MODIFICATION
36 -- TEST CHAMBERS
- Notice Date
- 12/26/2007
- Notice Type
- Modification
- NAICS
- 333999
— All Other Miscellaneous General Purpose Machinery Manufacturing
- Contracting Office
- ACA, Aberdeen Proving Ground, Directorate of Contracting, 4118 Susquehanna Avenue, Aberdeen Proving Ground, MD 21005-3013
- ZIP Code
- 21005-3013
- Solicitation Number
- W91ZLK-08-T-0083
- Response Due
- 12/27/2007
- Archive Date
- 2/25/2008
- Point of Contact
- Susan Sowa, 410-278-0771
- E-Mail Address
-
ACA, Aberdeen Proving Ground
(susan.sowa@us.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- AMENDMENT 0004 IS ISSUED TO PROVIDE ANSWERS TO ADDITIONAL QUESTIONS. THE CLOSING DATE OF THE SOLICITATION REMAINS UNCHANGED AT DECEMBER 27, 2007, 2:00 PM EASTERN STANDARD TIME. Quotations must be signed, dated, and received by the closing date and ti me, via fax at 410-306-3726 or email at susan.sowa@us.army.mil at the US Army Contracting Agency, Directorate of Contracting, Attention: SFCA-NR-APC-T, 4118 Susquehanna Avenue, Aberdeen Proving Ground, MD 21005-3013. For questions concerning this Request for Quotations contact Susan Sowa Contracting Specialist @ (410) 278-0771 or email susan.sowa@us.army.mil . Please submit your quotations to Ms. Sowa via email to: susan.sowa@us.army.mil or Fax 410-306-3726. Note the following change in the W91ZLK-08-T- 0083 Specifications: 1 each Sussman 3 kW steam generator based humidity system with a solid state relative humidity transmitter/sensor. Modified to read: 1 each 3 kW electric steam boiler based humidity system with a solid state relative humidity tran smitter/sensor. The boiler must be capable of processing Deionized water. Provide boiler feed water pump as required. QUESTIONS AND ANSWERS ARE AS FOLLOWS CLIN 0001 - QUESTION 13: I see a requirement for intake air and an exhaust blower. Will there be solvent inside the chamber? How much exhaust/intake air is required? The 3kw steam generator that is specified will not be able to produce enough steam to match the humidity rate specified if we are intaking and exhausting very much air. Answer: The air i nside the chamber is 100% recirculated. The air being exhausted is inside the machinery compartment (storage area for water tank, refrigeration, steam generator, etc). We need enough air changes to maintain good operating conditions for the mechanical equi pment in this space. The fresh air intake system that the specs reference is for the dehumidifier. There will be no solvents in the chamber. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (26-DEC-2007); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link to FedBizOpps document.
(http://www.fbo.gov/spg/USA/DABJ/DABJ05/W91ZLK-08-T-0083/listing.html)
- Place of Performance
- Address: ACA, Aberdeen Proving Ground Directorate of Contracting, 4118 Susquehanna Avenue Aberdeen Proving Ground MD
- Zip Code: 21005-3013
- Country: US
- Zip Code: 21005-3013
- Record
- SN01476365-F 20071228/071226223910 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |