUOTES FOR THE FOLLOWING: QTY. 1 – ESX-4CA PLATINOUS TEMPERATURE & HUMIDITY CHAMBER QTY. 1 – DRY AIR PURGE QTY. 1 – WATER FILTER SYSTEM FOR HUMIDITY SUPPLY QTY. 1 – HUMIDITY WATER SUPPLY TANK QTY. 1 – INNER GLASS DOOR WITH FOUR OPERATION PORTS (NO OUTER WINDOW/LIGHT) QTY. 1 – CABLE PORT, 2” DIAMETER WITH TWO FLEXIBLE SILICONE PLUGS Below are specifications for Environmental Chamber: 1. Temperature Range: -73C to +150C 2. Humidity Range: 10 to 90% 3. Load: The test specimen dimensions vary; the chamber is used for approval testing of gas detectors used in underground mining. The largest system has included components (non-portable) that weigh up to 40lbs; heat output of specimens is not specified, but all external surfaces of tested equipment is routinely carried by, or manipulated by hand (surfaces certainly less than 40C). 4. Heating Rate: Rapid changes in temperature not needed, either up or down. Test procedures allows 1 hour between tests, which are conducted at 5 F intervals. In other words, we allow the samples to soak for 1 hour after the air temperature has stabilized. 5. Cooling Rate: See above 6. Power: 220VAC/60Hz [Single or 3-Phase OK] 7. Interior size: 27 to 32 cubic feet 8. Exterior size: Size limitations: The door to get into the lab is 93” by 84”. The lab height is ~12 feet. 9. Facilities: Water Reservoir for humidity supply (plumbed line available, but reservoir desired) 10. Test standards: Most tests are custom from Title 30 CFR Parts 22 and 27. See http://www.msha.gov/30cfr/22.0.htm and http://www.msha.gov/30cfr/27.0.htm. The standard test procedures can be found at http://www.msha.gov/TECHSUPP/ACC/StandardTestProcs/ASTP2203.pdf, http://www.msha.gov/TECHSUPP/ACC/StandardTestProcs/ASTP2228.pdf, http://www.msha.gov/TECHSUPP/ACC/StandardTestProcs/ASTP2229.pdf. The chamber will be used for custom tests of equipment recovered from mine explosions; low humidity (approximately 10%RH) may rarely be desirable. 11. Controller: Programmable 12. Window: Observation Window (or equivalent) 13. Communication: Serial (RS-232, RS485, USB, etc.) OR parallel (GPIB), OR analog outputs of temperature and humidity 13. # of Access Ports One 2” Port for electrical cords and gas tubing 14. Gloves port: One set (or equivalent) 15. Shelves: One set (see Load above) 16. Interior light: One (if necessary for visibility) PLEASE PROVIDE QUESTIONS VIA E-MAIL BY 04/28. NO PHONE CALLS WILL BE ACCEPTED. ITEM NUMBER PROVIDED BY ESPEC NORTH AMERICA. PLEASE QUOTE BRAND NAME OR EQUIVALENT.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=56275ab8c3d0eb97c48d6280bc1a397b&tab=core&_cview=1)
 
Place of Performance
Address: DEPT. OF LABOR, MINE SAFETY & HEALTH ADMINISTRATION, RR 1, BOX 251, INDUSTRIAL PARK ROAD, TRIADELPHIA, West Virginia, 26059, United States
Zip Code: 26059
 
Record
SN01558859-W 20080424/080422221049-56275ab8c3d0eb97c48d6280bc1a397b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.