Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 28, 2007 FBO #2070
SOLICITATION NOTICE

59 -- Engine and Transmission Testing Dynometer and Sound Control Room

Notice Date
7/26/2007
 
Notice Type
Solicitation Notice
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
USPFO for Louisiana, 495 3rd Street, Camp Beauregard, Pineville, LA 71360
 
ZIP Code
71360
 
Solicitation Number
W912NR07T0009
 
Response Due
8/16/2007
 
Archive Date
10/15/2007
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Al correspondence shall reference number Request for Quote W912NR-07-T-0009. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquis ition Circular 2005-17. The following clauses are incorporated by reference: 52.203-6 (Alt I), Restrictions on Subcontractor Sales to the Government; 52.204-4, Printed or Copied Double-Sided on Recycled Paper; 52.219-6, Notice of Total Small Business Set -aside; 52.219-8, Utilization of Small Business Concerns; 52.222-3, Convict Labor; 52.222-19, Child Labor-Cooperation with Authorities and Remedies; 52.222-21, Prohibition of Segregated Facilities; 52.222-26, Equal Opportunity; 52.222-25, Affirmative Actio n; 52.222-22, Previous Contracts and Compliance Reports; 52.222-35, Affirmative Action for Disabled Veterans and Veterans of the Vietnam Era; 52.222-39, Notification of Employee Rights Concerning Payment of Union Dues or Fees; 52.225-13, Restrictions on Ce rtain Foreign Purchases; 52.232-33, Payment by Electronic Funds Transfer  Central Contractor Registration (31 U.S.C. 3332); 52.232-36, Payment by Third Party; 52.222-42, Statement of Equivalent Rates for Federal Hires; 52.222-43, Fair Labor Standards Act and Service Contract Act-Price Adjustment. The Following clauses and provisions are also incorporated by reference: 52.232-18, Availability of Funds; 52.252-1, Provisions Incorporated by Reference; 52.252-2, Clauses Incorporated by Reference. The followi ng clauses and provisions within 252.212-7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items (Deviation) are applicable; 52.203-3, Gratuities; 252.225-7012, Preferenc e for Certain Domestic Commodities; 252.243-7002, Request for Equitable Adjustment; 252.247-7023, Transportation of Supplies by Sea. Solicitation Provisions may be accessed in full text at http://farsite.hill.af.mil. This procurement is unrestricted. Th e North American Industry Classification System codes for this procurement are 332322, 334519, and 336350 The Louisiana Army National Guard intends to issue a contract for the following requirement: CLIN 1: Engine test stand 750 hp water brake dyno, TK style adapter kit with 18 and 24 inch adapter plates, 1810 drive shaft with guard and flange, automatic control for inlet water brake absorbers, automatic throttle controller panel, 24vdc throttle actu ator power supply with throttle actuator, cable assembly to actuator, NGE analog control kit, temp sensor expansion kit, pressure sensor expansion kit, pressure hose kit, temp/humidity kit, temp/humidity probe, mag tach pickup, diesel relay box with 12/24 select 12v ECM power, glow plug power, starter, control output capability, engine cart with adapters for LDS-465-1, NTC 400, NTC 250, GM 6.2, 6.5, Detroit 8V92, Detroit 60 Series, Caterpillar 3126, torsional coupling, pressure regulator, pneumatic engine s tarter kit, hose interconnect kitfor engines up to 1,250 hp , 1000 hp in cell cooling tower, intercooler charge cooler up to 1000 hp, pro calibration kit, ups, cables, water recirculation system, freight, installation, training, all software, electronic en gine module interfaces to include caterpillar HEUI fuel systems, and Detroit DDEC. System must be upgradeable for future hardware and software configurations. CLIN 2: Transmission test stand electric drive eddy-current tester, 150 hp motor, 0-4000 rpm, 600 ft-lb input torque, 1350 ft-lb load torque, auto indexing, mounting kits for Allison MD3070PT, Allison AT, MT, & HT with auto indexing, GM 4L80E with quick connect cooler lines and auto indexing, GM 350/4 00 THM (3L80) with quick connect, remote control cables, and auto indexing, CAT 7155, Allison control console for military (World Transmission Controls) and ATEC systems in conjunction with standard hydraulic control console for close ratio series. Contro l console and data acquisition system for full manual control without computer and semi auto for testing with computer, freight, installation, training, all software, and all hardware. CLIN 3: Materials and installation costs to construct a 3 wall sound control room with an existing dyno cell. The objective is to design a control room to reduce the noise level inside the room by approximately 40 dBa. The outside dimensions of the cont rol room are 12 W x 20 L x 8 4 H (8 0 inside). Wall panels need at least an acoustical rating of STC 50. The solid outer and inner skins and are filled with sound damping acoustical fill material. Roof or ceiling panels will be at least an acousti cal rating STC 42. The solid outer skin and a perforated inner skin and are filled with sound dampening acoustic fill material. Two acoustic doors one on each 20 wall side of the test cell is required. The acoustic doors must have at least a rating of STC 45. The doors shall be equipped with double magnetic seals on the head and jambs, cam-lift hinges and a compression seal on the bottom of the door, and push/pull hardware is required. Three windows required: One on the 12 wide wall at the end of the control room and one on each side of the 20 walls. The window on the 12 wall and the window opposite the transmission dyno shall have at least a STC rating of 44. These windows shall be double glazed with ? tempered safety glass set in vibration res istant rubber gaskets. Another window opposite the engine dyno shall be ballistic rated window glazed with 1 3/16 bullet resistant glass on one side and ? tempered safety glass on the other side. The roof shall be designed to support two 250 lbs person s walking on it but not designed for storage. Data Acquisition and control system shall be with WYNDYN or compatible software compatible with both test stands. Sound control room (CLIN 3) capable of housing both test stands and control equipment. Include installation and freight as a separate expenses. Scope of work must be completed no later than 20 September 2007. Quotes shall be submitted via email not later than 16 August 2007, 10:00 a.m. CST to the attention of MAJ Jason Meyers, Jason.meyers @us.army.mil or COL Patti Woods, patti.woods@us.army.mil. Award will be based on best price, technically acceptable. Quotes/offers received after the specified due date and time will not be considered for award contract the above with any questions you m ay have.
 
Place of Performance
Address: LA Natil Guard, CSMS, SFC Scott Brouillette & SSG James Price, BLDG 6050 119 Wesrt Road Pineville LA
Zip Code: 71360
Country: US
 
Record
SN01353468-W 20070728/070726222114 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.