SOLICITATION NOTICE
65 -- ULTRASOUND SCANNING SYSTEM
- Notice Date
- 7/13/2007
- Notice Type
- Solicitation Notice
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- European Regional Contracting Office, ATTN:MCAA E, Building 3705, Landstuhl, Germany APO, AE 09180
- ZIP Code
- 09180
- Solicitation Number
- W9114F07T0156
- Response Due
- 7/25/2007
- Archive Date
- 9/23/2007
- Small Business Set-Aside
- N/A
- Description
- (i) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; propos als are being requested and a written solicitation will not be issued. (ii) Solicitation number: W9114F-05-T-0156 issued as a request for quotation (RFQ). (iii) Solicitation document and incorporated provisions and clauses are those in effect through Fed eral Acquisition Circular 2005-07. (iv) Not a set-aside. North American Industry Classification System (NAICS) code for this solicitation is 339112 (v) The Europe Regional Contracting Office has a requirement to purchase the following items: Descripti on of requirements for the items to be acquired: CLIN 0001 ULTRASOUND SCANNING MACHINE. VIVID I BT 04 SYSTEM. MIMIATURIZED ULTRA PORTABLE ULTRASOUND SYSTEM BASED ON THE TRUSCAN ARCHITECUTRE COMMOM TO ALL GE ULTRASOUND SYSTEMS, FEATURING A POWERFUL PC PLATFORM, RAW DATA/DICOM STORAGE WITH UNIQUE POST-PROCESSING CAPABILITIES, RECORD ARCHIVING AND MANAGEMENT, ON-BOARD HIGH CAPACITY HARD DISK STORAGE,AND THE SAME SOFTWARE PLATFORM, IMAGE QUALITY AND PREMIUM PERFORMANCE FOUND IN ITS LEADERSHIP SYSTEMS, A15 INCH HIGH-QUALITY LCD MONITOR PROVIDES WIDE -ANGLE VISIBILITY WITH PROGRAMMABLE ADJUSTMENTS FOR OPTIMAL IMAGE QUALITY UNDER A VARIETY OF AMBIENT LIGHT CONDITIONS. A RECHARGEABLE BATTERY PROVIDES ABOUT 1.0 HOUR OF FULL SCAN OPERATION. THE STANDARD CONFIGURATION INCLUDES SCANNING BATTERY, DVD/CD-RW, E CG MODULE, ECHONET CONNECTIVITY, ARCHIVING, MULTIPLE FOCI CONTROL, AUTOMATIC TISSUE OPTIMIZATION, LIVE ANATOMICAL M MODE, DICOM MEDIA CREATOR EXCEL FILE OUTPUT AND A GOPAC PORTABLE CASE. THE VIVID I INCLUDES 2 DAYS ON-SITEAPPLICATIONS TRAINING. 220 V, 50 HZ PN/CN: H45021A MFR: GE MEDICAL SYSTEMS CLIN 0002 CARDIAC APPLICATION MODULE, PN/CN: H45021AC CLIN 0003 7S - RS PHASED ARRAY TRANSDUCER. WIDE-BAND MULTI-FREQUENCY TRANSDUCER WITH BANDWIDTH BETWEEN 3.3 AND 7.0 MHZ. APPLICATIONS INCLUDE: CARDIAC, PEDIATRIC HEART, CORONARY, NEONATAL HEAD, OBDOMINAL, AND OBSTETRICS. PN/CN: H4000PE CLIN 0004 10S - RS PHASED ARRAY TRANSDUCER. WIDE-BAND MULTI-FREQUENCY TRANSDUCER WITH BANDWIDTH BETWEEN 4.0 AND 10.0 MHZ. APPLICATIONS INCLUDE: CARDIAC, PEDIATRIC HEART, CORONARY AND NEONATAL HEAD. PN/CN: H4000PF CLIN 0005 DICOM NETWORK CONNECTIVITY. DICOM NETWORK CONNECTIVITY PROVIDES DICOM OUTPUT TO A DICOM SERVER AND DICOM MEDIA INTERCHANGE. INCLUDES VERIFICATION AE, IMAGE EXPORT AE ( NETWORK STORAGE), MODALITY WORKLIST AE, MEDIA CREATOR, STORAGE COMMITMENT, PERFORMED PROCEDURE STEP AND DICOM PRINT. PN/CN: H45021E CLIN 0006 MPEGVUE ALLOWS EXPORT OF MPEG4-COMPRESSED RECORDS WITH HIGH QUALITY AND SMALL FILE SIZE, WORKSHEETS AND REPORTS ONTO LOCAL STORAGE MEDIA OR A REMOTE IP ADDRESS NETWORKED TO THE SYSTEM. THE MPEGVUE PLAYER CAN BE INSTALLED ON ANY STANDARD PC SY STEM. IT ENABLES FLEXIBLE REVIEW AND SIMPLE MEASUREMENTS OF HIGH-QUALITY IMAGES. THE SEND EMAIL TRANSPARENTLY SENDS PATIENT RECORDS VIA RESIDENT OUTLOOK CLIENT TO REMOTE DISTINATION. RECORDS ARE ENCRYPTED, ZIPPED AND PASSWORD-PROTECTED FOR SECURTIY. LONG ATTACHMENTS ARE QUTOMATICALLY DIVIDED INTO SMALLER ONE SENT WITH CONSECUTIVE EMAIL MESSAGES. MPEGVUE ON THE RECEIVING AND RETRIEVES ALL INCOMING OUTLOOK ATTACHMENTS WITH THE GET EMAIL OPTION AND RECOVERS THE ORIGINAL RECORD FOR REVIEW. PN/CN: H45021F CLIN 0007 LAN OPTICAL ISOLATION BOX IS REQUIRED FOR WIRED NETWORK INTERFACE WHEN THE SYSTEM IS CONNECTED TO THE PATIENT. PN/CN: H45021EC CLIN 0008 VIVID I ENGLISH LANGUAGE SUPPORT- USA. PN/CN: H45021H (vi) Description of requirements for the items to be acquired: Electrical Requirements 220V/50Hz; 2 copies each of Operator and Maintenance/Service Manuals in English Language; Display, Control Labels and ALL Software Version Copies must be in Engl ish L anguage for operating and subsystem components. (vii) The place(s) of delivery and acceptance will be U.S. Hospital Landstuhl, 66849 Landstuhl, Germany. All offerors must quote FOB Destination, Landstuhl Regional Medical Center, Landstuhl, Germany. (vi ii) The following Clauses and Provisions apply to this requirement: FAR 52.204-7. Central Contractor Registration; FAR 52.212-1, Instructions to Offerors -- Commercial Items applies to this acquisition; (ix) FAR 52.212-2 is not used. Award will be mad e to the technically acceptable low responsible offer. (x) Include a completed copy of the provision at 52.212-3, Alt I, Offeror Representations and Certifications -- Commercial Items, with your offer or complete paragraph (j) of 52.212-3 Alt 1, if the of feror has completed the annual representations and certifications electronically at http://orca.bpn.gov . (xi) FAR 52.212-4, Contract Terms and Conditions -- Commercial Items; (xii) FAR 52.212-5, Contract Terms and Conditions Required To Implement Stat utes Or Executive Orders -- Commercial Items; additional FAR clauses cited in the clause are: 52.222.19, Child Labor-Corporation with Authorities and Remedies (E.O.13126); 52.225-13 Restrictions on Certain Foreign Purchases; 52.232-33, Payment by Electro nic Funds Transfer Central Contractor Registration ; DFARS 252.212-7001, Contract Terms and Conditions Required To Implement Statutes Or Executive Orders Applicable to Defense Acquisition of Commercial Items, applies to this acquisition. Additional FAR cl auses cited in the clause are: 252. 232-7003, Electronic Submission of Payment Requests. (xiii)Additional contract requirement(s) or terms and conditions: Warranty statement will be provided in English. (xiv) Defense Priorities and Allocations Syste m (DPAS) is not applicable to this acquisition. (xv) Numbered Notes: None applicable. In order to be eligible for award, registration in the Central Contractor Registration database is required. To register, please go to http://www.ccr.gov. (xvi) Al l offers are due 25 JULY 07 before 1700hrs (5:00pm) Central European Time. Offers may be sent via email at to thelma.walker@amedd.army.mil, hand-delivered, or faxed to +49-6371-86-8070. (xvii) The Point of Contact for this requirement is Thelma Walker, +49-6371-86-7043, fax +49-6371-86-8070, or email thelma.walker@amedd.army.mil
- Place of Performance
- Address: European Regional Contracting Office ATTN:MCAA E, Building 3705 Landstuhl, Germany APO AE
- Zip Code: 09180
- Country: GE
- Zip Code: 09180
- Record
- SN01342161-W 20070715/070713221617 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)