Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 03, 2006 FBO #1650
SOLICITATION NOTICE

Z -- Upgrade of Barracks Buildings 645, 646 and 648, Presidio of Monterey, Monterey County, California

Notice Date
6/1/2006
 
Notice Type
Solicitation Notice
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
US Army Engineer District, Sacramento, 1325 J. Street, Sacramento, CA 95814
 
ZIP Code
95814
 
Solicitation Number
W91238-06-R-0038
 
Response Due
7/20/2006
 
Archive Date
9/18/2006
 
Small Business Set-Aside
N/A
 
Description
PROJECT: Upgrade of Barracks Buildings 645, 646 and 648. LOCATION: Presidio of Monterey, Monterey County, California. TYPE OF AWARD: This acquisition is proceeding as an Unrestricted Request for Proposal (RFP). Large businesses competing for this project must comply with the FAR 52.219-9 Small Business Subcontracting Plan, regarding the requirement for a subcontracting plan on the part of the work it intends to subcontract. The recommended goals for subcontracting are: 51.2% for Small Businesses; 8 .8 for Small Disadvantaged Businesses; 7.3% for Women-Owned Small Businesses; 3.1% for HUBZone Businesses; and 1.5% for Service Disabled Veteran Owned Small Businesses. Estimated cost range is between $10,000,000.00 to $25,000,000.00. This procurement wi ll be conducted under FSC Code: Z199; SIC Code: 1522; NAICS Code: 236220. The small business size standard for this code is $31,000,000. Information about the time and location of the site visit/preproposal conference will be found in Section 00100 of th e solicitation, clause 52.236-27. All questions should be directed to the Contract Specialist - Brad Heath at (916) 557-5227 or Brad.A.Heath@usace.army.mil. JOB DESCRIPTION: Renovate Barracks Buildings 645, 646 and 648 (1985-1988 vintage) in order to bri ng them up to a modified 1+1 configuration. Work entails the reconfiguration of 44 existing rooms (in each building) to provide suites of two semi-private sleeping rooms and one private sleeping room, each with its own built-in closet(s). The reconfigu ration will provide one shared bath and service area and one private bath and service area. Work also includes replacing interior wall finishes, replacing ceilings, replacing flooring, installing/replacing lighting throughout each building, upgrading the HVAC system, replacing the plumbing system, upgrading the electrical system, installing/replacing the fire detection system and installing a new fire sprinkler system. The RFP for this project will be issued on or around 15 June 2006 and offers are an ticipated to be due on or about 20 July 2006. Plans and specifications will not be provided in hard paper copy or CD-ROM format. The solicitation and all amendments for this acquisition will be posted on a secure Government website known as FedTeDS. Acc ess to the RFP documents on the FedTeDS website will be via a hyperlink. The hyperlink will be inserted into the notices for this acquisition posted on both the Army Single Face to Industry (ASFI) website (https://acquisition.army.mil/asfi/) and the FedBi zOpps website (www.fbo.gov) once the RFP is issued. The hyper-link will not appear as a website address, but text as follows: Available online via the FedTeDs (Federal Technical Data Solution) website. Viewing/downloading documents from FedTeDS will req uire prior registration in Central Contractor Registration (www.ccr.gov). If you are a first-time FedTeDS user, you will also be required to register in FedTeDS (www.fedteds.gov) before accessing the IFB documents. To register, click on the Register with FedTeDS hyperlink, then select the Begin Vendor/Contractor Registration Process option. The following information will be required: Central Contractor Registration (CCR) Marketing Partner Identification Number (MPIN); DUNS Number or Cage Code; Telephone Number; and E-mail Address. Once registered with FedTeDS, interested parties will then be able to utilize the posted hyperlink to log in and access the RFP documents. Important Note: Solicitation documents can be accessed ONLY by using the hyperlink avai lable on either FBO or ASFI; FedTeDS is not searchable by any other means. Please note that ALL contractors who want to register with FedTeDS must be CCR registered, and have a MPIN, DUNS number or Cage code. For further information, please click on the FedTeDS homepage links; FAQs, Vendor User Guide, and FedTeDS Help. For additional assistance with the FedTeDS website, contact the Ogden Electronic Business (E B) Operations Support Team (OST) at 866-618-5988 (toll free), 801-605-7095, or cscassig@ogden.disa.mil (subject: FedTeDS Assistance). IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK FedTeDS FREQUENTLY FOR ANY AMENDMENTS OR CHANGES TO THE RFP. See Num bered Note 9.
 
Place of Performance
Address: US Army Engineer District, Sacramento 1325 J. Street, Sacramento CA
Zip Code: 95814
Country: US
 
Record
SN01060778-W 20060603/060601221032 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |