MODIFICATION
49 -- Blast Booth (Beadblaster) and Paint Booth (Spray Booth) installation
- Notice Date
- 8/10/2006
- Notice Type
- Modification
- NAICS
- 327910
— Abrasive Product Manufacturing
- Contracting Office
- Department of the Air Force, Air Combat Command, 1st CONS, 74 Nealy Avenue, Suite 100, Langley AFB, VA, 23665
- ZIP Code
- 23665
- Solicitation Number
- Reference-Number-F2Q2016207A100
- Response Due
- 8/18/2006
- Archive Date
- 9/2/2006
- Small Business Set-Aside
- Total Small Business
- Description
- The purpose of this amendment is to post answers to all the questions that have been received. If requested photographs of the beadblaster and of the site will be provided along with drawings and specifications, interested party's must submit their requests to Mr. Kenneth Brumfiel. The drawings and specifications that will be provided are for official use only, they are only to be used for purposes of bidding on this project. Any and all information contained within these drawings and specifications shall not be disclosed to any other party without the permission of the government. These drawings and specifications are being provided for informational purposes only, they are not the final drawings. Answers to Questions: 1. Do you have all the original install drawings and maintenance manuals for this equipment? A- No, we have a parts breakdown manual for the bead blaster as opposed to an assembly manual. The paint booth will be built and designed by the contractor. 2. Because these units are bolt together, all NEW HARDWARE of the proper size will need to be provided by the government. A- No, the contractor will be responsible for providing all necessary hardware. 3. Are permits, sales tax or Bonds including AMQD permits required? A- Any and all applicable permits, bonding and sales tax are the responsibility of the contractor in accordance with local, state, and federal laws and regulations. No permits, sales tax or Bonds will be provided, including AMQD permits 4. Is the government providing the Drying Room? A- No, the contractor will provide the drying room 5. Why don't you have control panel for drying room? Do we need to provide it? A- The contractor will provide a control panel for the entire assembly-paint booth and drying room. We do not have the control panel because we do not have a paint booth/drying room 6. Paint Booth, Item # 2 Provide gas piping size and regulator size for AMU A- The gas piping size 2" and regulator size 29" with 5 psi. 7. Paint Booth, Item # 7, emergency exit lighting, installed where? over personnel doors inside or outside room, Battery powered? more detail needed. A- They should be inside over the personnel access doors, electrically powered with battery back up. 8. Item# 8, fire sprinkler system for Paint booth, drying room and blast booth? tie into building wet pipe system? or will a dry charged chemical stand-alone system be acceptable. A- Tie into the building wet pipe system 9. How far away are existing utilities for new install? concerns with gas piping and electrical power. A- Reference Beadblaster PDF file. The utility plan on sheet C-102 shows the water service; the site plan on sheet E-106 shows electric service. The mechanical floor plan on sheet M-101 shows the gas service entering the building but is not continued on the site plan. 10. As for a disabled veteran owned business will progress payments be offered? A- No, commercial contract progress payments will not be authorized. 11. Government will be responsible to replace all missing and damaged components, plus all new install hardware for assembly A- No hardware or components are currently missing from the bead blaster, the contractor will be responsible for all components and hardware 12. Contractor to supply and install the Paint Booth and Drying Chamber? A- Yes, this is one booth with a means to isolate drying chamber. 13. Does the unit have to be a PSI? What about approved equal? A- An approved equal spray booth will work. 14. Based on the requirement for exhaust stacks, we need to know the height inside your building from the floor to the underside of the roof structure, are there any obstructions or structure in the way? What type of roof? What is roof pitch? A- Reference Beadblaster PDF file and other PowerPoint document. The roof detail on sheet A-301 shows the roof to be a metal roof system with a 12-2 pitch. 15. In order to supply new sheet metal flooring and flat track rollers, we need the dimensions of the blast booth and the Name, address and phone number of the manufacturer. A- The manufacture is Clemco, phone number is 636-239-0300 , and address is 1 Cable Car Drive, Washington MO. 63090. The booth dimensions are 18' X 22'. 16. Model #. Date of manufacture, serial# etc, A- Make Clemco, Model# 7462-02, Manufacture Date 28 Dec 2002, and Serial # 35063 17. The booth is located at NASA Langley, will the contractor need to supply a forklift to load and unload the booth? A- Yes 18. How far away are existing utilities for new install? concerns with gas piping and electrical power. A- Reference PDF drawings. 19. Reserved. 