SOURCES SOUGHT
66 -- THERMAX 500 THERMOGRAVIMETRIC ANALYZER
- Notice Date
- 6/12/2006
- Notice Type
- Sources Sought
- Contracting Office
- 3610 Collins Ferry Road (MS-I07) P.O. Box 880 Morgantown, WV
- ZIP Code
- 00000
- Solicitation Number
- DE-RQ26-06NT00526
- Response Due
- 6/24/2006
- Archive Date
- 12/24/2006
- Small Business Set-Aside
- N/A
- Description
- DESCRIPTION: This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 13.5, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This solicitation number DE-RQ26-06NT00526 is issued as a Request for Quote (RFQ). This requirement is being issued as a Request for Quotation using Simplified Acquisition Procedures. The following items are to be purchased by the U.S. Department of Energy, National Energy Technology Laboratory (NETL), Pittsburgh, PA. Award will be made to the low priced, technically acceptable (equal) offeror. The following items are to be purchased and to be delivered at our site in Morgantown, WV. Equality shall be determined by the offered equipment???s compliance with the following performance requirements. Compliance will be determined by the offeror???s provision of literature showing performance capabilities or through written narrative discussing the points not covered by the published literature. 1. THERMMAX 500 HIGH PRESSURE TGA SYSTEM (OR EQUAL) WITH THE FOLLOWING SPECIFICATIONS: A. PRESSURE BALANCE. B. 110 DEGREES C FURNACE. C. PRESSURE CONTROL SYSTEM (INCL MASS FLOW CONTROLLERS, BACK PRESSURE REGULATOR, FLOW COILS, PRESSURE TRANSDUCER, FLOW SWITCHES, SOLENOID VALVES, ETC). D. PC SOFTWARE TO CONTROL HPTGA AND ACQUIRE/ANALYZE DATA. (NOTE: MUST HAVE WEIGH MEASUREMENT CAPABILITY AT 1500 PSI AT ROOM TEMPERATURE OR 1000 PSI AT 1000 DEGREES C USING QUARTZ REACTION TUBES. AT THESE PRESSURES AND TEMPERATURES, THE BALANCE AND SAMPLE CAPACITY IS 100 G WITH A READABILITY OF 1 MICROGRAM. THE UNIT WILL BE VACUUM READY TO O.0001 TORR). 1 EACH. 2. 1 YEAR CONSUMBALES KIT FOR THERMAX 500 TO INCLUDE THE FOLLOWING: *2 HANGDOWN ASSEMBLIES. *4 19-MM QUARTZ BUCKETS. *2 ALUMINA EXTENSION WIRES. *2 UPPER BAFFLE *1 LOWER BAFFLE *1 SST FORCEPS *2 COUPLING O-RINGS *2 FURNACE VESSEL O-RINGS *2 FURNACE TOP-PLATE O-RINGS *2 FURNACE VESSEL O-RINGS *1 K-TYPE THERMOCOUPLE *1 2-M EXTENSION WIRE 1 EACH 3. DELL OPTIPLEX GX260T SMALL MINI-TOWER (OR BETTER) WITH THE FOLLOWING SPECIFICATIONS: *P4 2.0 GHZ, 512K CACHE *256 MB, NONECC, 266 MHZ DDR. *DELL PS/2 KEYBOARD IN GREY *DELL M782 16??? VIEWABLE IMAGE MONITOR *32MB, ATI, RADEON 7500 VIDEO CARD *20 GB 7200 RPM HD *3.5???, 1.44 MB FLOPPY 1 EACH 4. Z65 COLOR JETPRINTER: *DELL COLOR DESKJET PRINTER (OR EQUAL) W/USB CABLE *Z65 COLOR JETPRINTER *4800X 1200 DPI *21 PPM B/W PRINT *15 PPM COLOR PRINT 1 EACH 5. INSTALLTION AND OPERATIONAL TRAINING 1 EACH. EVALUATION: The award will be made to the low priced, technically acceptable offer. An award shall be made to the responsible offeror submitting a technically acceptable quote and offering the lowest evaluated price. Evaluation is base on best value including cost and ability to meet stated requirements above. Offerors shall submit descriptive literature detailing features, technical capabilities and warranty data. Technical acceptability will be determined solely on the content and merit of the information submitted response to this provision as it compares to the minimum characteristics provided above. Therefore, it is essential that offerors provide sufficient technical literature, documentation, etc., in order for the Government evaluation team to make an adequate technical assessment of the quote as meeting technical acceptability. Compliance will be determined by the offeror???s provision of literature showing performance capabilities or through written narrative discussing the points not covered by the published literature. INTERESTED PARTIES SHALL SUBMIT OFFERS WITH THE FOLLOWING INFORMATION: Federal Tax Identification Number (TIN), Dun & Bradstreet Number (DUNS), and remit to address if different. The award shall be made using FAR 13, Simplified Acquisition Procedures. The North American Industry Classification (NAIC) is 334516. All bids, proposals, or quotations must be faxed to Mr. Robert L. Mohn ??? FAX 412-386-5770 by 5:00 PM Eastern Time, June 26, 2006. NO PHONE CALLS. All technical questions should be addressed to the Technical Representative for the above requirement who is Mr. ROBERT STEVENS AT 304-285-4305.
- Web Link
-
Click here for further details regarding this notice.
(https://e-center.doe.gov/iips/busopor.nsf/UNID/971DF165B5DEA7F48525718B005F5D80?OpenDocument)
- Record
- SN01067711-W 20060614/060612220228 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |