MODIFICATION

N -- Remove and replace SF6 72.5 KV circuit breakers

Notice Date
12/19/2005
 
Notice Type
Modification
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
Department of the Air Force, Air Force Space Command, 30CONS, Bldg 7015, Section 2C 806 13th Street, Ste 2, Vandenberg AFB, CA, 93437-5226
 
ZIP Code
93437-5226
 
Solicitation Number
Reference-Number-F4D3D95290A200
 
Response Due
1/6/2006
 
Point of Contact
Darian Soares, Contract Specialist, Phone (805) 606-6367, Fax (805) 606-5867, - Celeste Cappomagi, Contracting Officer, Phone 805-606-2515, Fax 805-922-1703,
 
E-Mail Address
darian.soares@vandenberg.af.mil, celeste.cappomagi@vandenberg.af.mil
 
Small Business Set-Aside
Total Small Business
 
Description
This amendment is to extend the due date for quotes for F4D3D95290A200 Remove and Replace SF6 72.5 KV circuit breaker and to inform interested parties of viewing times for the “As Built” drawings and circuit breaker manual. Quotes are now required to be received no later than 2:00 P.M. PST, Friday, January 06, 2006. All quotes must be sent to Darian Soares at : Fax 805-606-5867 : darian.soares@vandenberg.af.mil ; 30 CONS Attn: Darian Soares Bldg 7015 Sec 2C Vandenberg AFB Ca. 93437. The “As Builts” for the sub-station, circuit breaker manual, Bushing information, and Swith installation instructions will be available to view Tuesday through Thursday from 8:00 A.M until 4:00 P.M. PST. Starting 20 December 2005 and ending 05 January 2006. Viewing location is building 7015, Sec 2C, cubicle 42, Vandenberg AFB Ca. 93437. uested and a written solicitation will not be issued. This combined synposis/solicitation is issued as a request for quote (RFQ) F4D3D95290A200. Submit written offers only, oral offers will not be accepted. All firms or individuals responding must be registered with the Central Contractor Registration (CCR). This procurement is being issued as 100% SMALL BUSINESS SET-ASIDE. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-06 and DFARS Change Notice 20040625. North American Industrial Classification Standard 811310, Size Standard, $6,000,000.00, applies to this procurement. FOB: Destination for delivery: Facility 7315, Vandenberg AFB CA 93437 .The following provisions and clauses apply to this acquisition: FAR 52.212-1, Instructions to Offerors--Commercial Items. Quotes will be evaluated on price related factors only. The provision at FAR 52.212-3, Offeror Representations and Certifications -- Commercial Items, and the offeror must include a completed copy of this provision with their proposal. The clause at FAR 52.212-4, Contract Terms and Conditions-Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders--Commercial Items. Specifically, the following clauses cited are applicable to this solicitation: FAR 52.222-26, Equal Opportunity; FAR 52.222-35, Affirmative Action for Disabled Veterans and Veterans of the Vietnam Era; FAR 52.222-36, Affirmative Action for Handicapped Workers; FAR 52.222-37, Employment Reports on Disabled Veterans and Veterans of the Vietnam Era. The clause at FAR 52.224-1, Privacy Act Notification and FAR 52.224-2, Privacy Act; FAR 52.232-33, Payment by Electronic Funds-Central Contractor Registration. The clause at DFARS 252.204-7004, Required Central Contractor Registration; DFARS 252.212-7001, Contract Terms and Conditions Required to Implement Statues or Executive Orders; DFARS 252.225- 7001, Buy American Act and Balance of Payment Program; AAFARS 5352.201-9101, Ombudsman. A site visit will be held on 14 Nov 2005 at 9:00 A.M. PST. It is advised that all interested parties attend this site visit. Please send me the names of the people who will be attending the site visit, by email or fax, by 2:00 P.M. PST on 11 Nov 2005. Any questions will need to be submitted in writing by 2:00 P.M. PST on 16 Nov 2005. The answers will be posted on the eps website by 21 Nov 2005. All quotes must be sent to Darian Soares at : Fax 805-606-5867; darian.soares@vandenberg.af.mil; 30 CONS Attn: Darian Soares Bldg 7015 Sec 2C Vandenberg AFB CA 93437. Quotes are required to be received no later than 2:00 PM PST, Friday, November 25, 2005. Questions and answers for F4D3D95290A200 Q) What size conductors is the SF6 circuit breaker tied onto? A) The conductors size is 397.5 kcmil Q) The SF6 Gas is being provided by Exterior Electric shop, does this mean they are installing the gas in the SF6 circuit breaker? A) The Exterior Electric shop will provide the SF6 gas only. The contractor will be required to install gas. Q) What is to be done with the old Siemens circuit breaker? A) The contractor shall deliver the old Siemens breaker to the Exterior Electric shop storage facility. Q) What is the footage between the junction box for the control wires and circuit breaker teminals? A) The footage from the junction box is approximately 15 feet. Q) Can we get a wiring interconnection sheet? A) Yes, a interconnection wiring sheet can be sent to you via email or fax if requested. Q) What is the project duration? A) Project duration is approxametly 10 days. Q) Is there a period where the contractor will not be able to access the substation due to base activites such as launches, etc? A) The sub station is located on main base and should not be affected by launches but the possibility exist although none are forseen at this time. Q) Can I obtain a copy of the new SF-6 breaker manual? A) Yes a copy of the manual is online at www.abb.com Q) Are there plans and specs for this project? A) Not at this time. Q) If there are no plans and specs for this project are there “As Builts” to the existing sub station? A) There will be a second site visit scheduled for 28 Nov 2005 at 9:00 A.M. PST. The “As Builts” will be onsite for interested parties to view at that time. NOTE: THIS NOTICE MAY HAVE POSTED ON FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (19-DEC-2005). IT ACTUALLY APPEARED OR REAPPEARED ON THE FEDBIZOPPS SYSTEM ON 23-JAN-2006, BUT REAPPEARED IN THE FTP FEED FOR THIS POSTING DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.fbo.gov/spg/USAF/AFSC/30CONS/Reference-Number-F4D3D95290A200/listing.html)
 
Place of Performance
Address: Building 7315 Vandenberg AFB, CA.
Zip Code: 93437
 
Record
SN00971757-F 20060125/060123213650 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.