20. In addition to the floor assembly with track, are you going to need new GRATING that sits on top of the floor system? A- NO 21. What is the job order number off of the Job order number off of the Aerolyte Blast equipment or manual? A- Job order number 7462-02. 22 . Clarify: Government specifications stated that they wanted an exhaust fan on a curb. A- We need an air make-up system to support paint booth that support temperature in SOW. The curb mentioned is for the ducting on the roof. 23. On the 3rd paragraph it states a Vane Axial fan & 2ea draft gauges. Which of these is the correct one that they want? A- We want the Vane Axail fan with 2 gauges or equivalent with 2 gauges that can produce the 125 FPM. 24. Where do they want those 2 draft gauges? There will be one gauge on the clean air side and one on the dirty air side. 25. In the past while installing paint booths for the Air Force, a 100FPM was dictated by the Air Force. A- The reason we?re showing 125 is to allow for enough air movement through filters and change filters once 100 FPM is reached. 100 FPM is the minimum requirement. 26. What type of roof is there where the exhaust fan goes out. Is it a built-up or a standing seam metal roof (metal). If it is a standing seal metal roof, what is the pitch? A- This questions was previously answered?.here is the response. Reference Beadblaster PDF file and other PowerPoint document. The roof detail on sheet A-301 shows the roof to be a metal roof system with a 12-2 pitch. The utility plan on sheet C-102 shows the water service; the site plan on sheet E-106 shows electric service. The mechanical floor plan on sheet M-101 shows the gas service entering the building but is not continued on the site plan. 27. Do you have a plan view of this installation? A- Reference Beadblaster PDF file and other PowerPoint document. 28. Does it show utilities (gas, electrical, air, water) and their location and capacity? A- Reference Beadblaster PDF file and other PowerPoint document. 29. Does it show the type of Sprinkler System and its capacity? A- Would need to meet Fire Department specifications. This can be brought up during the site visit. 30. Does it show the material flow in the area? A- Items would flow in and out of the booths through the door openings. 31. Do you have the Blast Booth where all the components can be viewed and checked during a site visit? A- Reference Beadblaster PDF file and other PowerPoint document. 32. Can you schedule a site visit? A- A site visit will be held on Tuesday August 15, 2006 at approximately 2pm to view the facility, the bead blaster will not be available for viewing, in accordance with FAR 52.237-1 Site Visit. If you plan on attending please notify this office by no later than August 11, 2006. 33. What is the access to the installation site? An escort will be provided, if you are interested please contact Mr. Kenneth Brumfiel at 757-764-5125 or at kenneth.brumfiel@langley.af.mil . 34. How secure is the area of the installation site? A- Access to the base is restricted to authorized personnel only, temporary passes will have to be issued to any contractor personnel. You will be escorted on to the facility.. 35. Equipment specs call for a certain booth. Can we use an equal to these? A- Yes 36. Do you want breathing air in the paint booth & Blast Booth. A- Bio-Environmental will require it. 37. Instead of a PSI paint booth will an equivalent be sufficient? A- Equivalent OK 38. We need to know the distance from the floor to the roof? A- Reference Beadblaster PDF file and other PowerPoint document. See attachment 39. Is there an offset in the ductwork? A- A site visit will be held on Tuesday August 15, 2006 at approximately 2pm to view the facility, the bead blaster will not be available for viewing. This can be brought up during the tour on Tuesday. 40. What are the maximum amps in the control panel where we will connect? Are there any open circuits---how many? & how fan from the paint booth, drying room? A- Reference Beadblaster PDF file and other PowerPoint document. See attachment. 41. We need the compressed air supply within 10' of the paint booth area. A- OK 42. Is the fire sprinkler above where the paint booth, drying room is located? A- Contractor will need to connect to facility sprinkler system for internal sprinklers in booth. 43. On page #3 it states that the duct goes up. Then it states they want a wall flashing? A- A site visit will be held on Tuesday August 15, 2006 at approximately 2pm to view the facility, the bead blaster will not be available for viewing. This can be brought up during the tour on Tuesday. 44. Also on page #3 it talks about a tunnel. What is this for? If this has to do with the drying room, why don't we just connect the drying room to the paint booth? A- The drying booth can be connected to the main booth (that?s what the tunnel is), and we need a door to separate both areas. That?s why we have more than one exhaust stack. 45. Do you want us to run CA & BA lines into the booth? A- As per SOW, we need two compressed air drops in the booth and a breathing air box with two connections.
- Place of Performance
- Address: Langley AFB, VA 23665
- Zip Code: 23665
- Country: UNITED STATES
- Zip Code: 23665