Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 01, 2006 FBO #1587
SOLICITATION NOTICE

58 -- FY 06-FY10 Depot Repair of the Horizontal Technology Integration (HTI) 2nd Generation Forward Looking Infrared (FLIR) program

Notice Date
3/30/2006
 
Notice Type
Solicitation Notice
 
NAICS
334511 — Search, Detection, Navigation, Guidance, Aeronautical, and Nautical System and Instrument Manufacturing
 
Contracting Office
US Army C-E LCMC Acquisition Center - DAAB07, ATTN: AMSEL-AC, Building 1208, Fort Monmouth, NJ 07703-5008
 
ZIP Code
07703-5008
 
Solicitation Number
W15P7T06RM219
 
Response Due
4/25/2006
 
Archive Date
6/24/2006
 
Small Business Set-Aside
N/A
 
Description
The U.S. Army Communications  Electronics Life Cycle Management Command and Program Manager, Night Vision  Reconnaissance, Surveillance, and Target Acquisition is conducting a market survey. The Government intends to solicit in the near future for the FY 06-FY10 Depot Repair of the Horizontal Technology Integration (HTI) 2nd Generation Forward Looking Infrared (FLIR) program. The proposed acquisition is for award of a 5 Year  Multiple Year contract for HTI Night Vision (NV)-80 Block 0 and Block 1 B-Kits. For the purpose of this document, these items will henceforth be referred to as FLIR assemblies. The HTI NV-80 B-Kits enable the insertion of a standard thermal sensor into the Armys highest priority ground based platforms through the use of veh icles sight-unique integration components called A-Kits. a. Description and Application The purpose of this procurement is to acquire Non-Warranty Depot Repair services for the HTI Night Vision FLIR Assemblies to meet the Operational Readiness needs of the warfighter. HTI NV-80 B-Kit  There are two configurations of the HTI NV-80 B-Kit to be procured: Block 0 and Block 1. Both Block 0 and Block 1 B-Kits consist of a Sensor Unit (SU), containing an Afocal, an Imager, and a Detector Cooler Bench Assembly. The Block 1 B-Kit also contains four Circuit Card Assemblies (CCA); while the Block 0 B-kit contains nine CCAs and a Common Electronics Unit (CEU). The Govt wishes to procure Depot Repair services for the Block 0 and Block 1 B-Kit and as part of a Performance Based Logistics (PBL) initiative may be willing to provide incentives for quicker repair Turn around Time (TAT). On previous contracts the non -warranty repair TAT has been set at 60 days. The Govt will pay incentives for each B-Kit item returned to service sooner than 30 days but will charge the contractor fees for items returned to service over the 60 day limit. The incentives and fees have yet to be determined. b. Performance Requirements The following list contains all of the performance specifications that the supplier will need to meet to be considered fully qualified for each of the items. MIL-PRF-A3207380 Performance Specification for the Block 0 B-Kit MIL-PRF-A3271804 (NC 2/28/2005) Performance Specification for the Block 1 B-Kit c. Interface Control Documents. The following list contains all of the Interface Control Drawings (ICD) that the HTI NV-80 B-Kit supplier will need to meet to be considered fully qualified. A3271784 Interface Control Document (ICD) for the Horizontal Technology Integration (HTI) Program Block 0 B-Kit A3298946 (C 2/28/2005) Interface Control Document (ICD) for the Horizontal Technology Integration (HTI) Program Block 1 B-Kit This is a market survey to identify all parties interested in taking part in this entire effort as a prime contractor. Please provide the following information no later than 25 April 2006. Note the Government does not own a technical drawing package for t his effort. " Brief summary of the company " Qualifications in Thermal Imaging/Infrared Technology for this effort or like efforts. " Describe how you will meet the required base repair TAT of 60 days and what you will do in an effort to ship items early. Send responses to: PM FLIR ATTN: SFAE-IEWS & S-NV-FLIR 10221 Burbeck Road Fort Belvoir, VA 22060-5806 ATTN: Jody R. McCourt And a copy to the Contracting Officer: Kathleen H. Rizzo AMSEL-AC-CC-RT-F(HIE) Bldg 1208 Ritko Ave Fort Monmouth, NJ 07703 ATTN: Michael Hier
 
Place of Performance
Address: US Army C-E LCMC Acquisition Center - DAAB07 ATTN: AMSEL-AC-CC-RT-F(HIE), Building 1208 Fort Monmouth NJ
Zip Code: 07703-5008
Country: US
 
Record
SN01018188-W 20060401/060330212728 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.