Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 16, 2007 FBO #1997
SOLICITATION NOTICE

61 -- RESTACK, LAM INATION

Notice Date
5/14/2007
 
Notice Type
Solicitation Notice
 
NAICS
335312 — Motor and Generator Manufacturing
 
Contracting Office
Department of the Navy, Naval Supply Systems Command, Fleet and Industrial Supply Center Jacksonville, Kings Bay Det, 930 USS Hundley, Bldg 2012 Naval Submarine Base, Kings Bay, GA, 31547, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
Reference-Number-N444667111BX01
 
Response Due
5/24/2007
 
Archive Date
6/8/2007
 
Description
THIS IS A COMBINED SYNOPSIS/SOLICITATION FOR COMMERICAL ITEMS PREPARED IN ACCORDANCE WITH THE FORMAT IN SUBPART 12.6, AS SUPPLEMENTED WITH ADDITIONAL INFORMATION INCLUDED IN THIS PROPOSALS ARE BEING REQUESTED AND A WRITTEN SOLICITATION WILL NOT BE ISSUED. THE SOLICITATION NUMBER N444667111BX01 IS ISSUED AS A REQUEST FOR QUOTE (RFQ). THIS SOLICITATION DOCUMENT AND INCORPORATED PROVISIONS AND CLAUSES ARE THOSE IN EFFECT IS ISSUED ON A UNRESTRICTED BASIS. THE GOVERNMENT ATENT TO AWARD THIS CONTRACT TO JASPER ELECTRIC MOTOR INC. ON A SOLE SOURCE BASES. SIC CODE 7694, NAICS CODE 335312. TRIDENT REFIT FACILITY, NAVAL SUBMARINE BASE, KINGS BAY GA REQUIRES: (SEE STATMENT OF WORK) Restacking and/or re-laminating of a; General Dynamics/Electro Dynamic 70 KW Motor/Generator set Manufactures Dwg #; 9258358-1 Motor data Hp; 110 Frame; 580 Volts; 270, 210/355 VDC Amps; 325, 425/250 Winding type; Stabilized shunt/buck field Generator data 70 KW PF; .8 Volts; 120 VAC Phase; 3 F.L. Amps; 421 Receive the 70 KW frame and rotor from Trident Refit Facility. 1. Remove the generator stator core from the frame, dismantle the core to obtain measurements as required to manufacture a new generator stator core. Clean the frame prior to installation of the new stator core. Perform core loss test to new core. Install and secure the new core into the frame and perform final associated test. Note: stator core outside diameter; 25 INCH; bore, 21.475 INCH; core length, 9 INCH; slots, 144; sheet thickness, 0.014 INCH. QTY: 1 EA 2. Remove the exciter stator core from the frame, dismantle the core to obtain measurements as required to manufacture a new exciter stator core. Clean the frame prior to installation of the new stator core. Perform core loss test to new core. Install and secure the new core into the frame and perform final associated test. Note: exciter core diameter, 25 INCH; bore, 21.475 INCH; length, 1 INCH; slots, 28; sheet thickness, 0.014 INCH 1 EA 3. Remove the generator rotor core from the shaft, dismantle the core to obtain measurements as required to manufacture a new generator rotor core. Clean the rotor prior to installation of the new rotor core. Perform core loss test to new core. Install and secure the new core onto the shaft and perform final associated test. Note: generator iron diameter, 21.375 INCH; bore, 7 INCH; length, 8.9375 INCH; slots, 28; sheet thickness, 0.014 INCH. 1 EA 4. Remove the motor armature core from the shaft, dismantle the core to obtain measurements as required to manufacture a new motor core. Clean the rotor prior to installation of the new irons core. Perform core loss test to new core. Install and secure the new core onto the shaft and perform final associated test. Note: diameter, 13.5 INCH; bore, 6.65 INCH; length, 13.5INCH; slots, 50; sheet thickness, 0.025 INCH 1 EA Upon completion of work, package and crate the motor/generator frame, rotor assembly and all associated test data. Return completed components to Trident Refit Facility, Kings Bay, GA THE FOLLOWING PROVISIONS APPLY: 52.212-1 INSTRUCTIONS TO OFFERORS-COMMERCIAL; 52.212-3 OFFEROR REPRESENTATIONS AND CERTIFICATIONS-COMMERICAL ITEMS; 52.212-4 CONTRACAT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE ORDERS-COMMERCIAL ITEMS; 52.212-5 CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE ORDERS-COMMERCIAL ITEMS, AND CITING; 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.245-4 GOVERNMENT FURNISHED PROPERTY. 252.204-7004 CENTERAL CONTRACATOR REGISTRATION; 252.212-7001 CONTRACAT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES APPLICABLE TO DEFENSE ACQUISITONS OF COMMERCIAL ITEMS, AND CITING 252.225-7000; SEE NUMBER NOTE: 22. OFFERS ARE DUE BY CLOSE OF BUSINESS ON 24 MAY 2007 AND MAY BE FAXED TO 912-573-2191, FISC KINGS BAY GA. POC: JULIET BOHANNON 912-573-3800.
 
Place of Performance
Address: NAVAL SUBMARINE BASE, KINGS BAY BA,
Zip Code: 31547
Country: UNITED STATES
 
Record
SN01294392-W 20070516/070514221633 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.