SOLICITATION NOTICE
52 -- Remote Optical Particle Counter for the Pentagon Force Protection Agency Chemical, Biological, Radiological, and Nuclear Directorate
- Notice Date
- 8/16/2007
- Notice Type
- Solicitation Notice
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of the Navy, Naval Air Systems Command, Naval Air Warfare Center Training Systems Division, 12350 Research Parkway Code 253, Orlando, FL, 32826-3224, UNITED STATES
- ZIP Code
- 00000
- Solicitation Number
- Reference-Number-08152007CSGPFPA
- Response Due
- 8/30/2007
- Archive Date
- 9/14/2007
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. *****Description: The Pentagon Force Protection Agency (PFPA) Chemical, Biological, Radiological, and Nuclear (CBRN) Directorate requires remote optical particle counters. The fully integrated remote particle counter-based sensor shall meet the following requirements: 1) Counts dust particulate and provides these counts in at least two channels with adjustable size cut-offs: a. One channel shall provide particle counts of particles that are smaller than one micrometer; and b. An additional channel(s) shall provide particle counts for particles that are between 1 -10 micrometer. 2) Sends an update of particle counts at a minimum of every six seconds. 3) Sends status, health, and particle count information using a standard LAN IP connection. All particle counter information shall be transmitted on one IP address, and this address can be configured onsite if required. 4) The particle counters, and supporting equipment shall be placed in a shelter that is no larger than 15 inches x 5 inches x 12 inches. The shelter must be mountable on a 24 inch x 24 inch metal ceiling tile. The shelter design will ensure that sampling ports are situated on the bottom face. Sample tubes will extend through the ceiling tile at least 2 inches. The shelter shall not extend higher than 12 inches above the ceiling tile. 5) Shall operate with 24 VDC at maximum of 50 VA. 6) The system sound power level shall be less than 50 dB when measured one meter distant from the instrument. 7) Can withstand a drop of two inches with no degradation of performance. 8) When packaged for shipping, the system should survive typical shipping conditions, including vibrations in a shipping or delivery vehicle without degradation of performance. *****In addition, the following requirements are desirable, but not mandatory: 1) Lower the cost of logistics and maintenance by increased reliability and ease of maintainability when operated in a HEPA-filtered environment. 2) Do not require preventive maintenance more often than biannually (twice per year) 3) Show additional specificity of particle count information such as distribution of particles in other sizes, multiple bins, etc. 4) Do not involve expensive, frequent recalibration 5) Can be easily installed and removed from the 24 inch x 24 inch metal ceiling plate as may be required for maintenance. 6) Provides a warranty of at least one year for major repairs and replacement. 7) Adequate free space in the housing to add additional capabilities as required. *****CLIN 0001: Remote Optical Particle Counters Quantity: 100 Unit of Issue: Lot *****FOB: Destination. *****Delivery: January 11, 2008 *****Ship To: PFPA-CBRN ATTN: Robert Fitzgerald, room 1E533 9000 Defense Pentagon Washington, DC 20301-9000***** Applicable provisions/clauses: 52.212-1, Instructions to Offerors ?Commercial (Provision); 52.212-4, Contract terms and Conditions- Commercial Items (Provision); 52.243-1, Changes-Fixed Price; 52.247-34 FOB Destination; 252.204-7004 Alt. Central Contractor Registration; 52.212-5 (Dev) Contract Terms and Conditions Required to Implement Statutes or Executive Orders- Commercial Items; 252.232-7003, Electronic Submission of Payment Request; 52.212-3, Offeror Representations and Certifications-Commercial Items (Provision)***** The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers: Technical and Price.***** The FFP Proposal shall include a breakdown of the unit price and transportation cost along with any discounts being applied. If the offeror has catalog pricing or historical pricing information to support the FFP proposed this information shall also be provided.***** The Technical Proposal shall include a description of the proposed item and how it meets the solicited requirement. All applicable product literature, technical features, and warranty information shall also be provided.***** Offers shall submit a FFP for the requirement described above by 5:00 PM EST on 30 August 2007 to scott.syring@us.army.mil.
- Place of Performance
- Address: PFPA-CBRN, 9000 Defense Pentagon, Washington, DC 20301-9000
- Zip Code: 20301-9000
- Country: UNITED STATES
- Zip Code: 20301-9000
- Record
- SN01375362-W 20070818/070816222351 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |