SOURCES SOUGHT
J -- Coleman National Fish Hatchery Water Intake Rehabilitation
- Notice Date
- 11/15/2007
- Notice Type
- Sources Sought
- Contracting Office
- Bureau of Reclamation - Mid-Pacific Regional Office 2800 Cottage Way, Room E-1807 Federal Building Sacramento CA 95825
- ZIP Code
- 95825
- Solicitation Number
- 08SP200038
- Response Due
- 11/29/2007
- Archive Date
- 11/14/2008
- Point of Contact
- Bettye Lou Mahoney Contract Specialist 9169785570 bmahoney@mp.usbr.gov;
- E-Mail Address
-
Email your questions to Point of Contact above, or if none listed, contact the IDEAS EC HELP DESK for assistance
(EC_helpdesk@NBC.GOV)
- Small Business Set-Aside
- Total Small Business
- Description
- The Bureau of Reclamation is issuing this announcement to identify potential certified HUBZone and/or 8(a) Small Business concerns who would be interested in performing work for the Coleman National Fish Hatchery Water Intake Rehabilitation project located approximately 20 miles southeast of Redding, California on Battle Creek in Shasta and Tehama Counties. The principal components of work include the following: Schedule A: A. Demolishing existing reinforced concrete water Intake No. 3 structure. B. Constructing a service yard area and access road with compacted fill. C. Constructing a new reinforced concrete water intake structure with traveling fish screens and stop logs. D. Constructing a new control building using reinforced concrete unit masonry assemblies. E. Furnishing and installing an engine generator set with automatic transfer switch in the Control Building. F. Furnishing electrical power and controls for the entire facility. Optional Schedule 1: A. Expanding existing Intake No. 1 structure by constructing a reinforced cast in place concrete bay adjacent to the existing structure. B. Constructing a new 2,000 foot long 36 inch diameter pipeline from the expanded Intake No. 1 structure to the new Intake No. 3 structure. Pipeline may be PVC pressure pipe, reinforced concrete pressure pipe, steel line pipe, HDPE pressure pipe, reinforced plastic mortar pipe, or pretensioned concrete cylinder pipe. C. Furnishing trashrack and valves for the expanded intake structure. Optional Schedule 2: A. Demolishing the existing Intake No. 1 weir structure. B. Constructing a new Intake No. 1 weir structure using cast in place reinforced concrete. C. Furnishing and installing weir logs and embedded guides. The applicable North American Industry Classification System (NAICS) Code is 237990 and the related small business size standard in dollars is $31 Million. The estimated cost of this project is between $5,000,000.00 and $10,000,000.00. This procurement is being considered for 100 percent set-aside for HUBZone and/or 8(a) small business concerns; however, all interested parties are requested to respond. If adequate interest or sufficient supporting documentation is not received from HUBZone and/or 8(a) concerns, the solicitation may be issued as a small business set-aside or unrestricted basis without further notice or may be canceled. This procurement will require 100% performance and payment bonds. Interested parties should include the following information in their response: (a) Business name, address, cage code, size classification based on NAICS size standard, socioeconomic classification (i.e. HUBZone and/or 8(a)), and a point of contact. (b) A copy of the certificate issued by the SBA of your qualifications as a HUBZone and/or 8(a) small business concern. (c) A positive statement of your intention to submit an offer for this solicitation as a prime contractor. (d) Evidence of your Bonding capacity and (e) Evidence of your experience performing work similar in type and scope to include: contract numbers, project titles, dollar amounts and points of contacts with telephone numbers. In addition, include attachments cataloging the company's equipment assets, personnel resources and financial resources that demonstrate company responsibility and capability to perform required work. This notice is not a request for proposal and the information presented in this announcement will not obligate the Bureau of Reclamation in any manner. Central Contractor Registration (CCR) and Annual Representations and Certifications, as required by FAR 4.1102, apply to this procurement. Prospective contractors must be registered prior to award. Lack of registration in the CCR database will make an offeror ineligible for award. Information on CCR registration can be obtained via the Internet at http://www.ccr.gov. Information on annual Representations and Certifications can be obtained via the Internet at http://orca.bpn.gov. All interested parties are encouraged to respond to this notice, by e-mail to bmahoney@mp.usbr.gov not later than the close of business on November 29, 2007.
- Web Link
-
Please click here to view more details.
(http://ideasec.nbc.gov/j2ee/announcementdetail.jsp?serverId=BR142520&objId=222553)
- Place of Performance
- Address: Coleman National Fish Hatchery
- Zip Code: 96007
- Country: USA
- Zip Code: 96007
- Record
- SN01453235-W 20071117/071115225100 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)